SUPERtrol II
>
SUPERtrol II
Kessler-Ellis Products 800-631-2165
F-16 Flow Instruments
Page 75
Flow Instruments
FLOW
COMPUTERS
Multi-Function Flow Computer
EZ Setup- Guided Setup for First Time Users
Liquid, Gas, Steam and Heat Flow Equations
Utility Metering
Menu Selectable Hardware & Software Features
Internal Data Logging Option
Isolated Pulse and Analog Outputs Standard
RS-232 Port Standard, Modbus RTU RS-485
Optional
Windows Setup Software
NX19 Gas Equations, Stacked DP Transmitters
DDE Server & HMI Software Available
Remote Metering by Wireless or Modem and
TROLlink Remote Metering Software Available
SUPERtrol II
Description:
The SUPERtrol II Flow Computer satises the instrument
requirements for a variety of owmeter types in liquid, gas, steam
and heat applications. Multiple ow equations are available in a
single instrument with many advanced features.
The alphanumeric display offers measured parameters in easy to
understand format. Manual access to measurements and display
scrolling is supported
The versatility of the Flow Computer permits a wide measure of
versatility within the instrument package. The various hardware
inputs and outputs can be soft assigned to meet a variety of
common application needs. The user soft selects the usage of
each input/output while conguring the instrument. Consider the
following illustrative examples.
The isolated analog output can be chosen to follow the volume
ow, corrected volume ow, mass ow, temperature, pressure,
or density by means of a menu selection. Most hardware features
are assignable by this method.
The user can assign the standard RS-232 Serial Port for external
data logging, transaction printing, or for connection to a modem
for remote meter reading.
A Service or Test mode is provided to assist the user during start-
up system check out by monitoring inputs and exercising outputs.
The system setup can also be printed.
Specications:
Environmental
Operating Temperature: 0 to +50 C
Storage Temperature: -40 to +85 C
Humidity : 0-95% Non-condensing
Materials: UL, CSA, VDE approved
Display
Type: 2 lines of 20 characters
Types: Backlit LCD and VFD ordering options
Character Size: 0.3 nominal
User selectable label descriptors and units of measure
Keypad
Keypad Type: Membrane Keypad
Keypad Rating: Sealed to Nema 4
Number of keys: 16
Enclosure
Enclosure Options: Panel, Wall, Explosion Proof
Size: See Dimensions
Depth behind panel: 6.5 including mating connector
Type: DIN
Materials: Plastic, UL94V-0, Flame retardant
Bezel: Textured per matt nish
Power Input
The factory equipped power option is internally fused. An
internal line to line lter capacitor is provided for added
transient suppression. MOV protection for surge transient is
also supported
Universal AC Power:
85 to 276 Vrms, 50/60 Hz
DC Power Option:
24 VDC (16 to 48 VDC)
Power Consumption
AC Power:
6.5 V/A (6.5W)
DC Power:
300 mA max.
Flow Meter Types:
Linear: Vortex, Turbine, Positive Displacement, Magnetic,
GilFlo, GilFlo 16 point, ILVA 16 Point and others
Square Law: Orifice, Venturi, Nozzle, V-Cone, Wedge,
Averaging Pitot, Target and others
Multi-Point Linearization: May be used with all owmeter
types. Including: 16 point, UVC and dynamic
compensation.
Flow Inputs:
Analog Input:
Accuracy: 0.02% FS at 20° C
Ranges
Voltage: 0-10 VDC, 0-5 VDC, 1-5 VDC
Current: 4-20 mA, 0-20 mA,
4-20 mA stacked, 0-20 mA stacked
Basic Measurement Resolution: 16 bit
Update Rate: 4 updates/sec
Automatic Fault detection: Signal over/under-range,
Current Loop Broken
Calibration: Operator assisted learn mode
Extended calibration: Learns Zero and Full Scale of each
range
Fault Protection:
Fast Transient: 500 V Protection (capacitive clamp)
Reverse Polarity: No ill effects
Over-Voltage Limit: 50 VDC Over voltage protection
Over-Current Protection: Internally current limited
protected to 24VDC
Page 76 Flow Instruments F-16
Kessler-Ellis Products 800-631-2165
Flow Instruments FLOW
COMPUTERS
Pulse Inputs:
Number of Flow Inputs: one
Input Impedance: 10 k nominal
Trigger Level: (menu selectable)
High Level Input
Logic On: 2.5 to 30 VDC
Logic Off: 0 to 2 VDC
Low Level Input (mag pickup)
Selectable sensitivity: 10 mV and 100 mV
Minimum Count Speed: 0.25 Hz (to maintain rate display)
Maximum Count Speed: Selectable: 0 to 50 kHz
Overvoltage Protection: 50 VDC
Update Speed: 1 update/sec.
Temperature, Pressure, Density Inputs
The compensation inputs usage are menu selectable for
temperature, temperature 2, pressure, density or not used.
Calibration: Operator assisted learn mode
Operation: Ratiometric
Basic Measurement Resolution: 16 bit
Update Rate: 2 updates/sec minimum
Automatic Fault detection:
Signal Over-range/under-range
Current Loop Broken
RTD short
RTD open
Reverse Polarity: No ill effects
Over-Current Limit
(current input) Internally limited to protect input to 24
VDC
Available Input Ranges
Current: 4-20 mA, 0-20 mA
Resistance: 100 Ohms DIN RTD
Accuracy: 0.02% FS at 20° C
100 Ohm DIN RTD (DIN 43-760, BS 1904):
Three Wire Lead Compensation
Internal RTD linearization learns ice point resistance
1 mA Excitation current with reverse polarity protection
Temperature Resolution: 0.1°C
Temperature Accuracy: 0.5°
Stored Information (ROM)
Steam Tables (saturated & superheated),
Fluid Properties: Water, Air, Natural Gas, A Variety of User
Entered Industrial Fluids or Generic
User Entered Stored Information (EEPROM / Nonvolatile
RAM)
Transmitter Ranges, Signal Types
Fluid Properties
(reference density, expansion factor, specic heat,
viscosity, isentropic exponent, combustion heating
value, Z factor)
Units Selections (English/Metric)
Language Translations (optional)
Excitation Voltage
24 VDC @ 100 mA (fault protected with self resetting fuse)
Relay Outputs
The relay outputs usage is menu assignable to (Individually for
each relay) Hi/Lo Rate Alarm, Hi/Lo Temperature Alarm, Hi/Lo
Pressure Alarm, Pulse Output (pulse options), Wet Steam or
General purpose warning (security).
Number of relays: 2 (3 optional)
Contact Style: Form C contacts (Form A with 3 relay option)
Contact Ratings: 240 V, 5 amp
Analog Outputs
The analog outputs are menu assignable to correspond to the
Uncompensated Volume Rate, Corrected Volume Rate, Mass
Rate, Heat Rate, Temperature, Density, Pressure or Delta
Temperature.
Number of Outputs: 2
Type: Isolated Current Sourcing (shared common)
Available Ranges: 0-20 mA, 4-20 mA (menu selectable)
Resolution: 16 bit
Accuracy: 0.05% FS at 20 Degrees C
Update Rate: 5 updates/sec
Temperature Drift: Less than 200 ppm/C
Maximum Load: 1000 ohms
Compliance Effect: Less than .05% Span
60 Hz rejection: 40 dB minimum
EMI: No effect at 3 V/M
Calibration: Operator assisted Learn Mode
Averaging: User entry of DSP Averaging constant to cause
a smooth control action
Listing:
CE Compliant, UL/C-UL Pending
Serial Communication
The serial port can be used for printing, datalogging, modem
connection, two way paging and communication with a
computer.
RS-232:
Device ID: 01-99
Baud Rates: 300, 600, 1200, 2400, 4800, 9600, 19200
Parity: None, Odd, Even
Handshaking: None, Software, Hardware
Print Setup: Congurable print list and formatting
RS-485: (optional 2nd COM port)
Device ID: 01-247
Baud Rates: 300, 600, 1200, 2400, 4800, 9600, 19200
Parity: None, Odd, Even
Protocol: Modbus RTU (Half Duplex)
Data Logging
The data logger captures print list information to internal storage
for approximately 5000 transactions. This information can be
used for later uploading or printing. Storage format is selectable
for Comma-Carriage Return or Printer formats.
Isolated Pulse output
The isolated pulse output is menu assignable to Uncompensated
Volume Total, Compensated Volume Total, Heat Total or Mass
Total.
Pulse Output Form (menu selectable): Open Collector NPN or
24 VDC voltage pulse
Nominal On Voltage: 24 VDC
Maximum Sink Current: 25 mA
Maximum Source Current: 25 mA
Maximum Off Voltage: 30 VDC
Saturation Voltage: 0.4 VDC
Pulse Duration: User selectable
Pulse output buffer: 8 bit
Fault Protection
Reverse polarity:
Shunt Diodes
Over-current Protected
Over-voltage Protected
Real Time Clock
The Flow Computer is equipped with a pseudo nonvolatile real
time clock with display of time and date.
Format:
24 hour format for time
Day, Month, Year for date
Kessler-Ellis Products 800-631-2165
F-16 Flow Instruments
Page 77
Flow Instruments
FLOW
COMPUTERS
5.67 (144)
2.83
(72)
6.15 (156)
0.5
(13)
0.28 (7.2)
3.43
(87)
6.18 (157)
Dotted Line Shows Optional Bezel Kit
Panel
Cutout
5.43
(138)
2.68
(68)
Dimensions are in inches (mm)
0.4 (10)
RATE
TOTAL 267395.749 GPM
GAL
147.43
Fig. 1: Standard Dimensions
1.10
(28) 1.10
(28)
7.8 (198)
5.7 (145)
0.59
(14)
0.75 Conduit Knockouts
(5 places)
1.06
(27)
9.4 (238)
7.3 (184)
2.34 (59.5)
8.4 (213.4)
4.13 (105)
2.33 (59)
0.385
(9.8)
Security Tag
Provisions
1.10
(28)
1.10
(28)
1.10
(28) 1.10
(28) 1.10
(28)
1.10
(28)
0.472
(12)
0.75
(19)
0.63
(16)
Terminal Layout
Terminal Designations
Ordering Information
Example ST2
L
1
0
P
M
Series:
ST2 = Flow Computer
Display Type:
L= LCD
V= VFD
Input Power:
1= 85 to 276 VAC
3= 24 VDC (16 to 48 VDC)
Network Card:
0= None
1= RS485/Modbus (optional 2nd COM port)
Mounting:
P= Panel Mount ........................................................ (see Fig. 1)
N= NEMA 4 Wall Mount .............................(see NEMAtrolST4X)
W= NEMA 12/13 Wall Mount w/ Clear Cover ............ (see Fig.2)
E= Explosion