Spark Detection and Extinguishment
nguishment
Systems protect against
dust fires and explosions
in pneumatic conveying
and exhaust systems.
Sparks and other sources
of ignition are detected
and extinguished
immediately - before they
reach the filter media.
Production is
uninterrupted, equipment
damage is reduced, and
personnel injuries from
fires and explosions are
eliminated.
CC-700
A streamline, low cost version of the
CC-701. Single zone console,
motherboard construction; 1 or 2
sensors; non-expandable; LED
information display. NEMA 12. (Not
FM Approved.)
PART#
ITEM
581607
CC-700 Console
Control
Consoles
GreCon Control Consoles receive
and process signals from sen-
sors, and automatically activate
individually controlled counter-
measures including: extinguish-
ment, deluge, abort, or auto-
matic machinery shutdown.
Console enclosures are IP55*
(NEMA 4), suitable for severe
industrial surroundings. Menus
display all functions and test
procedures for the console,
sensors and extinguishment
devices, and a 2,500 recallable
event memory can be displayed
or printed. Fully warranted and
Factory Mutual (FM)* Approved.
CC-701, 702, 702+2
1, 2, or 4 zone capacity consoles;
motherboard construction; 1 or 2
sensors per zone (optional interface
for up to 8 pairs of sensors); micro-
processor based LCD-LED informa-
tion display. NEMA 4.
PART#
ITEM
581608
CC-701 Console
581609
CC-702 Console
581609B CC-702+2 Console
GreCon, Inc. 7747 SW Cirrus Drive Beaverton, Oregon 97008 Phone: 503/641-7731 Fax: 503/641-7508 www.grecon-us.com
3
Line Cards and
Input/Output Cards
For use with all modular BS-7
microprocessor consoles. Line
Cards and Input/Output Cards
can be used in any combination
to suit individual system require-
ments. FM Approved.
LC/72 Line Counter Card
Plug-in line card for the supervision
and control of 2 zones. Sparks, wire
rupture, or short circuit recognition.
Activation of 2nd Alarm Relay if
extinguishment or spark count
thresholds are exceeded.
PART#
ITEM
581709
LC/72 Line Card
LC/73 Line Counter Card
Plug-in line card for the supervision
and control of 2 zones. Sparks, wire
rupture, or short circuit recognition.
Activation of 2nd Alarm Relay if
extinguishment or spark count
thresholds are exceeded. Two toggle
switches for disabling zones without
accessing console menu.
PART#
ITEM
581708
LC/73 Line Card
New !
IO/71 Input/Output Card
Plug-in card for the wiring connection
of spark sensors, extinguishment
valve, water flow switch and dry relay
contacts for Alarm 1 or 2. Detects
and activates extinguishment in 1
area.
PART#
ITEM
581715
IO/71 Card
CC-704, 708, 712
4, 8, or 12 zone capacity consoles;
modular construction; 1 to 4 sensors
per zone (optional interface for up to
8 pairs of sensors); microprocessor
based LCD-LED information display.
NEMA 4.
PART#
ITEM
581610
CC-704 Console
581612
CC-708 Console
581620
CC-712 Console
CC-724
1-24 zones, modular construction; 1
to 4 sensors per zone (optional
interface for up to 8 pairs of sensors);
microprocessor based LCD-LED
information display. NEMA 4.
PART#
ITEM
581625
CC-724 Console
4
GreCon, Inc. 7747 SW Cirrus Drive Beaverton, Oregon 97008 Phone: 503/641-7731 Fax: 503/641-7508 www.grecon-us.com
Options and
Accessory Equipment
for BS-7 Systems
CI/16 Interface
For monitoring capability of up to 8
pairs of sensors per zone. (Not
available for CC-700 models.)
PART#
ITEM
581668
CI/16 Interface (BS-701
through BS-712)
581669
CI/16 Interface (BS-724)
IO/72 Input/Output Card
Accepts up to 3 additional valve
inputs from IO/71 cards to activate a
common extinguishment from an
alarm in up to 4 detection areas.
Single relay for Alarm 1, 2, or trouble.
Contacts to disable valve using an
access door limit switch.
PART#
ITEM
581714
IO/72 Card
IO/73 Input/Output Card
Terminal connection for additional
pair of sensors. Alarm from either
pair of sensors activates extinguish-
ment. Normally used in detection
before and after fan with extinguish-
ment prior to fan. Relays for Alarm 1,
2, or trouble; time delay status relay
for fan shutdown.
PART#
ITEM
5817145 IO/73 Card
New !
IO/74 Input/Output Card
Terminal connection for additional
pair of sensors. Alarm from either
pair of sensors activates extinguish-
ment. Normally used in detection
before and after fan with extinguish-
ment prior to fan. Relays for Alarm 1,
2, or trouble; immediate status relay
for fan shutdown.
PART#
ITEM
58171451
IO/74 Card
New !
Fire Protection Monitor
Software
System Software for interfacing up to
6 Control Consoles to a dedicated
PC.
PART#
ITEM
405051
RS-485 Interface Card for
Fire Monitor
NS
Fire Monitor Software
All BS-7 Systems are quoted
and sold as custom systems.
Be sure to check for the
correct Eprom Program
Version when ordering spare
parts. Please speak with
your Sales Representative or
a GreCon Technician if you
have any questions.
GreCon, Inc. 7747 SW Cirrus Drive Beaverton, Oregon 97008 Phone: 503/641-7731 Fax: 503/641-7508 www.grecon-us.com
5
Built-in Event Printer
Built-in Event Printer for models CC-
704 through CC-724.
PART#
ITEM
581770
IC/71 Interface Card
581870
BS7 Printer
571871
PR/71 Control Card
571873
Printer Cable
571872
Printer Cable (to LC/71)
562596
Printer Lid with Holder
Remote Printer
Stand-alone event printer for sepa-
rate connection to console via the
RS-485 serial port. Requires
separate 120 VAC power supply.
PART#
ITEM
404332
EP/7-485 Citizens Printer
Printer Accessories
PART#
ITEM
404323
2.38 wide Paper Roll
(for built-in printers)
404324
3 wide Paper Roll
(for remote printers)
404333
6 Connecting Cable
(for remote printers)
Tool Kit
For easy assembly of all mounting
adapters. Kit (581856) includes:
PART#
ITEM
558923
R1 - Hole Saw Arbor with
½ Shank
5589199 R2 - Hole Saw (32mm)
558922
R3 - Hole Saw (40mm)
558925
R4 - Quad-Tool
5589251 R5 - Wrench
Control Console Spare Parts
PART#
ITEM
581677 CC-701/702 Motherboard
581676 DZC/71 Double Zone Card
(+2 Motherboard)
5816765 NT-DZC/71 Power Supply
(CC-702+2)
581682 FP/71 Front Board (CC-704
through 712)
581645 MC/71 Multiplex Card
581640 MP/71 Master Proc. Card
581647 MP/71&RS-485 Serial Port
581633 PC/71 Power Control
581630 PL/71 Logic Power Supply
571871 PR/71 Printer Control Card
581631 PS/72 Power Supply
581675 PT/71 Transformer Line
Conditioner
551635 COU/71 Card
581650 SI/71 System Input Card
581665 SO/71 System Output Card
558276 Transformer 2 x 120 V
558141 Battery 12V x 6.5Ah
581696 Battery Cable (BS-7 with
spade)
581697 Battery Cable (BS-7 with
plug)
581574 KKS 1/8 Spark Switch
Terminal Box
558699 KKS 1/8 Mounting Plate
581578 KK-NI 1/8 Terminal Box
581579 KK-N 1/8 Terminal Box
558699 KK-NI 1/8 Mounting Plate
558693 KK-N 1/8 Mounting Plate
6
GreCon, Inc. 7747 SW Cirrus Drive Beaverton, Oregon 97008 Phone: 503/641-7731 Fax: 503/641-7508 www.grecon-us.com
Detection
GreCon Sensors contain photo
diode elements which detect
even the smallest sparks infra-
red radiation. Fiber optic cables
and sensors are available for
high temperature applications up
to 1830ºF. An internal test light
validates the electrical circuitry
and wiring. IP 65 (NEMA 4)
enclosures. Electronics are
shielded against UHF, VHF, or
other interference. Sensors are
easily installed or removed with
mounting adapters and quick
disconnect electrical plug* at
sensor.
*DLD 1/8 & TM 1/8 excluded
FM 1/8 Sensor
Low temperature/pressure application
sensor for the detection of infrared
radiation in the 400-1,200 nm
range.
PART#
ITEM
581540
FM 1/8 Sensor
FM 3/8 Sensor
High temperature/pressure applica-
tion sensor for the detection of
infrared radiation in the 400-1,200
nm range. Sensor is linked to the
duct via 3 fiber optic cables. Stain-
less steel cover protects cables
against mechanical damage.
PART#
ITEM
581550
FM 3/8 Sensor
DLD 1/8-A Daylight Sensor
Low temperature/pressure application
sensor for the detection of infrared
radiation in the 2,500-5,000 nm
range where ambient light is present.
PART#
ITEM
581591
DLD 1/8-A Sensor
KK 1/8 Terminal Box
Junction box for connecting FM
sensors to console. Provides for
sensors of different generations and
individual 12/24 VDC sensor testing.
PART#
ITEM
581580
KK 1/8 Terminal Box
TM 1/8 Rate-of-Rise Sensor &
Circuit Board
Heat sensor for early detection of
temperature rise caused by fire.
Standard activation temperatures:
140ºF, 190ºF, 225ºF. (Sensor Probe
listed separately.)
PART#
ITEM
581530
TM 1/8 Sensor
566831
TM 1/8 Circuit Board
GreCon, Inc. 7747 SW Cirrus Drive Beaverton, Oregon 97008 Phone: 503/641-7731 Fax: 503/641-7508 www.grecon-us.com
7
Fiber Optic Cables
Fiber Optic Cables for FM 3/8 high
temperature/pressure sensors.
PART#
ITEM
558956
1 Meter Cable
558957
2 Meter Cable
Rate-of-Rise Sensor Probes
Sensor Probes for TM 1/8 Rate-of-
Rise Sensors. (Other temperature
ratings are available.)
PART#
ITEM
404010
Sensor Probe - 140ºF
404012
Sensor Probe - 190ºF
404014
Sensor Probe - 225ºF
1/8 Sensor Mounting Adapter
Easy installation and removal adapters
for mounting FM 1/8 sensors to
application sidewalls. Assembly
(581565)* includes:
PART#
ITEM
5583750 Sensor Adapter Body
404150
Split Washer
404152
Solid Washer
404154
Lock Nut
404156
O-Ring
*(2) O-Rings included in assembly
Cable Mounting Adapter
Easy installation and removal adapt-
ers for mounting FM 3/8 sensor
cables. Assembly (581398) in-
cludes:
PART#
ITEM
558423
Sensor Adapter Body
404170
Wing Screw
404160
Split Washer
404162
Solid Washer
404164
Lock Nut
Fiber Optic Cables,
Sensor Probes,
and
Sensor Mounting
Hardware
NOTE: When replacing
obsolete FM 1/6, FM 1/7,
FM 3/6, or FM 3/7 sensors
with the newer FM 1/8 or
FM 3/8 models, KK 1/8
Terminal Boxes, SMA
bushings, and mounting
pl