NMRA/ North Shore & Western Division HO Module Specifications Module Size:
NMRA/ North Shore & Western Division HO Module Specifications Module Size: Height: Clearances: Straight Module 30" x 48" (not including railings or width of backdrop) Floor to top of rail = 40" (Module height must be adjustable to +/- 1") Vertical from top of rail = 3" minimum Horizontal from center of track = 1" minimum This applies to, but is not limited to, all bridges, buildings, signals, and tunnels. Centerline of outer main track is measured 5" from front face of frame. Centerline of middle main track is measured 7" from front face of frame. Centerline of inner branch line track is measured 9" from front face of frame. Outer mainline is track #1 color code Red (public viewing side) Middle mainline is track #2 color code Yellow Inner branch line is track #3 color code Blue (operator's side) Both the main lines and the branch line must end 4-1/2" from each end of the module. Each module is connected by a standard 9" piece of commercial straight track, Code 100, nickel silver, Atlas Snap Track. Must be no less than 2" from mainlines or branch line. Mainline and branch line grade is 0% Mainline curves 32" minimum Industrial curves 24" minimum Main line must be at least Code 100, nickel silver, #6. Commercial Code 100, nickel silver diamonds are recommended. Must be insulated at crossover track to electrically isolate the two mainlines and the branch line. Mainlines and branch line track must be Code 100, nickel silver rail and ties must be .045" thick (Atlas). Hand laid track is acceptable. Roadbed can be any material that is 3/16" thick. Modeler's choice. 14" max. from top of rail. Color of sky - TBD
Mainlines:
Branch line:
Track designations:
Track ends:
Connecting track:
Sidings: Grade: Curves:
Turnouts: Diamonds: Crossovers:
Track:
Roadbed: Ballast: Backdrop & Paint:
NMRA/ North Shore & Western Division HO Module Specifications (Continued) Highway Crossings: Roadway material must be at least 1/32" below top of rail. Uncouplers: Scenery: Signals: None allowed in mainlines or branch line. Modeler's choice. All block signal and grade crossing flasher systems shall be independently powered and will not employ track detector circuits which need to be connected to the track current to operate. Independently operated opto-electric systems are suggested alternatives. General Electrical Specifications Connectors: All track power bus connectors shall be 2 pin "Jones" connectors. Male: Cinch p/n - P302CCT or equivalent Female: Cinch p/n S302CCT or equivalent #1pin (wide) of connectors to be wired to the rail closest to the module front (public viewing side). Auxiliary connectors, not used for track power buses, may be any suitable connector of the modeler's choice. Wire All interconnecting wire from module to module shall be 18 AWG stranded minimum. This includes track power bus and Accessory AC. All track off the mainlines must be electrically insulated from the mainlines, powered separately, and can be built free style. Tracks #1, #2, and #3 MUST NOT have any common connection. DO NOT use "COMMON RAIL" wiring. Gaps must be used on both rails on any crossover tracks. All interconnecting DCC data line from module to module shall be 6 conductor flat phone line. During normal module operation sessions Track #1 shall be powered and controlled with conventional DC power supply and throttle. During normal module operation sessions Track #2 shall be powered and controlled using DCC (Digital Command Control) by "System One" with the capability of switching to a conventional DC power supply and throttle if warranted. During normal module operation sessions Track #3 and all connecting yards and sidings shall be powered and controlled using DCC (Digital Command Control) by "System One".
Electrical isolation:
DCC network:
Track Power:
NS&W Modular Specifications
Module size & track spacing standard
48"
30"
5" FRONT 1 42" 1 42"
7"
9"
North Shore & Western Division, Midwest Region, NMRA
NS&W Modular Specifications
Module height standard
18" MAX.
40" TO TOP OF RAIL
+/-1" OF ADJUSTMENT REQUIRED
North Shore & Western Division, Midwest Region, NMRA
NS&W Modular Specifications
Module main bus line wiring requirements: Use 18 AWG stranded wire minimum
FEMALE CONNECTORS AT THIS END CINCH P/N S302CCT
WIRING NOTE: THE #1 PIN (WIDE) GOES TO THE RAIL CLOSEST TO THE FRONT FOR ALL TRACKS.
MALE CONNECTORS AT THIS END CINCH P/N P302CCT
BLUE YELLOW RED
12"
EXTEND WIRES
FRONT
12"
EXTEND WIRES
North Shore & Western Division, Midwest Region, NMRA