PAQ100 Series

R3 PAQ100S48-5
ITEMS
Nominal Output Voltage
V
1.2
1.8
2.5
3.3
5
Max Output Current
A
25
25
25
25
20
Max Output Power
W
30
45
62.5
82.5
100
Efficiency (Typ.)
(*1)
%
80
84
86
89
90
Input Voltage Range
-
36 - 76VDC
Input Current (Typ.)
(*1)
A
0.8
1.14
1.55
1.98
2.37
Output Voltage Accuracy (*1)
%
±1
Output Voltage Range
(*4)
-
-20%, +10%
±15%
Max Ripple & Noise
(*4)
mV
100
100
100
100
100
Max Line Regulation
(*2)
mV
10
10
10
10
10
Max Load Regulation
(*3)
mV
10
10
10
10
10
Over Current Protection
-
105% - 140% (Self-Recovering /V option)
Over Voltage Protection
-
120%
- 140% (Self-Recovering /V option)
Remote ON/OFF Control
-
Low=On, Open=Off (/P option: Low=Off, Open=On)
Operating Temperature
(*5)
C
Ta= -40º - +85º (100ºC /B Option)
Cooling
(*5)
-
Convection Cooled / Forced Air Cooled
Isolation Voltage
-
Input-Output : 1.5kVDC for 1min
Shock
-
196.1m/s
2
Weight (Typ.)
g
50
Vibration
-
Non Operating, 10-55Hz (Sweep for 1min.)
-
Amplitude 0.825mm Constant (Maximum 49.0m/s
2
) X, Y, Z 1 hour each
Size (W×H×D)
in
1.45 x .33 x 2.3; .5 height (/B Option)
Warranty
-
2 years
Industry Standard footprint/pinout
Allows for multi-sourcing
ASIC Design
Reduces number of components
Wide Range Operating Temperature (-40 to
100°C
)
Supports Harsh Wireless Operating Environment
High Efficiency 89% at 3.3V (PAQ100)
Reduce footprint area/Operation without heatsink
Feature
Benefit
Central Office:
ATM, Sonet, DSL, ISDN, Frame Relay, WDM
Broadband:
Switching Equipment, Routers
Wireless/Celluar:
Micro Cells (larger in size/10 sq. mi.)
Pico Cells (smaller in size/1 to 2 sq. mi.)
Remote Electronics: Fixed Local Loop, Fiber Optic
Transmission, Microwave Transmission,
Wireless Local Loop
Customer Premise: PBX, PABX, Datacomm, Voice Systems,
Video Conferencing
Industrial
ATE Test Equipment & Semi-Fab
Low Voltage Outputs (1.2-5.0V)
High Power Density up to 90.4W/in3
Industry Standard Footprint & Pinouts
Safety Agency Approvals (UL1950, CSA22.2, CE, TUV)
Constant Current Limit (Auto Restarting)
Remote On / Off (Positive/Negative Logic Available)
ASIC Design to Reduce Component Count
K e y M a r ke t S e g m e n t s & A p p l i c a t i o n s
PAQ
F e a t u r e s a n d B e n e f i t s
Quarter Brick Power Supply Specifications
S p e c i f i c a t i o n s
Notes:
*1. At 48VDC, maximum output current, Air Velocity = 2m/s and Ta = +25°C.
*2. 36 - 76VDC, constant load.
*3. No load - Full load, constant input voltage.
*4. External components are needed for operation.
*5. Refer to installation manual (website). PAQ100 Series
3055 Del Sol Blvd San Diego, CA 92154 1-800-LAMBDA-4
PAQ100 Openframe Drawing
PAQ100 Baseplate Drawing
1
-Vin
Negative Input Terminal
2
CNT
ON/OFF Control Terminal
3
+Vin
Positive Input Terminal
4
-V
Negative Output Terminal
5
-S
Negative Remote Sensing
6
TRM
Output Voltage Adjustment Terminal
7
+S
Positive Remote Sensing
8
+V
Positive Output Terminal
PIN#
Label
Function
PAQ S e r i e s O u t p u t s
Blank
Manual Reset after OVP or OCP condition
/V
Auto Reset after OVP or OCP condition
/P
Positive Logic Remote On/Off
/B
Baseplate version
/V, /PV, /BV, /BPV are Standard US stock items.
Suffix
Description
PAQ S e r i e s O p t i o n s
PAQ
1 0 0 D e r a t i n g C u r v e
Revision
A3: May 2002
For Additional Information, please visit www.lambdapower.com/products/paq-series.htm
Note: Open Frame PAQ100S48-3.3/V unit shown.