Marquis Spec Sheet Rev3 System Features
up to 10 fully programmable zones
- all zones programmable
- all zones supervised for low battery, tamper, device fault, open & close
- any zone may be converted to a keyswitch for arming/disarming
the system
12 programmable access codes
- 1 installer access code, 1 downloading computer access code
- 10 user codes including 1 master user code
- 1 of the user codes may be programmed as a one-time use code
open/close and partial close reporting by access code
quick-exit
- allows users to exit an armed system easily
home mode
- provides security of perimeter arming while premise is occupied
auto-interior bypass
- when turned onautomatically bypasses interior zones if no
exit is detected after arming
door chime
- when turned oncauses sounder to beep when a delay or
instant zone is activated (adjustable volume levels)
individual reporting of zone alarms, tamper alarms, low battery,
AC failure, device fault (supervisory) and restorals.
3 audible options : steady, pulsed, silent
- selectable Hi/Med/Low volume setting
8 programmable zone types :
- delay 1, delay 2, instant, interior, 24 hour, 24 hour medium buzzer,
key switch arm, fire, and panic
22 programmable system options including :
- quick exit, auto interior, door chime, one-time use code, pre-alert
volume setting, keypad alarm disable, and interior zone delay
5 programmable system times :
- entry delay (1 & 2), exit delay, burglary alarm cut-off time, and fire
alarm cut-off time
WLS900
continued
WLS900
Spread Spectrum
the
n e w b e n c h m a r k
i n
w i r e l e s s s e c u r i t y
10 Zones
10 User Codes
2 Keypads
2 Siren/Repeaters
2 Remote Sirens WLS902 Keypad
The Marquis system is fully programmable from the attractive, back-lit,
easy to use, English or French language WLS902 keypad :
900MHz Spread Spectrum wireless operation
full 2-way communications : keypad both transmits signals to
and receives signals from the controller
up to 2 keypads per system
large 32 character display of :
- zone identification
- system instructions
- system status
- alarm history
- trouble conditions
plain language operating instructions :
- menu for programming and user functions
- which key to press for specific functions
- steps for programming functions
3 dedicated One-Touch alarm keys : [F]ire, [A]uxiliary, [P]anic
backlit display
- display and keys backlit for easy viewing in low light conditions
- adjustable display contrast
keypad inactive state
- when inactive, keypad screen goes blank to conserve batteries
- simply press # to wake-up display
fully supervised by controller for :
- tamper - low
battery
- device fault
power requirement : 4 AA alkaline batteries (supplied)
operating temperature: 32° to 122°F (0° to 50°C)
dimensions : 7.68" W x 5.24" H x 1.06" D (19.5 x 13.3 x 2.7 cm)
WLS911 Siren/Repeater
The siren/repeater functions as the Marquis systems alarm siren and
audible annunciator for features such as door chime and walk test.
Further, the first siren/repeater in the system functions as a redundant RF
communications path providing "True Diversity" to ensure that signals
from the systems components reach the controller :
900 MHz Spread Spectrum wireless operation
up to 2 siren/repeaters per system
93 dB high output piezo siren - volume adjustable
door chime
alarm history
- system retains a record of sensors that went into alarm
during past armed periods
- alarm history can be viewed from keypad or remote DSC-DLS
programming software
upload / download capability
- program system from remote computer via DSC DLS software
- view status, trouble conditions, and alarm history
- flexible downloading options : answering machine override,
ring detect answering, downloading call-back, user initiated
downloading, and periodic (automatic) downloading
Fully Supervised
The following trouble conditions are displayed on all keypads by device
and type, and can also be transmitted to a monitoring station :
AC failure - controller, sounder 1, sounder 2
controller low battery
low battery, tamper, device fault (supervisory)
- sounder 1
- sounder 2
- keypad 1
- keypad 2
- individual zone detectors
telephone line trouble
failure to communicate
RF jam detect
loss of clock
Flexible Communications
industry standard communications formats :
- Silent Knight / Ademco Slow 10 BPS
- Sescoa, Franklin, DCI, Vertex 20 BPS
- Radionics 40 BPS with or without parity
- 1400 or 2300 Hz handshake as required by above formats
2 phone numbers - 1 account number
False Alarm Prevention Features
Fully programmable features to prevent false alarms and
unnecessary transmissions to the monitoring station include :
audible entry/exit delay
audible exit fault
auto-interior bypass
swinger shut down
interior zone with delay
opening after alarm code
burglary zone transmission delay
fire safety transmission delay
AC failure & zone low battery transmission delays
System Features continued
WLS901 System Controller
The controller contains the systems main electronic components : the
alarm control panel, digital communicator with built-in telephone jack
connections, and Spread Spectrum radio circuitry.
may be located virtually anywhere on premises where there is
an AC power source and telephone connection
fully supervised for :
- low battery
- AC failure
power requirement : 12 V AC adapter (supplied)
6 V 1.2 Ah sealed battery (supplied)
dimensions : 8.82" W x 5.24" H x 1.77" D (22.4 x 13.3 x 4.5 cm) transistor output switch to activate remote siren :
- activates a 30 watt self-contained battery backed-up siren
available from DSC
- activates on alarm and system test tones
- remote siren operates only when AC power is available unless
additional battery backup is provided
fully supervised by controller for :
- tamper - low
battery
- device fault
- AC failure
power requirement : 12 V AC adapter (supplied)
6 V 1.2 Ah sealed battery (supplied))
operating temperature: 32° to 122°F (0° to 50°C)
dimensions: 7.17" W x 4.41" H x 1.69" D (18.2 x 11.2 x 4.3 cm)
Wireless Detectors
WLS904 Passive Infrared Motion Detector
900MHz Spread Spectrum wireless operation
4 interchangeable lenses :
- wall-to-wall
- corridor
- curtain
- pet alley
detection area :
- wall-to-wall lens ......50' L x 60' W
(15.2 x 18.3 m)
- corridor lens............120' L x 10.5' W (36.6 x 3.2 m)
- curtain lens..............50' L x 4.4' W
(15.2 x 1.3 m)
- pet alley lens ..........50' L x 60' W
(15.2 x 18.3 m)
high traffic shutdown mode :
- prolongs battery life by automatically stopping reports to the
system controller if the detector is activated more than once in
a 3 minute period. Detector resumes normal transmissions to
the controller after a 3 minute period of no activity
fully supervised by controller for :
- tamper
- low battery
- device fault
standard corner or wall mount
optional adjustable wall and ceiling mount brackets
- adjustable up/down tilt and 90° rotation to obtain ideal position
for optimal coverage
power requirement : 4 AAA alkaline batteries (supplied)
operating temperature : 32° to 122°F (0° to 50°C)
dimensions : 2.44" W x 4.21" H x 1.93" D (6.2 x 10.7 x 4.9 cm)
Unlimited Flexibility !
Advanced motion
detector technology
fashioned after
DSCs Bravo3
!
Tampered
to ceiling
for superior
protection
!
WLS907 Universal Transmitter
may be used as a self contained magnetic door or window
contact or as a terminal connection for an external device
2 internal reed-switch contacts :
- accommodates different mounting requirements when used
as a self contained door or window contact
fully supervised by controller for :
- tamper
- low battery
- device fault
- open/close
power requirement : 3 AAA alkaline batteries (supplied)
operating temperature : 32° to 122°F (0° to 50°C)
dimensions : 4.5" W x 1.5" H x 1.13" D (11.4 x 3.8 x 2.9 cm)
WLS906 Photoelectric Smoke Alarm
UL/ULC approved
exclusive (patented) smoke chamber design provides :
- maximum smoke detection
- exceptional resistance to dust, insects and air turbulence
thereby lowering false alarms
90° smoke detection pattern
RED solid-state LED indicator light
loud 85 dB piezoelectric alarm horn
automatic self-test once every 40 seconds with visual and audible
trouble indication for low smoke sensitivity and low battery
manual user sensitivity test button with local indication
of test result
installers test mode allows test locally or by transmission
to Central Station
fully supervised by controller for :
- tamper - low
battery
- device fault
- low sensitivity
tampered to ceiling for protection against unauthorized removal
power requirement : 6 AA alkaline batteries (supplied)
operating temperature : 32° to 122°F (0° to 50°C)
dimensions : 5.5" Ø x 2" D (14 x 5.1 cm) Reliable Installation & Testing
True Diversity RF communications:
- each transmitter has
two paths to the controller
Path 1 : directly to the controller
Path 2 : to the sounder which relays the signal to the controller
- only one path has to be open to complete a transmission
module placement test mode
- allows installer to carry a keypad to the proposed locations f