SS-APT
r LED design provides
360° viewing angle.
Built-in tamper-resistant feature.
Sealed against back pressure.
Constructed of off-white Bayblend®,
designed to commercial standards,
and offers an attractive appearance.
94-5V plastic flammability rating.
SEMS screws for wiring of the
separate base.
Several base options, including relay,
isolator, and sounder.
Remote test feature from the panel.
Built-in functional test switch acti-
vated by external magnet.
Capable of heat-only alarm mode,
enabled by a special command from
the panel. Smoke alarms are ignored.
Low-temperature signal at 45°F +/
10°F (7.22°C +/ 5.54°C).
Listings
Listings and approvals below apply to
the SS-APT Acclimate
TM
Multi-Sensor
Low-Profile Intelligent Addressable
Smoke detectors. In some cases,
certain detectors may not be listed by
certain approval agencies, or listing
may be in process. Consult factory for
latest listing status.
UL Listed: file S1195.
CSFM approved: file 7272-1288:165.
MEA approved: file 275-02-E Vol. IV.
SS-APT
Acclimate Multi-Sensor Smoke Detector
Low-Profile, Intelligent, Addressable
Acclimate is a trademark of System Sensor.
Bayblend® is a registered trademark of Bayer Corporation.
SS-APT in SS-B6 base
6937pho1.jpg
Description
Gamewells SS-APT Accli-
mate detector is an intelligent,
addressable, multi-sensing, low-
profile detector designed for use
with any 600 series Smart<i>Scan
TM
SLC panel.
The Acclimate detector uses a
combination of photoelectric and
thermal sensing technologies
that are designed to increase im-
munity to false alarms. Unlike
traditional intelligent detectors,
the Acclimate detector has a microprocessor in the detector head that processes
alarm data. As a result, the Acclimate detector adjusts its sensitivity automatically,
without operator intervention or control panel programming.
Areas where the Acclimate detector is especially useful include office complexes,
schools, college campuses, manufacturing and industrial facilities, and anywhere
else the use of a particular area may change. The Acclimate detector automatically
adjusts its sensitivity to acclimate itself to the environment.
Installation
The SS-APT plug-in detector uses a separate base to simplify installation, service,
and maintenance. A special tool allows maintenance personnel to plug-in and re-
move detectors without using a ladder. Mount base on an electrical backbox at least
1.5" (3.81 cm) deep. Suitable mounting back boxes include:
4.0" (10.16 cm) square box.
3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box.
Single-gang box (except for relay or isolator base).
With B501BH or B501BHT base, use a 4.0" (10.16 cm) square box.
With B224RB or B224BI base, use a 3.5" (8.89 cm) octagonal box, or a 4.0"
(10.16 cm) octagonal or square box.
NOTES: 1) Because of the inherent supervision provided by the SLC loop, end-
of-line resistors are not required. Wiring T-taps or branches are permitted for
Style 4 (Class B) wiring. 2) When using relay or sounder bases, consult SS-LI
data sheet for device limitations between isolator modules and isolator bases.
APPLICATION NOTE: The SS-APT detector has the unique ability to adjust sensitiv-
ity according to the environment, based on heat and smoke levels. Avoid installing
these detectors in locations that are susceptible to rapid and high temperature
changes. An example of an incorrect application would be near or in line with the
output of a self-contained heater.
DETECTOR SPACING: Gamewell recommends spacing detectors in compliance with
NFPA 72. In low airflow applications with smooth ceilings, space detectors 30 feet
(9.144 m). For specific information regarding detector spacing, placement, and spe-
cial applications, refer to NFPA 72. System Smoke Detector Application Guide, docu-
ment A05-1003, is available at systemsensor.com.
SS-APT
CS-2462 09/01/06
Page 2 of 2
Gamewell-FCI
12 Clintonville Road
Northford, CT 06472-1610
Phone: 203-484-7161
Fax: 203-484-7118
www.gamewell-fci.com
A Honeywell Company
© 2006 Gamewell-FCI
Specifications and wiring information are provided for information only and are believed
to be accurate. Gamewell-FCI assumes no responsibility for their use.
Data and design are subject to change without notice. Installation and wiring instructions
shipped with the product shall always be used for actual installation. For more
information, contact Gamewell-FCI.
Specifications
Product Line Information
Wiring Diagrams
SS-APT: Low-profile intelligent multi-
smoke detector. Must be mounted to one
of the bases listed below.
Bases:
SS-B6: Standard U.S. low-profile base, UL
Listing.
B501BP: Standard European flangeless
base, pkg. of 10.
B501BH: Sounder base, includes B501
base above.
B501BHT: Same as B501BH, but includes
temporal sounder.
B224RB: Intelligent relay base.
B224BI: Intelligent isolator base. Isolates
SLC from loop shorts.
Accessories:
RA400Z: Remote LED annunciator. 3 32
VDC. Fits U.S. single-gang electrical box.
Supported by SS-B6 and B501 bases only.
SMK400: Surface mounting kit provides for
entry of surface wiring conduit. For use with
B501 base only.
RMK400: Recessed mounting kit. For use
with B501 base only.
SMB600: Surface mounting kit for use with
SS-B6.
BCK-200B: Black detector covers, box of 10.
M02-04-01: Test magnet.
M02-09-00: Test magnet with telescope
stick.
Sensitivity
Auto-adjusting levels
1 to 2, 2 to 3, and 3 to 4%/ft.
Fixed-sensitivity levels: 0.5, 1, 2, 3, and
4%/ft.
Size
2.1" (5.3 cm) high x 4.1" (10.4 cm)
diameter installed in B501 base, 6.1"
(15.5 cm) diameter installed in SS-B6
base.
Shipping weight
5.2 oz. (147 g).
Operating temperature
0°C to 38°C (32°F to 100°F).
UL-Listed velocity range
0 4000 ft./min. (1219.2 m/min.), suitable
for installation in ducts.
Relative humidity
10% 93% noncondensing.
Thermal sensing rating
Fixed-temperature setpoint 135°F (57°C).
ELECTRICAL SPECIFICATIONS:
Voltage range
15 32 volts DC peak.
Standby current (max. avg.)
250 µA @ 24 VDC (without communica-
tion); 360 µA @ 24 VDC (one communi-
cation every 5 seconds with LED en-
abled).
Loop resistance
40 ohms maximum; varies according to
control panel used. Refer to panel
installation manuals.
LED current (max.)
6.5 mA @ 24 VDC (ON).
BASES AVAILABLE:
SS-B6: 6.1" (15.5 cm) diameter.
B501: 4.1" (10.4 cm) diameter.
B501BH or B501BHT: Sounder base
assembly. Includes B501 base.
B224RB Relay Base: Screw terminals:
up to 14 AWG (2.0 mm²). Relay type:
Form-C. Rating: 2.0 A @ 30 VDC
resistive; 0.3 A @ 110 VDC inductive; 1.0
A @ 30 VDC inductive. Dimensions: 6.2"
(15.748 cm) x 1.2" (3.048 cm).
B224BI Isolator Base: Dimensions: 6.2"
(15.748 cm) x 1.2" (3.048 cm). Maxi-
mum: 25 devices between isolator bases.
XR2B: Detector removal tool. Allows in-
stallation and/or removal of the SS-APT
Series detector heads from base in high
ceiling installations.
T55-127-000: Detector removal tool with-
out pole.
XP-4: Extension pole for XR2B. Comes
in three 5-ft. sections.
Detector Guards:
NOTE: The following guards are not UL
listed with the SS-APT. Consult with lo-
cal AHJ.
STI 9601: Low-profile, flush-mount smoke
detector guard, wire.
STI 9602: Low-profile, surface-mount,
smoke detector guard, wire.
STI 9609: High-profile, flush-mount, smoke
detector guard, wire.
STI 9605: High-profile, surface-mount,
smoke detector guard, wire.
STI 9604: Flush-mount heat detector
guard, wire.
STI 9610: Surface-mount heat detector
guard, wire.
STI-8200-SS: Flush-mount stainless
steel smoke detector guard.
STI-8230-SS: Surface-mount stainless
steel smoke detector guard.
Address dial on back of detector.
4762wir1.tif