Modicon Telemecanique Premium automation platform

pages 0451Q/2
and 0451Q/3
Discrete I/O
pages 43520/2 to 43520/13
Selection guide
pages 0471Q/2 to 0471Q/5
Premium
PLCs
Discrete I/O
Distributed I/O
Application-
specific modules
and solutions
PL7 software
and industrial
terminals
Operator
dialogue
terminals
Supervision
Communication
Services
TSX PAY safety modules
pages 43308/2 to 43522/7
Telefast 2 and Tego pre-wired system
pages 14030/2 to 15012/3
Selection guide
pages 0113Q/2 and 0113Q/7
Momentum distributed discrete I/O
pages 48220/2 to 48249/3
Selection guides
pages 0489Q/2 to 0489Q/5
pages 0491Q/2 and 0491Q/3
pages 0495Q/2 and 0495Q/3
pages 0488Q/2 to 0488Q/5
ISP Plus weighing system
pages 43552/2 to 43552/7
Counter and motion control modules
pages 43540/2 to 43545/3
Selection guides
pages 0452Q/2 to 0453Q/3
Analogue I/O and process control
pages 43530/2 to 43620/9
Selection guide
pages 0472Q/2 and 0472Q/3
Development and run-time software
pages 43099/2 to 43107/3
FT2100 industrial terminals
pages 43586/2 to 43586/5
Selection guide
pages 0454Q/2 and 0454Q/3
Magelis alphanumeric terminals
pages 36331/2 to 36351/3
Magelis terminals and graphic stations
pages 36352/2 to 36354/3
Selection guide
pages 0372Q/2 and 0372Q/3
Selection guide
page 0372Q/3
CCX 17 industrial operator panels
pages 43583/2 to 43583/7
Monitor Pro multi-platform software
Please consult your Regional Sales Office
X-Way communication architecture : Ethernet network, Fipway network, Jnet network, Modbus Plus network,
AS-i bus, Fipio bus, InterBus-S bus, Profibus DP bus, CANopen bus, Uni-Telway bus, Modbus/Jbus bus, Modem, asynchronous serial links
pages 43609/2 to 43615/3
Selection guide
pages 0477Q/2 to 0477Q/5
Technical information
pages 43900/2 to X0011/3
Addresses
pages A0000/2 and A0000/4
Partnership program
pages 43614/2 to 43614/11
AS-i bus module and power supplies
pages 43610/2 to 43612/3
TBX distributed I/O
pages 42311/2 to 42313/5
Selection guides
pages 0422Q/2 and 0422Q/3
pages 0424Q/2 and 0424Q/3
Warm Standby redundancy
pages 43566/2 to 43566/7 2
S0207/3
2 Discrete I/O
Contents
Discrete I/O
Selection guide
pages 0471Q/2 to 0471Q/5
Discrete I/O modules
TSX D
i
i
i
i
i
Y
pages 43520/9 and 43520/10
Safety modules
TSX PAY
page 43522/6
Telefast 2
Selection guide
pages 0113Q/2 and 0113Q/7
Telefast 2 pre-wired system
ABE-7
i
i
i
i
i
pages 14025/2 to 14040/2
Tego Dial
Installation system for dialogue components
APD-1
pages15003/2 and 15003/3
Tego Power
Installation system for motor starter components
APP-1
i
i
i
i
i
pages 15012/2 and 15012/3 0471Q/2
TSX DEY
TSX DEY
TSX DEY
TSX DEY
TSX DEY
TSX DEY
08D2
16D2
16D3
16A2
16A3
16A4
Premium automation platform
Discrete I/O modules
Discrete input and I/O selection guide
Connecting inputs to screw terminal blocks for bare wires or wires fitted with either cable ends or open/closed cable tags
(minimum cross-section 0.28 mm
2
, maximum 1.5 mm
2
)
a
a
or
c
c
24 V
48 V
24 V
48 V
100120 V
8 isolated chan.
16 isolated channels
Via 20-way screw terminals : TSX BLY 01
Type 2 Positive
Negative 2-wire
a
/
c
, 3-wire PNP
a
any type
2-wire
a
/
c
,
2-wire
a
/
c
3-wire NPN
a
any type
43520/9
Applications
Type
Voltage
Modularity
(number of channels)
Connection
Compatibility with
Telefast 2-sub-bases
Connection
sub-bases
Input adaptor
sub-bases
Compatibility with
systems
Tego Dial
Tego Power
Isolated inputs
IEC 1131-2
conformity
Logic
Proximity sensor
compatibility acc.
to IEC 947-5-2 standard
Isolated outputs
Fallback
IEC 1131-2 conformity
Protection
Logic
Type of discrete input
and I/O modules
Page 0471Q/3
TSX DEY
TSX DEY
TSX DEY
TSX DEY
TSX DEY
TSX DMY
TSX DMY
16A5
16FK
32D2K
64D2K
32D3K
28FK
28RFK
Connecting inputs to HE 10 connectors with preformed cables with flying leads
(cross-section 0.324 mm
2
), rolled ribbon cables (cross-section 0.08 mm
2
) or
multicore cables (cross-section 0.324 mm
2
).
Connecting I/O to HE 10 connectors with
preformed cables with flying leads (cross-section
0.324 mm
2
), rolled ribbon cables (cross-section
0.08 mm
2
) or multicore cables (cross-section
0.324 mm
2
).
a
200240 V
24 V
48 V
24 V
16 isolated inputs and 12 isolated outputs 0.5 A
16 fast isolated
32 isolated chan.
64 isolated chan.
32 isolated chan.
Event-triggered
Programmable reflex
channels
fast inputs
inputs and outputs
Via 20-way HE 10 connectors
8 or 16 channels, with or without LED, with common or 2 terminals per channel
16 channels
a
5 V TTL,
a
24 V,
a
48 V,
c
115 V or 230 V, 2 terminals per channel
Yes (see pages 15003/2 and 15012/2)
Type 1
Type 1
Positive
2-wire
a
/
c
, 3-wire PNP
a
any type
Output fallback may be configured, with continuous
monitoring of output control and output reset in
case of internal fault
Yes
Protected
Positive
43520/9
43520/10 0471Q/4
Premium automation platform
Discrete I/O modules
Discrete output selection guide
TSX DSY TSX DSY TSX DSY
TSX DSY
TSX DSY
TSX DSY TSX DSY
08T2
08T22
16T2
08T31
16T3
08R5
16R5
Applications
Type
Voltage
Current
Modularity
(number of channels)
Connection
Compatibility
with Telefast 2
sub-bases
Connection
sub-bases
Output adaptor
sub-bases
Compatibility with
systems
Tego Dial
Tego Power
Isolated outputs
Fallback
IEC 1131-2
conformity
Protection
Logic
Type of discrete
output module
Page
Connecting outputs to screw terminal blocks for bare wires or wires fitted with either cable ends or open/closed cable tags
a
transistor
a
or
c
relay
a
24 V,
24 V
48 V
c
24240 V
0.5 A
2 A
0.5 A
1 A
0.25 A
3 A (Ith)
8 channels, protected
16
channels,
8 channels,
16 channels,
8 channels,
16 channels,
protected
protected
protected
not protected
not protected
Via 20-way screw terminals : TSX BLY 01
Output fallback may be configured, with continuous monitoring of output control
Output fallback may be configured
and output reset in case of internal fault
Yes
Yes
Protected
Not protected
Positive 43520/9 0471Q/5
TSX DSY
TSX DSY
TSX DSY
TSX DSY
TSX DSY TSX DSY
TSX DSY
08R5A
08R4D
08S5
16S5
16S4
32T2K
64T2K
Connecting outputs to HE 10 connectors with preformed cables with flying
leads (cross-section 0.324 mm
2
), rolled ribbon cables (section 0.08 mm
2
) or
multicore cables (cross-section 0.324 mm
2
).
(minimum cross-section 0.28 mm
2
, maximum 1.5 mm
2
)
a
relay
c
triac
a
transistor
a
2448 V
c
24240 V
24120 V
48240 V
24120 V
24 V
2 A per
1 A per
1 A per
0.1 A per
5 A (Ith)
5 A (Ith)
channel
channel
channel
channel
8 channels, protected
16
channels,
16 channels,
32 channels, protected
64 channels, protected
protected
not protected
Via 20-way HE 10 connectors
8 or 16 channels, with or without LED, with common or 2 terminals per channel
8 or 16 relay channels with 1 N/O, 1 or 2 C/O or transistor,
a
548 V,
a
24 V,
c
24240 V, 1 or 2 terminals per channel
Yes (see pages 15003/2 and 15012/2) Output fallback may be configured, with continuous monitoring of output
control and output reset in case of internal fault
Yes
Yes
Yes
Protected
Not protected
Protected
Positive
43520/9 4 3 5 2 0 / 2
Premium automation platform
Discrete I/O modules
Connection principle
Connecting modules with screw terminal blocks
Discrete I/O module terminal blocks have a device for automatically transferring the coding when first used. This prevents
manipulation errors when a module is replaced. This coding ensures electrical compatibility for the type of module.
Each terminal can accept bare wires or wire with cable ends with open tags.
The capacity of each terminal is :
i
Minimum : 1 x 0.2 mm
2
wire (AWG 24) without cable end
i
Maximum : 1 x 2 mm
2
wire (AWG 14) without cable end or 1 x 1.5 mm
2
wire (AWG 15) with cable end
Screw connection terminal blocks are equipped with captive screws.
The maximum terminal block capacity is 16 x 1 mm
2
(AWG 17) wires + 4 x 1.5 mm
2
(AWG 15) wires.
Connecting modules with HE 10 connectors
Preformed cable with 20 wires,
22-gauge (0.324 mm
2
)
Used for simple and direct wire to wire
connection of the I/O of the module with
connectors
1
to the sensors,
preactuators or terminals.
This preformed cable
3
comprises :
i
An insulated HE10
2
connector at
one of the ends, with 20 x 0.34 mm
2
cross-section sheathed wires.
i
At the other end
4
, flying leads
differentiated by a colour code
conforming to standard DIN 47100.
TSX CDP 301 : 3 metres long
TSX CDP 501 : 5 metres long
TSX CDP 1001 : 10 metres long
Rolled ribbon cable with sheath,
28-gauge (0.08 mm
2
)
Used for connecting I/O of modules
with HE 10 connectors
1
to Telefast 2
fast wiring
2
connection and adaptation
interfaces. This cable
3
has 2 HE 10
connectors
4
and a rolled ribbon cable
with sheath with 0.08 mm
2
cross-
section wires.
Given the small cross-section of the
wires, it is recommended for use with
low current I/O only (100 mA maximum
per input or output).
TSX CDP 102 : 1 metre long
TSX CDP 202 : 2 metres long
TSX CDP 302 : 3 metres long
Connection cable, 22-gauge
(0.324 mm
2
)
Used for connecting the I/O of modules
with HE 10 connectors
1
to Telefast 2
fast wiring
2
connection and adaptation
interfaces. This cable
5
has 2 insulated
HE 10 connectors
6
and a cable for
carrying higher currents (500 mA
maximum).
TSX CDP 053 : 0.5 metres long
TSX CDP 103 : 1 metre long
TSX CDP 203 : 2 metres long
TSX CDP 303 : 3 metres long
TSX CDP 503 : 5 metres long
2
3
4
1
1
4
4
2
6
5
1
6
3
Characteristics :
pages 43520/5 to 43520/8
References :
pages 43520/9 and 43520/10
Connections :
pages 43520/11 to 43520/13