SECTION 1 – TERMS AND DEFINITIONS TABLE OF CONTENTS
%>
Yahoo! is not affiliated with the authors of this page or responsible for its content.
SECTION 1 TERMS AND DEFINITIONS TABLE OF CONTENTS
Section 49
Signals, Lighting and Electrical Systems
FINAL 091407
City of Elk Grove
Standard Construction Specifications
49-0
SECTION 49 SIGNALS, LIGHTING AND ELECTRICAL SYSTEMS
TABLE OF CONTENTS
Section
Page
49-1
GENERAL
49.3
49-1.01
Definitions
49.3
49-1.02
Abbreviations
49.3
49-1.03
Regulation and Code
49.3
49-1.04
Equipment List and Drawings
49.3
49-1.05
Ordering of Signal and Lighting Equipment
49.3
49-1.06
Maintaining Existing and Temporary Electrical Systems
49.4
49-1.07
Scheduling of Work
49.4
49-1.08
Safety Precautions
49.5
49-1.09
Inspection
49.5
49-1.10
Signal Turn-On
49.5
49-2
MATERIALS AND INSTALLATION
49.5
49-2.01
Trench Excavation and Backfill
49.5
49-2.02
Removing and Replacing Improvements
49.5
49-2.03
Foundations
49.6
49-2.04
Standards, Steel Pedestals and Posts
49.6
49-2.04.A Aluminum and Concrete Street Light Standards
49.6
49-2.04.B Placement of Standards, Enclosures, Posts and Associated Devices
49.7
49-2.04.C Final Location of Traffic Signal
Poles
49
.7
49-2.05
Conduit
49.7
49-2.06
Pull Boxes
49.10
49-2.07
Conductors
49.12
49-2.07.A Signal Interconnect Cable
49.12
49-2.07.B Interconnect Cable Testing After Installation
49.13
49-2.08
Wiring
49.13
49-2.9
Bonding and Grounding
49.13
49-2.10
Service
49.14
49-2.10.A Metered Service (120/208 Volt, 120/240 Volt)
49.14
49-2.10.B Metered Service with Encapsulated Step-Down Transformer (277/480 Volt to
120-240 Volt)
49.15
49-2.10.C Unmetered Service (120/208 Volt, 120/240 Volt)
49.16
49-2.10.D Unmetered Service (277/480 Volt)
49.17
Section 49
Signals, Lighting and Electrical Systems
FINAL 091407
City of Elk Grove
Standard Construction Specifications
49-0
49-2.10.E Unmetered Service with Encapsulated Step-Down Transformer (277/480 Volt to
120/240 Volt)
49.17
49-2.11
Testing
49.18
49-2.12
Painting
49.18
49-3
CONTROLLER ASSEMBLIES
49.19
49-4
TRAFFIC SIGNAL FACES AND FITTINGS
49.19
49-4.01
Vehicle Signal Faces
49.19
49-4.02
Programmable Directional Louvers
49.19
49-4.03
Backplates
49.19
49-4.04
Pedestrian Signal Heads
49.19
49-4.05
Audible Pedestrian Signals
49.20
49-5
DETECTORS
49.20
49-5.01 Vehicle Detectors
49.20
49-5.01.A Construction Materials
49.21
49-5.01.B Installation Details
49.21
49-5.02
Opticom Cable and Detectors
49.24
49-5.03
Pedestrian Push Buttons
49.24
49-6
LIGHTING
49.24
49-6.01
High Pressure Sodium Luminaires
49.24
49-6.02
Lamps and Ballasts
49.25
49-6.03
Internally Illuminated Street Name Signs
49.25
49-6.04
Photoelectric Controls
49.27
49-6.04.A Photoelectric
49.27
49-6.04.B Contactors
49.27
49-6.04.C Contactor and Test Switch Housing
49.27
49-6.04.D Wiring
49.27
49-7
PROJECT-SUPPLIED EQUIPMENT
49.27
49-8
REMOVING AND SALVAGING ELECTRICAL EQUIPMENT
49.28
49-9
PAYMENT
49.28
Section 49
Signals, Lighting and Electrical Systems
FINAL 091407
City of Elk Grove
Standard Construction Specifications
49-3
SECTION 49
SIGNALS, LIGHTING AND ELECTRICAL SYSTEMS
49-1
GENERAL
Traffic signals, intersection safety lighting and electrical systems shall be constructed or installed as
shown or specified in the Contract, these Specifications, the applicable State Plans, and the applicable
provisions of Section 86, Signals, Lighting and Electrical Systems, of the State Specifications.
The provisions of Section 7-19, Substantial Completion, of the City Construction Specifications shall not
apply.
49-1.01
Definitions
Definitions for signals, lighting and electrical systems shall be as specified in Section 86-1.015,
Definitions, of the State Specifications, and the following:
Programmed Visibility Signal Head - A type of signal head that can be optically programmed to
restrict visibility of indication(s) to only those areas or lanes designated.
Signal Standard - Any pole which supports signal head(s).
Street Light Standard - The pole, and mast arm if required, which supports the luminaire.
49-1.02
Abbreviations
Abbreviations for signals, lighting and electrical systems shall be as specified on page ES-1A of the State
Plans, and the following:
EVD - Emergency Vehicle Detector
I/C - Interconnect Cable
L.C. - Lower Case
PG&E -Pacific Gas & Electric Company
SMUD -Sacramento Municipal Utility District
U.C. - Upper Case
49-1.03
Regulation and Code
Section 86-1.02 of the State Specifications is amended to state that any City amendments to the identified
codes shall be applicable.
49-1.04
Equipment List and Drawings
If requested by the City, the Contractor shall submit for review sample articles of the material
proposed for use. After review, said sample articles will be returned. The Contractor shall include on the
equipment list the installation location of material supplied. This shall be done by the use of street
names, the alphabetical letter designation used on the Plans, or a location as otherwise noted on the Plans.
Equipment lists and drawings shall conform to Section 86-1.04, E q uipment List and Drawings, of the
State Specifications.
The equipment and materials proposed for use on any project shall be approved by the City before
starting work.
In conformance with the requirements in Section 11-3, Record Drawings, of these Specifications, the
Contractor shall maintain record drawings that shall show in detail the construction changes of all traffic signal
and streetlight wiring, conduits, standards, and associated equipment. In particular, the record drawings
shall accurately depict the location and depth of conduits, location of standards, pull boxes, wiring changes,
and all applicable manufacturers operation and maintenance information.
49-1.05
Ordering of Signal and Lighting Equipment
The Contractor shall place the order for long lead-time signal and lighting equipment not provided by
the City within five (5) days of receiving notice that they have been awarded the Contract. The Contractor
shall submit a copy of the equipment order to the City. Liquidated damages, as set forth in Section 8-10,
Liquidated Damages for Delay, of these Specifications, shall apply in case of failure to comply. No
Section 49
Signals, Lighting and Electrical Systems
FINAL 091407
City of Elk Grove
Standard Construction Specifications
49-4
extension of time will be allowed for delay in delivery of traffic signal poles, street light standards, luminaries,
or traffic signal equipment. The City hereby guarantees payment for long lead-time equipment ordered
prior to execution of the Contract.
The Contractor shall furnish the City with a statement from the vendor(s) that the order for the electrical
material required for the contract has been received and accepted by said vendor(s). Said statement shall be
furnished within ten (10) days after receiving notice that the Contract has been executed for the City.
Said statement shall give the date that the electrical equipment will be shipped.
49-1.06
Maintaining Existing and Temporary Electrical Systems
Maintaining existing and temporary electrical systems shall conform to Section 86-1.06,Maintaining
Existing and Temporary Electrical Systems, of the State Specifications, except that paragraphs 3, 11, 12,
and 13 shall not apply.
Existing electrical systems, including traffic signals, traffic signal vehicle and pedestrian detection
facilities, traffic signal communication and monitoring facilities, street lighting facilities, flashing beacons and
sign illumination facilities, or approved temporary replacements thereof, shall be kept in effective operation
for the benefit of the traveling public during the progress of the Work, except when shutdown is permitted
to allow for alterations or final removal of the systems.
The Contractor shall notify the City at least two (2) Working Days prior to performing any work on
existing systems, including any work that may take