LA SERIES
LA SERIES
3 Models · Single Output, Up to 700 Watts Redundant Hot Swap Power Supplies
FEATURES
Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Ø Greater than 12 W/in 75-80% typical efficiency 1U high - narrow profile Hot Pluggable Power Factor Corrected EN 61000-3-2 compliant Universal input UL, CSA, TÜV (IEC, EN), CB FCC, CISPR Class B EMI IEC, EN Immunity Standard features include: Isolated pilot bias Power Fail monitor DC Good signal Inhibit capability OVP on all models Overload and short circuit protection Reverse voltage protection Fan output Options and Accessories include: Redundancy via low drop Or-ing diode with single wire current share Nylon slides End fan cover 1U high racking system
3
DESCRIPTION
LA Series is part of Deltron's SlimLine group of 1 U high power supplies with dimensions of 1.58"H x 3.35"W x 11.15"L. This series of single output models is rated up to 700 watts and is hot-pluggable. Uniquely packaged and highly compact, LA Series modules fit a wide range of industrial, telecom and computer networking applications. Units can be paralleled for additional power or used in combination with other models to meet multiple output requirements. When used in Deltron's RA60A racking system, up to four LA Series units can be mounted in a 1U high rack space, to provide up to 2800 watts. Designed to meet applicable NEBS standards, units feature a proven topology coupled with excellent thermal management to achieve outstanding performance and safety. Power Fail and DC Good features provide logic signal for monitoring power supply status. All models are available with redundancy option for parallel or N+1 hot pluggable applications.
Ø
MODELS
Max Power 600 650 700 Output 12V @ 50A 24V @ 27A 48V @ 14.6A Model LA12-50-YY LA24-27-YY LA48-14.6-YY
LA SERIES RACK SYSTEM
The RA60A 1U high, 19"-wide racking system is available for paralleling or N+1 redundant systems. The 1.75"-high by 12.0"-deep rack accommodates up to four LA Series power supplies providing up to 2800 watts. Racks include a top cover for added strength and protection. Each power supply plugs into the backplane and is securely held in place by removable front panels. Individual output and signal connections are made via rear accessible studs and headers. A heavy duty barrier block is provided for input connections. Racks are designed to accept either EIA or Bellcore NEBS mounting and heavy-duty solid-bearing slides.
Other ratings available on special order. Replace the YY with the sum of the Option Codes below.
OPTIONS
Option Code 00 01 02 32 Function None Redundancy Nylon slides End Fan Cover
290 Wissahickon Avenue, North Wales, PA 19454 Phone: 800.523.2332 Fax: 215.699.2310 Email: sales@deltroninc.com Website: www.deltroninc.com
LA SERIES SPECIFICATIONS
INPUT 90-264 VAC, 47-63 Hz. Contact factory for 85 VAC operation. POWER FACTOR 0.95 typical. EMISSIONS EN 55022/CISPR 22, Class B Conducted. EN 61000-3-2, Harmonics. IMMUNITY EN 61000-4-2, Level 3 Electrostatic Discharge. EN 61000-4-4, Level 3 Electrical Fast Transients. EN 61000-4-5, Level 3 Surge. INPUT SURGE 230VAC - 50 amps max. 115VAC - 25 amps max. EFFICIENCY 75-80% typical. HOLDUP TIME 20 milliseconds from loss of AC power. OUTPUTS See model selection table. Outputs are trim adjustable ±5%. OUTPUT POLARITY Output is floating from chassis and can be referenced to ground as required. LINE REGULATION Less than 0.2% for full line change. LOAD REGULATION Less than 1% or 40mv for full load change. MINIMUM LOAD None required. RIPPLE & NOISE 1% or 50mV, pk.-pk. whichever is greater, 20 MHz bandwidth. OPERATING TEMPERATURE 0-70°C. Derate 2.5%/°C above 50°C. COOLING A minimum of 5 LFS* is required, directed through the unit for full rating. See optional fan cover. *Linear feet per second. TEMPERATURE COEFFICIENT 0.02%/°C typical. DYNAMIC RESPONSE Peak transient less than ±2% or ±100mv for a step load change from 75% to 50% or 100% max. Outputs recover within 300 microseconds. SAFETY Units designed to meet UL 1950/60 950, CSA 22.2 No. 950, EN 60 950. To be submitted. ISOLATION Conforms to safety agency standards. INPUT UNDERVOLTAGE Protects against damage for operation. undervoltage ENABLE Enable pin must be shorted to Common for proper operation. REMOTE SENSING Standard on output. SHOCK & VIBRATION Shock per MIL-STD 810-E Method 516.4, Procedure I. Vibration per MIL-STD 810-E Method 514.4, Category 1, Procedure I. MECHANICAL Chassis dimensions are 1.58" H x 3.35" W x 11.15" L. Length includes end fan cover. CONNECTIONS Connections via Positronic connector. WARRANTY Deltron's 2 year Standard Warranty applies.
SOFT START Units have soft start feature to protect critical components. OVERVOLTAGE PROTECTION Standard on all models. Latching action. REVERSE VOLTAGE PROTECTION All outputs are protected up to 100% load ratings. OVERLOAD & SHORT CIRCUIT Outputs are current limited with recovery when overload is removed. CURRENT SHARE Single wire current share. THERMAL SHUTDOWN Circuit cuts off supply in case of local over temperature. Units reset automatically when temperature returns to normal. POWER FAIL MONITOR Standard circuit provides TTL ACFAIL signal providing 4 millisecond warning before main output drops by 5% after an input failure. DC GOOD Standard circuit provides an energized open collector when any output is at least 90% of nominal value. INHIBIT TTL compatible system inhibit provided. FAN OUTPUT Nominal 12 VDC @ 8 watts maximum. ISOLATED PILOT BIAS 5 VDC @ 0.25 Amps. automatic
OPTIONS:
OR-ING DIODE (Code 01) Redundant operation with Schottky diode coupled with standard single wire current sharing for use as a hot pluggable N+1 redundant system. NYLON SLIDES (Code 02) Power supply chassis mounted slides provide ease of pluggability for use with Deltron model RA60A or equivalent racking system. END FAN COVER (Code 32) Optional cover with brushless DC ball bearing end fans provides the required airflow for full rating. For non-hot-pluggable models, the cover includes an IEC input connector. The end fan cover fits in 1.75" 1U rack height. It increases unit length by 1.30". RACKING SYSTEM The RA60A 1U high, 19" wide racking system is available for paralleling or N+1 redundant systems. The 1.75" H x 12.0" D rack accommodates up to four LA Series power supplies providing up to 2800 watts. Racks include a top cover for added strength and protection.
Specifications subject to change without notice.
.
3.35
6-32 MTG. HOLES 2 PLACES MAX. PENETRATION .062
3.66
1.68
0.48
1.56 2.20
6-32 MTG. HOLES 2 PLACES MAX. PENETRATION .062
6.00 5.45
0.58
SLIDE OPTION WIDTH
1.58
OPTIONAL NYLON SLIDES (2)
0.79 0.30 0.40 9.02 9.85
ALL DIMENSIONS IN INCHES
POWER AND CONTROL SIGNALS
1 2 3 4 5 6 7 8 9 10 11 12
13 14 15 16 19 22 25 23 26 27
1.30
ADD FOR END FAN COVER OPTION
29 28 30
17 20 18
1 2 3 4 5 6
V1+ V1+ V1+ V1+ V1V1-
7 8 9 10
12
V1V1SPARE SPARE SPARE SPARE
13 14 15 16
ENABLE SENSE 1 ( + ) SENSE 1 ( - ) INHIBIT MARGIN DC GOOD/GA1 22 23 24
COMMON (V1-) SHARE POWER FAIL HI TEMP/GA0 FAN FAIL/GA2 BIAS ( + )
25 26 27 28 29 30
SPARE SPARE/SCL SPARE/SDA GROUND NEUTRAL
21 24
POSITRONIC PCIM STYLE MATING CONNECTOR REQUIRED
LINE
308E