NX Latch Retention Compliance
Test 555
Larry Crofoot, Senior Engineer
Bob Bruner, Senior Technician
1/11/07

Purpose
To determine the compliance of Meritecs NX latch with InfiniBand retention
specifications per Table 30 of the InfiniBandTM Architecture Specification, Volume 2,
Release 1.2.1, October 2006.

Results
All parts passed the requirement of a minimum retention force of 75 newtons or 16.86
pounds. The straight connectors required between 45 and 48 pounds to disconnect and
the angled connectors required between 30 and 40 pounds to disconnect.

Samples Tested
Two (2) 4X angled and three (3) 4X straight latch Meritec connectors

Test Equipment
Instron Model 1000 Test Stand

Test Setup
The Instron was calibrated for a 100 lb. pull and the assemblies were held with two
screw-action grippers. The cable assembly was plugged into a 4X Molex receptacle
that was attached to Meritecs Test Board # 681185-01. The test board and receptacle
were then clamped securely into the Instron test instrument, with the bottom screw-
action gripper clamped to the receptacle and board and the top screw-action gripper
clamped to the backshell of the cable assembly under test. See figures 1 thru 4.


- 2 -

Figure 1) Instron Test Stand


Figure 2) Detail of clamping arrangement.
The straight male connector and latch under test are located in the top clamp and the receptacle
and test board are located in the bottom clamp

Property of Meritec -
©
Meritec 2006
MERITEC
1359 WEST JACKSON STREET POST OFFICE BOX 8003 PAINESVILLE, OHIO 44077 888-MERITEC (888-637-4832) / (440)-354-3148 FAX: (440) 354-0509 WWW.MERITEC.COM INFO@MERITEC.COM


- 3 -

Figure 3) Detail of clamping arrangement.
The angled male connector and latch under test are located in the top clamp and the receptacle
and test board are located in the bottom clamp


Figure 4) Detail of clamping arrangement.
The angled male connector and latch under test are located in the top clamp and the
receptacle and test board are located in the bottom clamp.

Property of Meritec -
©
Meritec 2006
MERITEC