UNIVERSAL STARTING BLOCK
an=2 width=10 nowrap>
« back to results for ""
Below is a cache of http://srsmith.com/_posted_resources/Universal_installation.pdf. It's a snapshot of the page taken as our search engine crawled the Web.
The web site itself may have changed. You can check the current page or check for previous versions at the Internet Archive.
Yahoo! is not affiliated with the authors of this page or responsible for its content.
UNIVERSAL STARTING BLOCK
UNIVERSAL STARTING BLOCK
CORPORATE HEADQUARTERS
WESTERN SALES AND MANUFACTURING PLANT
P.O. Box 400 1017 SW Berg Parkway
Canby, Oregon 97013
(503) 266-2231 Fax (503) 266-4334
www.srsmith.com
06-709
DEC06
INSTALLATION INSTRUCTIONS
INTRODUCTION
The Universal Starting Blocks are designed for use on competitive or municipal pools. Proper installation,
use, and maintenance are essential for proper operation and to reduce the risk of accident or injury.
MODEL A** B C D E
USB 26-29.5
29.5
17.75 17.50 17.50 0.00
USB 26-29
29.0
17.25 17.25 17.25 0.50
USB 26-28.5
28.5
16.75 17.00 17.00 1.00
USB 26-28
28.0
16.25 16.75 16.75 1.50
USB 26-27.5
27.5
15.75 16.50 16.50 2.00
USB 26-27
27.0
15.25 16.25 16.25 2.50
USB 26-26.5
26.5
14.75 16.00 16.00 3.00
USB 26-26
26.0
14.25 15.75 15.75 3.50
USB 26-25.5
25.5
13.75 15.50 15.50 4.00
USB 26-25
25.0
13.25 15.25 15.25 4.50
USB 25-24.5
24.5
12.75 15.00 15.00 5.00
USB 25-24
24.0
12.50 14.75 14.75 5.50
USB 24-23.5
23.5
12.25 14.50 14.50 6.00
USB 24-23
23.0
12.00 14.25 14.25 6.50
USB 23-22.5
22.5
11.75 14.00 14.00 7.00
USB 23-22
22.0
11.50 13.75 13.75 7.50
USB 23-21.5
21.5
11.25 13.50 13.50 8.00
USB 23-21
21.0
11.00 13.25 13.25 8.50
USB 23-20.5
20.5
10.75 13.00 13.00 9.00
USB 23-20
20.0
10.50 12.75 12.75 9.50
USB 22-19.5
19.5
10.25 12.50 12.50 10.00
USB 22-19
19.0
10.00 12.25 12.25 10.50
USB 21-19
19.0 10.00 12.25 12.25 10.50
**IMPORTANT**
Check entire box and inside all packing materials for parts. Before beginning assembly, read the
instructions and identify parts using the figures and parts listed in this document. It is critical that all
parts be carefully inspected by the installer prior to installation to ensure that no damage occurred in
transit and that a damaged part is not used. Proper installation cannot be overstressed, as an improper
installation voids S.R. Smiths warranty and may affect the safety of the user.
FIGURE 1
**
nominal dimension
UNIVERSAL STARTING BLOCK PARTS LIST
ITEM NO
QTY
PART NO
DESCRIPTION
1 1
20-610SP-1PC
USB
FRAME POWDER COATED
2
1
8-622B
USB FOOTBOARD TOP
3 1 74-228-230
USB
STEP
4
2
8-600
WHITE VINYL HANDLE GRIP
5
8
05-616
1/2" NYLON WASHER
6
8
05-14-114
1/2" FLAT WASHER S/S
7
8
05-14-115
1/2" LOCK WASHER S/S
8
8
05-14-116
1/2"-13 HEX NUT S/S
9
1
EP-300
ESCUTCHEON, SQUARE 2.5" X 2.5"
10
1
27-107
SINGLE POST ANCHOR
FIGURE 2
UNIVERSAL STARTING BLOCK INSTALLATION
The Universal Starting Block anchor can be installed in an existing pool deck or set when pouring a new
concrete deck.
1. The wedge anchor should be installed in the
orientation shown in
FIGURE
3. As shown in
FIGURE 3
, the side of the anchor that
contains the wedge should be oriented such
that it is parallel to, and farthest away from,
the pool wall.
2. The setback for the anchor must be set
using the correct distance F from the pool
wall and with at least 6 from any control
joint or edge of concrete slab. The correct
setback distance depends on the model
ordered. When the starting block is installed,
the backstroke handles and leading edge of
the footboard shall be flush with the pool
wall. Refer to
FIGURES 4 & 5
.
3. Core drill at least a 6 ½-inch diameter hole
at the chosen location for the anchor if
installing the mounting anchor into an
existing deck. If the deck is new construction
the anchor shall be braced so it is not
moved from its proper position during
pouring of the deck.
4. Properly bond the anchor socket using the
attached bond lug and the appropriate
bonding wire per local codes. If electrical
bonding is required by the local
governmental regulations, it shall be done in
accordance with Article No. 680 of the
current National Electrical Code or the local
code whichever is greater.
5. With the anchor completely checked for
level and plumb in the selected position,
pour hydraulic cement or high strength epoxy
into the hole making sure there are no void
spaces if installing in an existing deck. If
installation is new construction, ensure anchor
is in its proper location and square to the pool
wall before pouring concrete.
POOL WALL
HIGH STRENGTH EPOXY/GROUT
ANCHOR SOCKET
6" MIN
EXISTING DECK
SET BACK
6. Let cement/grout cure for 24 hours (or
minimum manufactures recommendations)
before using starting platform anchor.
FIGURE 3
FIGURE 4
FIGURE 5
STARTING PLATFORM INSTALLATION AND REMOVAL:
When placing a starting platform into an anchor its important to follow these simple instructions.
1. Loosen bolt using a ¼ ALLEN wrench, turning wrench in a counter-clockwise direction as seen
from looking down. See
FIGURE 6
.
2. Make sure that the opening size directly adjacent to anchor bolt is between 2-9/16 (65mm) and
2-5/8 (66.7mm) wide. The opening in this direction should never exceed 2-5/8 (66.7mm) or the
anchor will disassemble!
3. Place escutcheon over starting platform frame tube orienting as shown. For the long reach model
make sure the escutcheon is orientated with the notch directly over the anchor bolt.
4. Place starting platform into anchor making sure that the platform frame rests completely on the
bottom of the anchor and the forward edge of the staring platform faces the pool edge.
5. Tighten ALLEN wrench in the clockwise direction until anchor wedge contacts the starting
platform frame and no forward or backward motion can be felt. When tightening anchor wedge,
never exceed 8 Ft-Lbs of torque. Anchor bolt should be snug but never over tightened.
6. To remove staring platform, lift escutcheon, insert ALLEN wrench into anchor bolt and turn
counter-clockwise two (2) full turns. For long reach models the anchor bolt is accessed through
the notch in the escutcheon. Lift and remove starting platform. DO NOT continue to loosen
anchor bolt or remove anchor bolt for any reason.
SAFETY & MAINTENANCE INSTRUCTIONS
Execute shallow racing dives only.
For use by trained competitive swimmers only.
Periodically inspect the Universal Starting Block to assure there are no
worn parts and that all hardware is properly tightened.
All stainless steel parts require periodic maintenance. Polishing with a
cotton cloth and a Windex-type product maintains the finish and restores
luster.
Use non-abrasive soap and water. Avoid harsh chemicals and
disinfectants. Always read the label instructions on any cleaner carefully
before applying it to a surface.
FIGURE 6