P Q - 1 0 0

thors of this page or responsible for its content.
P Q - 1 0 0 100W Quad Output Switching Power Supply
SPECIFICATION
PQ-100B
PQ-100C
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
WORKING TEMP.
POWER GOOD
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVER LOAD
AC CURRENT (Typ.)
5V
CH1
CH1
-5V
CH3
CH3
12V
CH2
CH2
-12V
CH4
CH4
5V
-5V
15V
-15V
10A
0.5A
3.5A
0.5A
8A
0.5A
3.5A
0.5A
2 ~ 10A
0 ~ 1A
0.5 ~ 4.5A
0 ~ 1A
2 ~ 8A
0 ~ 1A
0.5 ~ 4A
0 ~ 1A
100.5W
102.5W
80mVp-p
80mVp-p
250mVp-p
120mVp-p
80mVp-p
150mVp-p
150mVp-p
80mVp-p
CH1:4.75 ~ 5.5V
CH1:4.75 ~ 5.5V
3.0%
6.0%
12%
6.0%
6.0%
6.0%
6.0%
2.0%
1.0%
2.0%
1.0%
1.0%
1.0%
1.0%
1.0%
3.0%
1.0%
1.0%
1.0%
1.0%
5.0%
5.0%
1.0%
5.0%
1200ms, 50ms at full load
80ms at full load
100 ~ 264VAC
141 ~370VDC (90 ~ 100VAC 90% load max.)
47 ~ 63Hz
72%
74%
3A/115VAC
1.5A/230VAC
COLD START 50A
<1mA /240VAC
105% ~ 135%
rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +50
,60
(Refer to output load derating curve)
with cooling fan
1ms
20 ~ 90% RH non-condensing
-20
~ +85
, 10 ~ 95% RH
0.03%/
(0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X, Y, Z axes
258.6K hrs min.
MIL-HDBK-217F (25
)
177.8*107.95*46mm (L*W*H)
0.56Kg; 24pcs/14.5Kg/1.19CUFT
File Name:PQ-100-SPEC 2006-02-14
CH1: 5.75 ~ 6.75VDC
OVER VOLTAGE
SAFETY STANDARDS
HARMONIC CURRENT
EMS IMMUNITY
UL60950-1,
TUV EN60950-1 Approved
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to
Light industry level, criteria A
EN61000-4-2,3,4,5,6,11; ENV50204,
Features :
P Q - 1 0 0
s e r i e s
ENVIRONMENT
SAFETY &
FUNCTION
EMC
(Note 4)
PROTECTION
EMI CONDUCTION & RADIATION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
Universal AC input / Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
With power good signal output(Optional)
100% full load burn-in test
Fixed switching frequency at 45KHz
2 years warranty
OUTPUT NUMBER 100W Quad Output Switching Power Supply
SPECIFICATION
PQ-100D
PQ-100E
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
WORKING TEMP.
POWER GOOD
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVER LOAD
AC CURRENT (Typ.)
5V
24V
12V
-12V
5V
15V
12V
24V
5A
2A
2A
0.5A
8A
0.6A
3A
0.6A
2 ~ 5A
0.4 ~ 2A
0.5 ~ 4.5A
0 ~ 1A
2 ~ 8A
0 ~ 1A
0.5 ~ 3A
0 ~ 1A
103W
99.4W
80mVp-p
180mVp-p
120mVp-p
120mVp-p
150mVp-p
120mVp-p
120mVp-p
80mVp-p
CH1:4.75 ~ 5.5V
CH1:4.75 ~ 5.5V
2.0%
10%
6.0%
6.0%
6.0%
6.0%
6.0%
2.0%
1.0%
1.0%
1.0%
5.0%
1.0%
1.0%
1.0%
3.0%
1.0%
1.0%
1.0%
1.0%
5.0%
3.0%
1.0%
5.0%
1200ms, 50ms at full load
80ms at full load
100 ~ 264VAC
141 ~370VDC (90 ~ 100VAC 90% load max.)
47 ~ 63Hz
77%
74%
3A/115VAC
1.5A/230VAC
COLD START 50A
<1mA /240VAC
105% ~ 135%
rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +50
,60
(Refer to output load derating curve)
with cooling fan
1ms
20 ~ 90% RH non-condensing
-20
~ +85
, 10 ~ 95% RH
0.03%/
(0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X, Y, Z axes
258.6K hrs min.
MIL-HDBK-217F (25
)
177.8*107.95*46mm (L*W*H)
0.56Kg; 24pcs/14.5Kg/1.19CUFT
File Name:PQ-100-SPEC 2006-02-14
CH1: 5.75 ~ 6.75VDC
OVER VOLTAGE
SAFETY STANDARDS
HARMONIC CURRENT
EMS IMMUNITY
UL60950-1,
TUV EN60950-1 Approved
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to
Light industry level, criteria A
EN61000-4-2,3,4,5,6,11; ENV50204,
Features :
P Q - 1 0 0
s e r i e s
ENVIRONMENT
SAFETY &
FUNCTION
EMC
(Note 4)
PROTECTION
EMI CONDUCTION & RADIATION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
Universal AC input / Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
With power good signal output(Optional)
100% full load burn-in test
Fixed switching frequency at 45KHz
2 years warranty
OUTPUT NUMBER
CH1
CH1
CH3
CH3
CH2
CH2
CH4
CH4 File Name:PQ-100-SPEC 2006-02-14
Unit:mm
DC Output Connector (CN2) : Molex 5273-06,07 or equivalent
Pin No.
1,2,3
4,5,6,7
8,9
10
11
12
13
Assignment
V1
COM
V2
Power Good(Option)
V3
No Pin
V4
Mating Housing
Molex 5195
or equivalent
Terminal
Molex 5194
or equivalent
AC Input Connector (CN1) : Molex 5273-05 or equivalent
Pin No.
1
2,4
3
5
Assignment
Mating Housing
Molex 5195
Molex 5194
or equivalent
or
equivalent
Terminal
L
O
A
D(
%
)
Mechanical Specification
Static Characteristics (B)
Output Derating
AMBIENT TEMPERATURE (
)
(HORIZONTAL)
-10
-10
0
0
10
20
30
40
50
60
20
40
60
80
100
INPUT VOLTAGE (V) 60Hz
90
100
110
120
140
160
180
200
220
240
260
300
250
200
150
100
50
25
O
U
T
P
U
TV
O
L
T
A
G
E(
V
)
O
U
T
P
U
TR
I
P
P
L
E(
m
V
p
-
p
)
Ta=25
12
13
8
7
11
10
9
4.8
5.0
5.2
4.4
4.6
4.2
4.0
17CFM forced air cooling(20cm)
Natural convection cooling
100W Quad Output Switching Power Supply
177.8
165.1
1
0
7
.
9
5
9
5
.
2
5
1
CN2
+5V ADJ
4
3
2
6
5
9
8
7
11
10
CN1
1
13
3
T4A/250V
5
4-
3.96
4
6
12
2
4
12V
5V
5V
+12V
-12V
6.35
6
.
3
5
FG
No Pin
AC/N
AC/L
P Q - 1 0 0