Electric Powered Turntable
constitute EMC Test Systems, L.P.
assuming any liability whatsoever arising out of the application or use of any product or circuit described
herein. EMC Test Systems, L.P. does not convey any license under its patent rights or the rights of others.
© Copyright 2002 by EMC Test Systems, L.P. All Rights Reserved.
No part of this document may be copied by any means
without written permission from EMC Test Systems, L.P.
E-MAIL & INTERNET
Support@ets-lindgren.com
http://www.ets-lindgren.com
USA
1301 Arrow Point Dr., Cedar Park, TX 78613
P.O. Box 80589, Austin, TX 78708-0589
Tel 512.531.6400 Fax 512.531.6500
FINLAND
Euroshield OY
Mekaanikontie 1
27510, Eura, Finland
Tel 358.2.838.3300
Fax 358.2.865.1233
SINGAPORE
Lindgren RF Enclosures Asia-Pacific
87 Beach Road
#06-02 Chye Sing Building
Singapore 189695
Tel 65.536.7078 Fax 65.536.7093
MODEL 2087 TURNTABLE SERIES
© EMC TEST SYSTEMS, L.P. OCTOBER 2002
REV C PN 399233
Table of Contents
INTRODUCTION.................................................................................................................................. 1
STANDARD CONFIGURATION ......................................................................................................... 2
OPTIONS ............................................................................................................................................... 3
PRECAUTIONS..................................................................................................................................... 5
TURNTABLE INSTALLATION CONSIDERATIONS ....................................................................... 6
P
OWER AND
S
IGNAL
L
INES
.................................................................................................................... 6
O
UTDOOR
I
NSTALLATIONS
.................................................................................................................... 6
ASSEMBLY INSTRUCTIONS.............................................................................................................. 7
G
ROUND
R
ING
I
NSTALLATION
............................................................................................................... 8
ELECTRICAL INSTALLATION ......................................................................................................... 9
C
ONNECTING THE
M
ODEL
2090 P
OSITIONING
C
ONTROLLER
................................................................. 10
SETTING TRAVEL LIMITS .............................................................................................................. 11
OPERATION ....................................................................................................................................... 13
R
ECOMMENDED
P
ARAMETERS FOR THE
M
ODEL
2090 P
OSITIONING
C
ONTROLLER
................................. 14
E
DITING
M
ODEL
2090 P
OSITIONING
C
ONTROLLER
C
ONFIGURATION
P
ARAMETERS
................................ 14
T
URNTABLE
E
NCODER
C
ALIBRATION
................................................................................................... 15
TT C
ALIBRATION
E
XAMPLE
................................................................................................................ 16
S
ETTING
C
URRENT
P
OSITION
O
N
2090 ................................................................................................. 17
C
AUTION
: O
N
R
ESETTING
C
URRENT
P
OSITION
O
N
2090 ....................................................................... 17
HAND CONTROL UNIT..................................................................................................................... 18
RECOMMENDED MAINTENANCE................................................................................................. 19
E
VERY
S
IX
M
ONTHS
............................................................................................................................ 19
E
VERY
12 M
ONTHS
............................................................................................................................. 19
SPECIFICATIONS .............................................................................................................................. 20
E
LECTRICAL
....................................................................................................................................... 20
M
ECHANICAL
...................................................................................................................................... 20
WARRANTY STATEMENT............................................................................................................... 21
ILLUSTRATIONS ............................................................................................................................... 22
MODEL 2087 TURNTABLE SERIES
© EMC TEST SYSTEMS, L.P. OCTOBER 2002
REV C PN 399233
NOTICE: This product and related documentation must be reviewed for familiarization
with safety markings and instructions before operation.
SAFETY SYMBOL DEFINITIONS
GENERAL SAFETY CONSIDERATIONS
REFER TO MANUAL When product is marked with this symbol refer to
instruction manual for additional information.
HIGH VOLTAGE Indicates presence of hazardous voltage. Unsafe practice
could result in severe personal injury or death.
PROTECTIVE EARTH GROUND (SAFETY GROUND)
Indicates protective earth terminal. You should provide uninterruptible safety
earth ground from the main power source to the product input wiring
terminals, power cord, or supplied power cord set.
CAUTION Denotes a hazard. Failure to follow instructions could result in
minor personal injury and/or property damage. Included text gives proper
procedures.
WARNING Denotes a hazard. Failure to follow instructions could result in
SEVERE personal injury and/or property damage. Included text gives proper
procedures.
BEFORE POWER IS APPLIED TO THIS INSTRUMENT,
GROUND IT PROPERLY through the protective conductor of the AC power
cable to a power source provided with protective earth contact. Any
interruption of the protective (grounding) conductor, inside or outside the
instrument, or disconnection of the protective earth terminal could result in
personal injury.
BEFORE SERVICING: CONTACT ETS-LINDGREN - servicing
(or modifying) the unit by yourself may void your warranty. If you attempt to
service the unit by yourself, disconnect all electrical power before starting.
There are voltages at many points in the instrument which could, if
contacted, cause personal injury. Only trained service personnel should
perform adjustments and/or service procedures upon this instrument.
Capacitors inside this instrument may still be CHARGED even when
instrument is disconnected from its power source.
ONLY QUALIFIED PERSONNEL should operate (or service) this equipment.
STAY CLEAR of moving components during operation of equipment.
!
CAUTION
WARNING
WARRANTY
OR
MODEL 2087 TURNTABLE SERIES
Introduction
© EMC TEST SYSTEMS, L.P. OCTOBER 2002
1
REV C PN 399233
INTRODUCTION
The ETS-Lindgren Model 2087 is an electric powered turntable
platform system designed to be used with the Model 2090
Positioning Controller for EMI compliance testing. The Model
2087 is available in 2.03 and 3.03 meter sizes, both designed for
indoor or outdoor use.
The sectional turntable top surface is made of aluminum. The
conductive metal top is fitted with a ground brush to electrically
couple the turntable to the ground plane. The brush provides
continuous contact with the floor flange supplied. To extend the
life of the ground brush, a one-piece stainless steel liner is attached
to the inside edge of the stationary floor flange.
Both models utilize a pinion and gear drive with a gear reducer and
electric motor located beneath the platform. The bearing on which
the turntable rotates has the drive teeth cut directly on the outside
and will easily support most Equipment Under Test (EUT).
Support for the turntable includes casters that aid in the support of
cantilevered loads on the outside of the turntable.
The turntable top is sectional to provide easy access if service is
required. On standard models, a 15 cm hole is provided in the
center of the turntable to accommodate customer supplied cabling
to and from the EUT. This hole also provides access to the limit
switch adjustment knobs and the primary circuit breaker.
To prevent over-travel of the turntable in either direction of
movement, mechanical limits can be adjusted. The limit switch
adjustments are on the encoder/limit assembly which is located
below the turntable top. For continuous rotation without limits,
adjustments can be made in the encoder/limit assembly. Soft limits
can be set within the mechanical limits, using the Model 2090
positioning controller. Signal I/O between the turntable and
positioning controller is provided by fiber-optic control lines.
Standard Configuration
MODEL 2087 TURNTABLE SERIES
2
© EMC TEST SYSTEMS, L.P. OCTOBER 2002
REV C PN 399233
STANDARD CONFIGURATION
Turntable assembly
Ground ring assembly with ground brush and floor flange
230 VAC Electric Motor Unit
Rotational limit adjust switches
Continuous or Non-continuous operation
Ten-meter fiber-optic control ca