Contactors SC-E series

ge or check for previous versions at the Internet Archive. Yahoo! is not affiliated with the authors of this page or responsible for its content.
Contactors SC-E series
34
Contactors SC-E series
Dimensions, mm
Non-reversing AC operated
SC-E02, E03, E04, E05
Panel drilling
34
13
60
(48 to)52
35
18.5(to 20.5)
14.5
43
80
49
20
(28)
8.561
81
91
(68)
10.5
*
1
Mounting hole
2-M4
(Rail height 15)
*
2
*
1
*
2
Main
terminal M4
Coil terminal
M3.5
2
1
Mass: 0.33kg
SC-E1, E2, E2S
106 (Rail height 15)
1
8
.
5
90
(28)
65.596
80
45(38 to 46)
45
75
16.5
57
54
10.5
9.5
5
(79)
2
2
1
Panel drilling
Mounting hole
2-M4
Main
terminal
Coil terminal
M3.5
*
1
*
1
*
2
*
2
Mass : 0.58kg
SC-E3, E4
90
13
72.5
20.5
77
1
9
.
5
1
12
(28)
10.5
67
(55 to)60
(54 to)60
121 (Rail height 15)
111
2.5
(91)
2
1
Panel drilling
Mounting hole
2-M4
Main
terminal
Coil terminal
M3.5
*
2
*
2
*
1
*
1
Mass: 1.1kg
SC-E5
75
77
32.7
70
132
88
32
155
13.5
129
(111)
4
Auxiliary
terminal
M3.5
Panel drilling
Mounting hole
2-M4
Main
terminal
Coil terminal
M3.5
*
1
Mass: 2.0kg
*
1
Side mounting aux. contact block
*
2
Front mounting aux. contact block
Wiring diagrams
*
1
*
1
6/T3
4/T2
2/T1
53
61 1/L1 3/L2 5/L3 83
71
A1
A2
72
84
62
54
*
1
In case of aux. contact 2NO+2NC
*
1
In case of aux. contact 2NO+2NC
*
1
*
1
6/T3
4/T2
2/T1
53
61 1/L1 3/L2 5/L3 83
71
A1
A2
72
84
62
54
*
1

In case of aux. contact 2NO+2NC
*
1
*
1
6/T3
4/T2
2/T1
53
61 1/L1 3/L2 5/L3 83
71
A1
A2
72
84
62
54
*
1
In case of aux. contact 4NO+4NC
6/T3
4/T2
2/T1
*
1
53
61 13 21 1/L1 3/L2 5/L3 43 31 83 71 A1 A2
72
84
32
44
22
14
62
54
*
1
Use the two mounting holes on a diagonal line
or to mount contactor
: 35 60 : 35 (48 to) 52
Use the two mounting holes on a diagonal line
or to mount contactor
: 45 75 : 45 (38 to 46) 80
Use the two mounting holes on a diagonal line
or to mount contactor
: (55 to) 60 90 : (54 to) 60 90
Dimensions 35
Dimensions, mm
Non-reversing AC operated
SC-E6
(80 to)90
1
10
32
169
143
13.5
100
38.8
138
77
(123)
4
Auxiliary
terminal
M3.5
Panel drilling
Mounting hole
2-M5
Main
terminal
Coil terminal
M3.5
*
1
Mass: 2.6kg
SC-E7


35
140
38.8
76.8
146
14.5
175
(138)
115
(80 to)90
1
10
Auxiliary
terminal
M3.5
Panel drilling
Mounting hole
2-M5
Main
terminal
Coil terminal
M3.5
*
1
Mass: 2.9kg
Non-reversing DC operated
SC-E02/G, E03/G, E04/G, E05/G
Panel drilling
Mounting hole
2-M4
Main
terminal
M4
Coil terminal
M3.5
*
1
*
1
*
2
*
2
(28)
8.5
88108
118 (Rail height 15)
13
43
80
49
20
(68)
10.5
34
60
(48 to)52
35
18.5(to 20.5)
14.5
2
1
Mass: 0.59kg
SC-E1/G, E2/G, E2S/G
130 (Rail height 15)
1
8
.
5
90
(28)
16.5
57
10.5
121.5
91
2
54
(79)
5
9.5
75
45
45(38 to 46)
80
1
2
Panel drilling
Mounting hole
2-M4
Main
terminal
Coil terminal
M3.5
*
2
*
2
*
1
*
1
Mass: 0.79kg
*
1
Side mounting aux. contact block
*
2
Front mounting aux. contact block
Wiring diagrams
*
1
In case of aux. contact 4NO+4NC
6/T3
4/T2
2/T1
*
1
53
61 13 21 1/L1 3/L2 5/L3 43 31 83 71 A1 A2
72
84
32
44
22
14
62
54
*
1
*
1
In case of aux. contact 4NO+4NC
6/T3
4/T2
2/T1
*
1
53
61 13 21 1/L1 3/L2 5/L3 43 31 83 71 A1 A2
72
84
32
44
22
14
62
54
*
1
*
1
*
1
6/T3
4/T2
2/T1
53
61 1/L1 3/L2 5/L3 83
71
A1
A2
72
84
62
54
*
1
In case of aux. contact 2NO+2NC
*
1
In case of aux. contact 2NO+2NC
*
1
*
1
6/T3
4/T2
2/T1
53
61 1/L1 3/L2 5/L3 83
71
A1
A2
72
84
62
54
Use the two mounting holes on a diagonal line
or to mount contactor
: 35 60 : 35 (48 to) 52
Use the two mounting holes on a diagonal line
or to mount contactor
: 45 75 : 45 (38 to 46) 80
Contactors SC-E series
Dimensions 36
Contactors SC-E series
Dimensions, mm
Non-reversing DC operated
SC-E3/G, E4/G
20.5
77
1
9
.
5
1
12
(28)
91.5130
140 (Rail height 15)
10.5
2.5
67
(91)
(54 to)60
(55 to)60
13
90
1
2
Panel drilling
Mounting hole
2-M4

Coil terminal
M3.5
*
2
*
2
*
1
*
1
Mass: 1.4kg
Main
terminal
Auxiliary contact blocks Front mounting
SZ-A40/T, A31/T, A22/T, A20/T, A11/T, A02/T for SC-E02 to E4
5
25
43
10
11
7.7
10
24
7.7
49
M3.5
M3.5
28 49
28
Approx
3
A
C
Approx
3
B
Contactor with aux. contact block
A
B
SZ-A40/T, A31/T, A22/T Mass: 36g
SZ-A20/T, A11/T, A02/T Mass: 20g
Auxiliary contact blocks Side mounting
SZ-AS1/T, for SC-E02 to E4
28
43
59.5
7.7 12 7.5
45
M3.5
A
B
C
12
12
D
Contactor with aux. contact block
Mass: 28g
SZ-AS2/T, for SC-E5 to E7
C
12
12
A
B
64.5
12
7.7
M3.5
28
47
7
47.5
Contactor
with aux. contact block
D
Mass: 40g
Type
SC-E02, E03, E04, E05
SC-E1, E2, E2S
SC-E3, E4
A
43
54
67
B
80
90
112
C
109
124
139
Type
SC-E02, E03, E04, E05
SC-E1, E2, E2S
SC-E3, E4
A
67
78
91
B
80
90
112
C
81
96
111
D
43
54
67
Type
SC-E5
SC-E6
SC-E7
A
112
124
139
B
155
169
175
C
132
138
140
D
88
100
115
Wiring diagrams
53 63 73 83
54 64 74 84
53 61 73 83
54 62 74 84
53 61 71 83
54 62 72 84
4NO
3NO+1NC
2NO+2NC
53 63
54 64
53 61
54
62
51 61
52 62
2NO
1NO+1NC
2NC
1NO+1NC
1NO+1NC
53 61
54
62
71 83
72 84
Mounted on right side
Mounted on left side
53 61
54
62
71 83
72 84
Mounted on right side
Mounted on left side
Use the two mounting holes on a diagonal line
or to mount contactor
: (55 to) 60 90 : (54 to) 60 90
*
1

In case of aux. contact 2NO+2NC
*
1
*
1
6/T3
4/T2
2/T1
53
61 1/L1 3/L2 5/L3 83
71
A1
A2
72
84
62
54
*
1
Side mounting aux. contact block
*
2
Front mounting aux. contact block
Dimensions 37
Contactors SC-E series
Dimensions, mm
Main circuit surge suppression units
Type
SC-E02+SZ-ZM1E
SC-E03
SC-E04
SC-E05
SC-E1+SZ-ZM3E
SC-E2
SC-E2S
SC-E3+SZ-ZM3E
SC-E4
A
43
54
67
B
80
90
112
C
121
136
151
34
4.5
43
45
27
34
4.5
43
45
27
A
B
C
Min.5
45
34
SZ-ZM3E
SZ-ZM1E
Contactor with surge suppression unit
Mass: 60g
60
22
37
39
60
22
37
39
C
A
B
22
39
D
Type
SC-E02+SZ-ZM2E
SC-E03
SC-E04
SC-E05
SC-E1
SC-E2+SZ-ZM2E
SC-E2S
SC-E3+SZ-ZM2E
SC-E4
A
65
76
89
B
80
90
112
C
81
96
111
D
43.5
49
55.5
SZ-ZM4E
SZ-ZM2E
Contactor with surge suppression unit
Mass: 60g
Connection diagram
5
31
6
4
2
Contactor
Thermal overload relay
M
Motor
W
V
U
Main circuit surge suppression unit
Coil surge suppression units
SZ-Z1, Z2, Z3, Z4, Z5
27 10
14
15
26
Mass: 14g
SC-E02 to E05 + SZ-Z1 to Z3
(Built-in varistor)
SC-E02 to E05 + SZ-Z4, Z5
(Built-in CR)
C
R
SZ-Z6, Z7, Z8, Z9
27 10
14
LED
LED
35
15
Mass: 16g
SC-E02 to E05 + SZ-Z6, Z7
(Built-in varistor with operating indicator)
R
SC-E02 to E05 + SZ-Z8, Z9
(Built-in CR with operating indicator)
R2
R1
C
SZ-Z31, Z32, Z33, Z34, Z35, Z36, Z37
30
37
12.5
26
13.5
Mass: 15g
SC-E1 to E4 + SZ-Z31 to Z33
(Built-in varistor)
SC-E1 to E4 + SZ-Z34, Z35
(Built-in
CR)
SC-E1/G to E4/G + SZ-Z36, Z37
(Built-in CR)
C
R
Dimensions