ELECTRONIC THERMOSTATS

br>costs.
!
N320 Model: Digital electronic thermometer that indicates
measured temperature values. Offset adjustment.
!
N321/N322/N323 Models: Thermostat with one, two or three
relay outputs. They can be configured through keypad for
heating or cooling control. They all feature a relay output for
control, N322 has also an alarm output and N323 has two alarm
outputs. The alarm output can be configured as minimum,
maximum or differential alarm.
Example: Multi-stage HVAC systems.
!
N321R Model: Automatically defrosts by interrupting the
compressor activity with programmable time interval and
manual defrost key. Holds indication while the defrosting cycle
is performing. Application example: Chambers and frozen food
displays.
!
N322T Model: Thermostat with two relay outputs. It features a
relay output for control and a relay with timed triggering for use
in enforced defrosting, agitation and other applications that
require periodic triggering. It is employed in HVAC systems.
Example: Milk coolers and heating pumps.
!
N322RHT Model: Digital controller for relative humidity and
temperature. It features two relay outputs for control that can
be separately configured as control or alarm.
Example: Fruit storage and air conditioning.
!
N323R Model: Thermostat that controls the end of defrosting
by temperature. It features three output relays: compressor,
defrosting and fan. Operates with two sensors (NTC), one for
room temperature and other to be attached to the evaporator
for control of defrost end. Employed in cooling and defrosting.
Example: Frozen chambers and displays.
!
LED indicators 3 ½ digits.
!
Sensor offset adjustment.
!
Adjustable hysteresis.
!
Minimum and maximum range for configurable setpoints.
!
Configuration is maintained even with energy failures.
!
Configurable password for configuration lock.
!
Long life silicone keys.
!
CE and UL Certified. (USA and Canada).
OPTIONAL:
!
RS485 interface with Modbus RTU protocol.
!
Power supply: 12 to 24 Vcc.
HOW TO SPECIFY
!
Range of Measurement Temperature:
- NTC: -50 to 120 °C (-58 to 248 °F) ;
- Pt100: -50 to 300 °C (-58 to 572 °F);
- Pt1000: -200 to 530 °C (-328 to 986 °F);
- Keypad-selectable thermocouples
(Except N321R and N323R):
- J Thermocouple 0 to 600 °C (32 to 1112 °F);
- K Thermocouple -50 to 1000 °C (-58 to 1832 °F);
- T Thermocouple -50 to 400 °C (-58 to 752 °F);
!
Accuracy:
- NTC: 0.6 °C (1,08 °F);
- Pt100 and Pt1000: 0.7 °C (1,26 °F);
- Thermocouple: 3 °C (5,4 °F).
!
RHT Accuracy 3% at 25 °C, 20 to 80% RH.
!
Output 1: SPDT relay, 1HP(16A resistive) /250 Vac.
!
Output 2: SPST relay, 3 A (5A resistive) /250 Vac.
!
Output 3: SPST relay, 3 A (5A resistive) /250 Vac.
!
Resolution: 0,1°C or 0,1 °F ranging from -19,9 to 199,9 °C/°F.
!
Front-panel with IP56 protecton.
!
Sampling: 1.5 times per second.
!
Power supply: 100 to 240 Vac /dc ±10%.
!
Frequency: 50~60 Hz.
!
Consumption: 5 VA.
!
Dimensions: 75 x 33 x 2.95 mm.
!
Panel cutout: 70 x 29 mm.
!
Weight: 120 g.
!
Operating temperature: 0 to 40 °C (32 to 104 °F) .
!
Storage temperature: -20 to 60 °C (-4 to 140 °F).
NTC or
Pt100 or
Pt1000 or
J/K/T (Thermocouples)
Blank or
485 (RS485, RTU Modbus Protocol)
Blank (100-240 Vac/cc) or
24V (24 Vac/cc)
A: Sensor:
B: Communication:
C: Power supply:
Model: N323 - A - B - C, where:
info@novus.com.br
NOVUS AUTOMATION
www.novusautomation.com
TEL. 55 51 3323-3600 FAX: 55 51 3323-3645
D2
T
H
E
R
M
O
S
T
A
T
S
T
H
E
R
M
O
S
T
A
T
S
D
FEATURES N322 RHT MEASUREMENT ACCURACY AND SENSOR OPERATING LIMITS
Normal
Operation
Conditions
Extreme
Operation
Conditions
100
[%RH]
80
60
40
20
-40
-20
0
20
40
60
80
100
[ºC]
120
0
Sensor Operation Conditions
Relative Humidity Accuracy @ 25 ºC
80 90 100
%RH
5
4
3
2
1
0
0 10 20 30 40 50 60 70
%RH
Temperature Accuracy
2 ºC
1ºC
0 ºC
-40ºC
-40ºF
3 ºC
0ºC
32ºF
40ºC
104ºF
80ºC
176ºF
3.6 ºF
1.8ºF
0 ºF
5.4 ºF
N321/N321R
N320
ELECTRICAL CONNECTIONS
N322RHT
N322/N322T
N323R
N323
OUTPUT1
OUTPUT2
NC
NO
C
SENSOR INPUT
D1
C
RS485
D0
POWER
ac/dc
1
2
3
4
5
6
8
9
10
11
12
13
MAINS
OUTPUTS
* SERIAL
COMMUNICATION
SENSORS
PROBE
10
11
12
13
OUTPUT1
NC
NO
C
SENSOR INPUT
D1
C
RS485
D0
POWER
ac/dc
1
2
3
4
5
6
8
9
10
11
12
13
MAINS
OUTPUTS
* SERIAL
COMMUNICATION
INPUT
SENSOR
OUTPUT1
OUTPUT2
NC
NO
C
SENSOR INPUT
D1
C
RS485
D0
POWER
ac/dc
1
2
3
4
5
6
8
9
10
11
12
13
MAINS
OUTPUTS
* SERIAL
COMMUNICATION
INPUT
SENSOR
OUTPUT1
OUTPUT2
NC
NO
C
SENSOR INPUT
D1
C
RS485
D0
POWER
ac/dc
1
2
3
4
5
6
8
9
10
11
12
13
MAINS
OUTPUTS
* SERIAL
COMMUNICATION
INPUT
SENSOR
OUTPUT3
7
OUTPUT1
OUTPUT2
OUTPUT3
NC
NO
C
S
E
N
S
O
R

2
D1
C
RS485
D0
POWER
ac/dc
1
2
3
4
5
6
7
8
9
10
11
12
13
ROOM
SENSOR
EVAPORATOR SENSOR
MAINS
*

C
O
O
L
I
N
G
S
E
N
S
O
R

1
V
E
N
T
I
L
A
T
I
O
N
*

D
E
F
R
O
S
T
I
N
G
C
O
M
M
O
N

T
O

O
U
T
P
U
T
S
SENSOR INPUT
POWER
ac/dc
1
2
11
12
13
MAINS
INPUT
SENSOR
info@novus.com.br
NOVUS AUTOMATION
www.novusautomation.com
TEL. 55 51 3323-3600 FAX: 55 51 3323-3645
D3
T
H
E
R
M
O
S
T
A
T
S
T
H
E
R
M
O
S
T
A
T
S
D