POWER PRESENTATION PRODUCTS The In

may have changed. You can check the current page or check for previous versions at the Internet Archive. Yahoo! is not affiliated with the authors of this page or responsible for its content.
POWER PRESENTATION PRODUCTS The In DA-LITE SCREEN COMPANY, INC.
3100 North Detroit Street
Post Office Box 137
Warsaw, Indiana 46581-0137
Phone: 574-267-8101
800-622-3737
Fax: 574-267-7804
Toll Free Fax: 877-325-4832
www.da-lite.com
e-mail: info@da-lite.com
POWER
PRESENTATION PRODUCTS
The
In
Instruction Book for
ADVANTAGE
®
ELECTROL
® If your screen was shipped with the motor and roller already installed, proceed to step 6.
1. Remove access door. First, remove the 2 screws from the ends. Be sure to support the door during this
step to avoid injury. Then lift the door slightly and pull away from the edge of the case.
2. Carefully unpack screen and roller assembly. Leave packing paper on roller.
3. To install screen and roller assembly, insert the motor end into the motor mount bracket as shown in Fig. 1.
4. Loosen (but do not remove) two 1/4-20 nuts securing pin end bracket (stage left) to the case housing. Slide the
bracket towards the end of the case. Insert the motor end square shaft into the motor end bracket and secure with
the clip. Insert the tip of the roller pin into the bracket and position. Tighten the 1/4-20 nuts securely.
5. Complete electrical hook-up by snapping motor wire connector into case connector.
6. Carefully remove paper and tape from roller assembly. DO NOT use a knife or sharp object to cut tape; you will
damage the screen. Pull orange string.
7. Test installation by running screen up and down a few times. Be prepared to stop screen.
8. Re-install access door. Procedure is reverse of removal (step 1).
CAUTION! Excessive continuous operation may cause the motor to overheat. If this happens, the motor will shut off until it
cools to a normal operating temperature.
1. Remove 2 screws to open junction box.
2. Hang case and attach to support structure with bolts. See suggested methods of installation on page 5.
3. Tighten bolts until trim flange is flush with ceiling.
NOTE: For proper operation, screen assembly must be level after installation.
4. Install electrical connections that applies to your unit. Make sure to review the wiring diagram for proper hook up.
5. Replace junction box cover and secure with 2 screws.
PRE-INSTALLATION
1
1. Carefully unpack case from shipping carton. DO NOT unpack fabric and roller assembly yet.
2. Make sure to recheck measurement of case for proper installation clearance.
3. Remove any protective foam or tape from case.
SCREEN AND ROLLER ASSEMBLY INSTALLATION !
CASE INSTALLATION
IMPORTANT SAFETY INSTRUCTIONS
When using your video equipment, basic safety precautions should always be followed, including the
following:
1. Read and understand all instructions before using.
2. Position the cord so that it will not be tripped over, pulled, or contact hot surfaces.
3. If an extension cord is necessary, a cord with a current rating at least equal to that of the appliance
should be used. Cords rated for less amperage than the appliance may overheat.
4. To reduce the risk of electric shock, do not disassemble this appliance. Contact an authorized
service dealer when repair work is required. Incorrect reassembly can cause electric shock when
the appliance is used subsequently.
5. The use of an accessory attachment not recommended by the manufacturer may cause a risk of
fire, electric shock, or injury to persons.
SAVE THESE INSTRUCTIONS LOW-VOLTAGE WALL SWITCH
OPTIONAL IR AND RF
REMOTE CONTROL
MOTOR
WHITE (COMMON)
BLACK (HOT)
GREEN
GROUND TO CASE
120VAC 60HZ
120V WIRING DIAGRAM
WITH
OPTIONAL BUILT-IN
LOW VOLTAGE CONTROL
SPLITTER
RJ22
UP
STOP
DOWN
GROUNDMUST BE
CONNECTED TO
BUILDING GROUND
RJ22
GREEN
FRONT
BACK
UP DN
GND +5V
3-POSITION
SWITCH
RJ22
ILT RJ22 PIN-OUTS
(TAB IS FACING UP)
IR or UP
BLACK
GND COMMON
RED
+5V
GREEN
DN or DATA
WHITE
UP
+5V
COM
DN
DRY CONTACTS
2
ADVANTAGE
®
ELECTROL
®
INSTALLATION FOR 120V SCREENS
UP
OFF
DOWN
THIS SWITCH CAN NOT
BE USED WITH LVC.
120V WIRING DIAGRAM
FOR STANDARD
WALL SWITCH
SPDT SWITCH WITH
CENTER OFF
AC (COMMON)
AC HOT 120VAC 60HZ 1 AMP
BLACK/YELLOW
BLACK
RED
WHITE
RED (UP)
BLACK (DOWN)
JUNCTION BOX
LOCATED IN LEFT
ENDCAP
WHITE
RED
BLACK
GREEN
MOTOR
NOTE: A SINGLE SWITCH CANNOT BE USED TO OPERATE MORE THAN
ONE SCREEN. CONTACT THE FACTORY FOR FURTHER
INFORMATION.
FIGURE 3
FIGURE 5
120V WIRING DIAGRAM WITH
OPTIONAL BUILT-IN VIDEO
PROJECTOR INTERFACE
FIGURE 4
GREEN (GROUND)
BLACK (DOWN)
WHITE (COMMON)
RED (UP)
110VOLT AC/60HZ
POWER SOURCE
BLACK (HOT)
WHITE (COMMON)
GREEN (GROUND)
BLACK (DOWN)
BLACK/YELLOW (HOT)
RED (UP)
BLACK (GRD)(-)
RED (SIG)(+)
5/12 VOLT SCREEN
TRIGGER ON PROJECTOR
IMPORTANT NOTE: The wall switch is REQUIRED to make any limit
switch adjustments, EVEN if a third party control
system is used. Therefore, it is advised to wire
the switch or provide a 4-conductor connection
that is accessible.
CAUTION: THE PROJECTOR MUST BE TURNED OFF BEFORE CONNECTING THE TRIGGER WIRES TO THE PROJECTOR. FAILURE
TO DO SO MAY DAMAGE THE CONTROLLER.
1. Use 2-conductor 20-24 gauge wire to extend the low voltage connection from the projectors 5 or 12-volt screen
trigger output to the length required to reach the VPI. When extending the low voltage connection from the
projectors screen trigger output, be sure to maintain the proper polarity. The red wire from the VPI is the signal
and the black wire from the VPI is the ground.
2. Connect the wires from the VPI that are labeled Low Voltage Connection to the end of the extended screen
trigger wires above.
3. The wall switch must be placed in the up position for the screen to be triggered by the projector.
4. If a wall switch is not being used, please do the following. For 120V units, the black/yellow lead and the red lead for
the wall switch must be connected to each other and the black lead must be capped. For 240V units, the
black/yellow lead and the black lead for the wall switch must be connected to each other and the brown lead must
be capped. ! LOW-VOLTAGE WALL SWITCH
OPTIONAL IR AND RF
REMOTE CONTROL
MOTOR
BLUE (COMMON)
BROWN (HOT)
GREEN
GROUND TO CASE
240VAC 50HZ
240V WIRING DIAGRAM
WITH
OPTIONAL BUILT-IN
LOW VOLTAGE CONTROL
RJ22
UP
STOP
DOWN
GROUNDMUST BE
CONNECTED TO
BUILDING GROUND
RJ22
GREEN
FRONT
BACK
UP DN
GND +5V
3-POSITION
SWITCH
RJ22
ILT RJ22 PIN-OUTS
(TAB IS FACING UP)
IR or UP
BLACK
GND COMMON
RED
+5V
GREEN
DN or DATA
WHITE
DRY CONTACTS
SPLITTER
UP
+5V
COM
DN
3
240V WIRING DIAGRAM
FOR STANDARD
WALL SWITCH
UP
OFF
DOWN
THIS SWITCH CAN NOT
BE USED WITH LVC.
REAR OR DPDT SWITCH
WITH CENTER OFF
BROWN AND YELLOW AC HOT
220/240 VAC 50HZ 2 AMP.
BLUE AC COMMON
BROWN
BLUE JUMPER
WIRE
BLUE
BLACK (UP)
BROWN (DOWN)
JUNCTION BOX
LOCATED IN LEFT
ENDCAP
BLUE
BLACK
BROWN
GREEN
MOTOR
NOTE: A SINGLE SWITCH CANNOT BE USED TO OPERATE MORE THAN
ONE SCREEN. CONTACT THE FACTORY FOR FURTHER
INFORMATION.
BLACK
FIGURE 6
FIGURE 8
ADVANTAGE
®
ELECTROL
®
INSTALLATION FOR 220/240V SCREENS
240V WIRING DIAGRAM WITH
OPTIONAL BUILT-IN VIDEO
PROJECTOR INTERFACE
FIGURE 7
GREEN/
YELLOW
(GROUND)
BROWN
BLUE
BLACK
240VOLT AC/
50HZ POWER
SOURCE
BROWN (HOT)
BLUE
YELLOW/GREEN (GROUND)
POWER SOURCE BLUE
TO WALL SWITCH
BLACK/YELLOW
BLACK (UP)
BLACK (GRD)(-)
RED (SIG)(+)
5/12 VOLT SCREEN
TRIGGER ON PROJECTOR
MOTOR BLUE TO
WALL SWITCH
BACK OF SWITCH
BROWN
BLACK
BLUE TO MOTOR
BLUE TO
POWER SOURCE
BLUE JUMPER
BLACK/YELLOW (HOT)
IMPORTANT NOTE: The wall switch is REQUIRED to make any limit
switch adjustments, EVEN if a third party control
system is used. Therefore, it is advised to wire
the switch or provide a 4-conductor connection
that is accessible.
CAUTION: THE PROJECTOR MUST BE TURNED OFF BEFORE CONNECTING THE TRIGGER WIRES TO THE PROJECTOR. FAILURE
TO DO SO MAY DAMAGE THE CONTROLLER.
1. Use 2-conductor 20-24 gauge wire to extend the low voltage connection from the projectors 5 or 12-volt screen
trigger output to the length required to reach the VPI. When extending the low voltage connection from the
projectors screen trigger output, be sure to maintain the proper polarity. The red wire from the VPI is the signal
and the black wire from the VPI is the ground.
2. Connect the wires from the VPI that are labeled Low Voltage Connection to the end of the extended screen
trigger wires above.
3. The wall switch must be placed in the up position for the screen to be triggered by the projector.
4. If a wall switch is not being used, please do the following. For 120V units, the black/yellow lead and the red lead for
the wall switch must be connected to each other and the black lead must be capped. For 240V units, the
black/yellow lead and the black lead for the wall switch must be connected to each other and the brown lead must
be capped. ! Surface travel is stopped automatically in the fully opened and closed positions by limit switches that are properly
adjusted at Da-Lite. Should it be necessary to adjust for more or less drop of picture, proceed in the following manner:
Remove two screws to remove access door.
NOTE: Use a screw driver or 5/32" Allen wrench to make adjustments.
MORE SCREEN DROP
1. Place operating switch in down position.
2. When the screen stops, turn th