Catalog number
K-56715-20
Range
pH
2.00 to 16.00
mV
1000 to 1000
Temperature
14.0 to 257.0°F (10.0 to 125.0°C)
Resolution pH
0.01
mV
1°F / °C
Temperature
0.1
Accuracy pH
±0.01
mV
±1
Temperature
±1.0°F (±0.5°C)
Temperature compensation
Automatic or manual
Control type
On/off (limit), proportional, proportional-integral (PI)
Number of set points
2
Dead band
Independently selectable (high/low)
Display
Dual-line backlit LCD
Output
Alarm
One SPDT relay
Relay
Two SPST (hi/low)
Current
Two channels (0/4 to 20 mA)
Wash
One SPST relay
Power
80 to 250 VAC/DC, 50/60 Hz
Housing
NEMA 4X, IP66
Dimensions
5.67" W x 5.67" H x 4.39" D (144 x 144 x 112 mm)
Price
Catalog number
K-56715-50
K-56715-60
Type
Differential pH
Differential ORP, platinum sensor
Range
0 to 14 pH
1000 to 1000 mV
Reference
PVDF and ceramic, double junction
Reference electrolyte
Standard cell solution
Operating temperature
23 to 203°F (5 to 95°C)
Pressure tolerance
100 psig at 212°F (100°C)
Temperature sensor
300 NTC
Potential matching pin
316 stainless steel
Material
CPVC
Thread
1
1
2
" NPT(M)
Cable
Integral 10 ft (3 m)
Connector
Tinned ends
Length (excludes cable)
6.01" (153 mm)
Diameter (external)
1.90" (48 mm)
Price
l
Two control, one wash, and one alarm relay for more
accurate control
l
On/off (limit), proportional, or proportional-integral (PI) control
l
Replaceable reference solutions and salt bridges
extend electrode life
The advanced
1
2
-DIN pH 2000D has all of the benefits of the
advanced pH 2000, but with the additional ability to accept
differential pH or ORP electrodes.
Rugged NEMA 4X (IP66) enclosure can be wall, panel, or post-
mounted for installation in almost any industrial application.
The unit has a large dual-line, backlit LCD that can be adjusted
to display in any lighting condition. The controller can be
operated on 85 to 250 VAC/DC power sources for greater
installation flexibility.
Easily program the controller through the front-panel keypad
and intuitive menus. The controller can be programmed for
on/off (limit), proportional, or proportional-integral (PI) control
with either pulse length or pulse frequency operators. Differential
operation is ideal in situations where electrical noise may cause
problems.
Two control relays can be independently programmed for set
point, delay, and hysteresis to provide extreme control flexibility
in any application. The controller also has a wash relay that can
be programmed for interval and duration to keep the electrode
operating properly. An alarm relay, with programmable delay,
is also included to activate if the set point has been exceeded.
Two-level password protection prevents unauthorized tampering
with settings.
Use controller with differential electrodes to reduce the chance
of reference electrode fouling; order separately at right.
Controller also accepts pH electrodes with 100 or 1000 Pt RTD,
tinned-end temperature sensorssee pages 13001309.
56715-20
56715-50
Specifications & Ordering Info
Differential Electrodes
The differential pH and ORP electrodes are
ideal for industrial applications. Differential
measurement technology minimizes ground
loop interferences that can affect standard
electrodes. In addition, a built-in pre-amplifier
allows cable extensions up to 300 feet. Replaceable
heavy-duty quad junction salt bridges and refillable
reference solution extend the life of the sensor in
severe applications, reducing the cost of ownership.
Electrodes have 1
1
2
" NPT(M) threads on both ends for in-line
or submersible mounting. A 300 NTC temperature sensor
allows the electrodes to be used as direct replacements for
existing GLI electrodes.
pH 2000D Advanced
1
2
-DIN Differential pH/ORP Controller
Differential technology is more robust in industrial measurements
Replaceable salt bridge
increases electrode life.
Accessories
K-56715-52
Replacement salt bridge, protected CPVC
K-56715-54
Reference solution, 500 mL
K-50001-00
Power cord; U.S. standard plug, 6 ft, 120 VAC
Transmitters
P
H
pH Control