eat W ave L abs, Inc.

and properly grounded.
Always disconnect power to the instrument before
opening the enclosure or making any wiring changes.

Caution: Additionally, this device is intended to control heaters and
thermal systems, which may be hot and/or dangerous.
Beware that damage to heaters and other equipment,
possibly resulting in personal injury or death may result
from improper use or control of thermal systems.

Understand the safety implications of your system and
take proper precautions to avoid damage to property or
injury to personnel.

Where to Get More Information

This owners manual represents the most current information at the time it was published;
for the latest information, please visit our website:
www.cathode.com
.

We may also be reached in the following ways:

HeatWave Labs, Inc.
195 Aviation Way, Suite 100
Watsonville, CA 95076-2069
Tel: 831-722-9081
Fax: 831-722-5491
Email: techsales@cathode.com
Warranty and Repair Information
Our products are warranted against defects in materials or workmanship according to our
Standard Product Warranty, TB-166
. iii
Model 101303-23 Specifications Model
101303-23
Model 101303-23 Specifications
Ramp and soak programmability
with storage for 2 profiles, with
up to 8 steps per profile
Autotuning PID control; also
supports manual tuning and other
control modes, including alarm
mode
Solid-state control utilizing an
oversized solid-state relay for
long-life and precise control
Phase-angle fired SCR for use
with tungsten heating elements
Inductively coupled load for use
with 8, 16 or 32 volt loads. See
Factory Configuration in
Appendix A.
Over-temperature protection
utilizing a separately controlled
alarm setpoint and an independent
mechanical relay in series with the
solid state control relay
Internal SCR is short-circuit
protected by a back-panel
accessible semiconductor fuse
(HWL p/n 101960-01, FWH-
020A6F)
Over-current protection using a
front panel circuit breaker
Open loop protection, shutting
down output if open loop
operation is detected (factory
preset with open loop off)
Dual LED displays on control
module for simultaneous indication
of process temperature and setpoint
in Fahrenheit or Celsius (default)
Input power: 100-130 VAC, or
230/240 VAC, 50/60 Hz. See Factory
Configuration in Appendix A

Output power:

See Factory Configuration in
Appendix A
Display resolution: 1°
Absolute accuracy: ±1°
Heater connector: 3-pin screw
terminal, including ground conductor
Type K thermocouple sensor input

range: 0 to 1370°C

ambient rejection: <0.1°C/°C

connector: standard Type-K

Enclosure: standard EIA 19 EIA
rackmount, 7.0 tall (5 rack units),
14 deep, 44 lbs.
Ambient temperature range: 0 to
60°C, non-condensing
Watlow is a registered trademark of Watlow Electric Manufacturing Co. Model 101303-23

Table of Contents
Important Safety Notice ........................................................................................ ii

Where to Get More Information............................................................................ ii

Warranty and Repair Information ......................................................................... ii

Model 101303-23 Specifications ......................................................................... iii

Overview ................................................................................................................2

Control Module Displays and Menu Navigation ...................................................3

Limit Module Displays and Menu Navigation.......................................................4

Getting Started .......................................................................................................5

Programming and Executing Profiles ....................................................................9

Programming a Profile.......................................................................................9

Running a Profile.............................................................................................11

Resuming a Halted Profile...............................................................................11

Using the Wait-for Process Deviation Function ..............................................11

Advanced Features and Settings ..........................................................................12

Setting the autotune point to a lower value......................................................12

Switching between Celsius and Fahrenheit .....................................................12

Changing the resolution (decimal point)..........................................................12

Power limiting .................................................................................................13

Other features...................................................................................................14

Error Messages and Troubleshooting...................................................................15

Error messages.................................................................................................15

Troubleshooting...............................................................................................15

Appendix A: Default Factory Configuration.......................................................17

Input voltage settings ...........................................................................................19

Output voltage settings ....................................................................................19

8V output with 120V input...................................................................................20

Appendix B: Model 101303-23 Electrical Schematic.........................................21
2
Overview

Model 101303-23

Overview

The HeatWave Labs Model 101303-23 is a full featured, high quality rackmount
temperature controller designed for low-voltage tungsten heater control applications
requiring precise, reliable control and ramp/soak programmability.

Over-temperature protection is provided by a completely independent limit
controller and sensor. The alarm will disable power to the heater if the alarm
setpoint is exceeded. Alarm switching is provided by an independent, internal
mechanical relay in series with the solid-state control relay. This alarm scheme
provides protection against system runaway if the solid-state relay should fail in the
closed position. In addition to over-temperature protection, the Model 101303-23
provides other mechanisms like open loop and open sensor detection to assist in
system protection. The phase-angle fired SCR is protected by a semiconductor fuse
that can be replaced via back-panel access.
3
Control Module Displays and Menu Navigation

Model 101303-23
Control Module Displays and Menu Navigation

The Watlow® Series 96 Controller with the ramping software option allows
programming of 2 temperature vs. time profiles (called files) that can each have up
to eight distinct steps programmed into them. Upon power-up, the unit starts at the
Home Page and indicates the process temperature in the upper display and the
setpoint (or
) in the lower display. While not running a profile, the setpoint
can be directly adjusted with the up and down arrow keys. The setpoint is registered
about 2 seconds after the last pressing of either up or down arrow.
Management, programming, and execution of temperature vs. time profiles are
explained in the Programming and Executing Profiles section.
































Figure 1 Control module keys and displays
LEDs 1 to 4:
1. Illuminated when heater output is active. For example, it will be
on continuously when the heater is at 100% power, and on half
the time when the heater is at 50% power.
2. Not used.
3. Illuminated when the over-temperature alarm has been activated.
4.
Not used.
Advance Key:
When at the home page, pressing this
key will open the programming menu.
If in other menus, this key selects the
menu choice in the upper display,
scrolls through menu selections, or
will scroll through parameter values in
the lower display.

Infinity/Home Key:
From the home page, pressing once opens
the Pre-run menu; pressing again starts
the profile and opens the Run menu.
If not at the home page, pressing this key
will exit the menu system and return to the
home page.

Up and Down Keys:
Pressing up or down alone
changes the setpoint or
parameter value.
Pressing them
simultaneously for 3 seconds
accesses Operations Page.
If held for 3 more seconds,
accesses Setup Page. See
Watlow Series 96 Users
Manual for full description of
Operations and Setup Pages.

Upper Display:
Indicates process
temperature, or
parameter value
when in menus.

Lower Display:
Indicates process
setpoint, or
parameter name
when in menus.
Profile Indicator:
Illuminated when controller
has been set to manual
mode, where Upper Display
indicates percent output.

Watlow is a registered trademark of Watlow Electric Manufacturing Co. 4
Limit Module Displays and Menu Navigation

Model 101303-23

Limit Module Displays and Menu Navigation

The Watlow® Series SD Limit Controller mo