WESCHLER INSTRUMENTS

WESCHLER INSTRUMENTS
Hioki Chart Recorders
2 or 4 Channel Memory Recorder High-speed electronic recorders with powerful trigger functions. Use for low-speed/long-term continuous recording or capturing high-speed transients. Input: NEW
SPECIFICATIONS
2 analog, isolated + 8 logic (8807-01) 4 analog, isolated + 8 logic (8808-01) Range: 10 mV to 100 V/division, 13 ranges (10 division f.s.) Max. Voltage: 450V differential, 450V common mode Accuracy, BW: ±0.5%, DC to 50 kHz ± 3 dB Input: 1M, isolated BNC conncetor Trigger Source: Analog in, logic in, A-B, external, timer, manual, logical AND/OR Analog Trigger: Level, window, voltage drop, RMS level, waveform Functions Memory recorder, recorder, RMS & memory recorder (DC & 50/60 Hz only) Memory Time Axis: 200 µs to 5 minutes/division, 19 settings (1 division =80 samples) Memory Capacity: 256 k words/ch (using CH1) 128 k words/ch (using CH1 & CH2) Data storage: Type II PC card slot (for SRAM cards to 32 MB, flash ATA cards to 528 MB) Interfaces: RS-232C, PC card fax modem Display: 5.7-inch STN color LCD Printer Option: 112 mm (4.4 in) x 18 m (59.06 ft), thermal paper roll Other functions: DMM function (numeric display), Scaling, Parameter calculations, Cursor readout, etc. Power: AA batteries, AC adapter, rechargeable battery Dimensions: 8.0" x 6.7" x 2.1" (203x170x52mm) Supplied with AA batteries, shoulder belt & Waveform viewer software High Speed Memory Recorder
· Up to 20M samples/second · Expandable to 64 channels · Large internal memory · 10.4-inch high resolution color TFT display 8807
ORDERING INFORMATION
2 Channel Memory Recorder 4 Channel Memory Recorder Detachable Printer (requires AC adapter) Analog Input Leads (1 channel, 1.5m, alligator clips) Clamp-on Probe 10-500A, 40Hz-3kHz 100-240V AC Adapter (50/60 Hz) for 8807/8 Rechargeable Battery (3 hour use) Carrying Case RS-2332 Cable (1.5m) 8835 HI/8807-01 HI/8808-01 HI/8922 HI/9197 HI/9018-10 HI/9418-10 HI/9447 HI/9391 HI/9612 · 4/8 analog + 16 logic inputs · 6.4-inch color TFT liquid crystal display · 4M word memory · Built-in printer uses 110mm paper · RS-232, LAN & GPIB interfaces SPECIFICATIONS
10 mV to 50 V/div., 12 ranges (10 div. f.s.) with 8936 Analog Input Frequency: DC to 400 kHz ± 3 dB (with 8936 Analog Input) Memory Time Axis: 100 µs to 5 minutes/division, 20 settings (1 division =100 samples); external sampling (500 kS/s, minimum sampling period 2 µs) Measurement Memory recorder, Recorder, Functions: RMS recorder (50/60 Hz or DC only) Memory Capacity 4 M words x 1 channel to 500 k words x 8 channels Data Storage: FD drive, Type III PC card slot (SRAM/flash ATA/hard disk card) Other Functions: FFT, waveform parameter calculations, memory segmentation, cursor readouts, etc Power: 100-120 V AC (50/60 Hz), 10-28 V DC using the 9439 DC Power Adapter Dimensions: 11.2" x 8.7" x 5.2" (285x220x132mm) Supplied with Power cord, Recording paper(1 roll), Dust cover, Roll paper attachment(2), PC card protector, Wave viewer software. Order input modules (voltage, temperature, FFT, strain, F/V, charge), input leads, probes, data storage & interface separately. Measurement Range: Measurement Range: Input Options: 117
WESCHLER INSTRUMENTS · www.weschler.com · 800-903-9870 · fax: 800-903-9590 · info@weschler.com 4 or 8 Channel Memory Recorder 8860 SPECIFICATIONS
5 mV to 20 V/division, 12 ranges (20 divisions f.s.) 2ch, 12-bit, 20MS/s; 2ch, 16-bit, 2MS/s; 1ch Voltage/RMS, 12-bit, 1MS/s; 16ch Voltage/TC Trigger Types: Level, window, period, glitch, slope, logic pattern, voltage drop, external Memory Time Axis: 5ms to 5min/div, 25 settings or external sampling Memory Resolution: 100 points/div; zoom X2, X10 Memory Capacity: 32M word, expandable to 1G word Data Storage: FD drive, MO drive, HDD drive, Type II PC card slot (flash ATA) External Interfaces: USB1.1, Ethernet 10/100T, GPIB, HTTP, FTP, SVGA monitor Other Functions: FFT, waveform comparison, waveform calculations, clock, memory backup, sync out Power: 100-240 VAC, 140VA (300VA with A4 printer option) Dimensions: 13.0" x 10.75" x 7.25" (330x273x185mm) Specify up to four input modules, memory, data storage, interface & printer options. Test Leads and Carrying Case available separately. WESCHLER INSTRUMENTS
Fuji Strip Chart Recorders
· Inkjet printing technology without physical contact with the paper · Low-cost · Lightweight, durable, and trouble-free 100mm recorder · Available in one- or two-channel continuous trace · Continuous analog trending on the same axis · Prints periodic data, scale line, alarm condition, burnout, and parameter data · Manufactured in an ISO 9001 Facility ORDERING INFORMATION
To Order­Insert Number Code for Each Letter to Select Catalog Number. Order Example: PHE1-X-Y-32-5Y-OEV A - B - C - D - E - F A Recording Points PHE1 1 continuous recording point PHE2 2 continuous recording points Input Signal for Ch. 1 X B Thermocouple R R Thermocouple S S Thermocouple K K Thermocouple E E Thermocouple J J Thermocouple T T Thermocouple N N Thermocouple W W Thermocouple L L Thermocouple U U Thermocouple P PN Thermocouple H Pt100 RTD A DC 1-5V B DC 4-20mA with shunt resistor C DC 10-50mA with shunt resistor M DC ±50mV Q DC ±500mV V DC ±5V F DC ±50V Input Signal for Ch. 2 Y None X B Thermocouple R R Thermocouple S S Thermocouple K K Thermocouple E E Thermocouple J J Thermocouple T T Thermocouple N N Thermocouple W W Thermocouple L L Thermocouple U U Thermocouple P PN Thermocouple H Pt100 RTD A DC 1-5V B DC 4-20mA with shunt resistor C DC 10-50mA with shunt resistor M DC ±50mV Q DC ±500mV V DC ±5V F DC ±50V Power Supply 32 100V/120V AC, 50/60Hz 42 200V/240V AC, 50/60Hz Scale Range 5Y One channel 55 Two channels Alarm Output 0EV None 1EV 1-ch. recorder, 2-point/no external control AEV 1-ch. recorder, 2-point/with external control 2EV 2-ch. recorder, 4-point/no external control BEV 2-ch. recorder, 4-point/with external control B SPECIFICATIONS
Input Points: Input Signals: 1 or 2 continuous recording TC: B, R, S, K, E, J, T, N, W, L, U, PN RTD: Pt 100 DC Voltage: 50mV, 500mV, 5V, 50V range DC Current: 4 to 20mA, converted into voltage with 10 or 250 shunt resistor TC, RTD and DC Voltage: ±10V DC or less (50mV, 500mV range) DC Voltage Input: ±100V DC or less (5V, 50V range) Inkjet type, 3 colors 1 or 2 continuous Effective width: 100mm, Z-folding type, length­15.08m 2 sec. minimum (chart speed dependent) Indicating accuracy ±0.2% 10, 20, 24, 30, 50, 120, 200, 300, 400, 1000, 1200, 1500mm/hour, set from the keyboard 100 to 120 VAC or 200 to 240 VAC, 50/60Hz 5.67 x 5.67 x 6.89in. (144 x 144 x 175mm) Max. Allowable Input Voltage: Recording Method: Recording Points: Chart Paper: Recording Cycle: Recording Accuracy: Chart Speed: Power Supply: Dimensions (WxHxD): WESCHLER INSTRUMENTS · www.weschler.com · 800-903-9870 · fax: 800-903-9590 · info@weschler.com · Three-year warranty PHE C D E F 118 WESCHLER INSTRUMENTS
Amprobe Portable Strip Chart Recorders
Single Channel
· Single-Phase AC Volts or Amps · Expandable Voltage Scale for Improved Resolution (Scale Does Not Start at Zero) PAV-3 SPECIFICATIONS
Features AC Voltage ­ single phase 60Hz AC Current ­ single phase 60Hz Measurement Rate Chart paper speed Rolls paper back after recording Chart paper (30 foot) Chart paper (60 foot) PAV3X-T 95-130 / 190-260 V N/A 60s, 5s, 2.5s 1", 12" or 24" per hour yes 835X3A 835X3A-6 PAVA783-12 PAVA83-T 95-130 / 190-260 / 380-520 V 0-10 / 50 / 250 / 500 A 5 sec 60s, 5s, 2.5s 12" per hour 1", 12" or 24" per hour N/A Yes 835X3A-6 for Volts 850A for Ampers N/A 835X3A-6 for Volts 850A-6 for Amps Supplied with 120V Power Cord, Clamp-on Current Transducer and/or Voltage Input Leads OPTIONAL ACCESSORIES (for LAV and PAV models)
Part Number AB/A47L AB/CT50-1 AB/CT50-2 AB/A50-1 Line splitter (Energizer) 5000A Clamp-on Current Transformer (50 to 1) 3000A Clamp-on Current Transformer (50 to 1) 600A Clamp-on Current Transformer (10 to 1) ORDERING INFORMATION
AB/PAV3X-T AB/PAVA83-12 AB/PAVA83-T Single Channel ACV Recorder Single Channel ACV or ACA, 12"/HR Single Channel ACV or ACA, w take up Multi-Channel
· Single Phase or Three Phase · 3 Recording Speeds (12"/hr, 6"/hr, 1"/hr) · Rerolls Paper After Recording (-T Models) LAV21 RMS and LAV21 RMS ­T Number of phases recorded Single phase voltage simultaneously and current AC Voltage 0-150 / 300 / 600 V AC Current 0-15 / 60 / 150 / 300 A Chart paper, 30 foot roll 300SVA Chart paper, 60 foot roll 300SVA-6 ("-T" models only) (for LAV21 RMS-T only) Rolls paper back after recording LAV21 RMS-T only Features LAV3 RMS and LAV3 RMS ­T Three phase voltage (can record single phase) 0-150 / 300 / 600 V N/A 830AV600 830AV600-6 (for LAV3 RMS-T only) LAV3 RMS-T only LAA3 RMS and LAA3 RMS ­T Three phase current (can record single phase) N/A 0-15 / 60 / 150 / 300 A 300SVA 300SVA-6 (for LAA3 RMS-T only) LAA3 RMS-T only Supplied with 120V Power Cord, 300A Clamp-on Current Transducers and/or Voltage Leads ORDERING INFORMATION
AB/LAV21RMS AB/LAV21RMS-T AB/LAV3RMS AB/LAV3RMS-T AB/LAA3RMS AB/LAA3RMS-T Recorder, single phase ACV & ACA Recorder, single phase ACV & ACA, w/ take up Recorder, 1Ø or 3Ø, ACV Recorder, 1Ø or 3Ø, ACV, w/ take up Recorder 1Ø or 3Ø, ACA Recorder 1Ø or 3Ø, ACA, w/ take up 119
WESCHLER INSTRUMENTS · www.weschler.com · 800-903-9870 · fax: 800-903-9590 · info@weschler.com SPECIFICATIONS LAV-21 WESCHLER INSTRUMENTS
Hioki Strip Chart Recorders Partlow Chart Recorder
· 1 or 2 Trend Pen Versions
(optional) · Up to 2 Process or Limit Alarms for Each Pen · Simple Operation and Set-Up · Universal Inputs and Power Supply 8206-10 · NEMA 3 Standard (NEMA 4X Option) · Optional PC Configuration Port · RS-485 Communications Option · Two Year Warranty · AC or DC voltage to 500V · AC current to 1000A · 1 or 2 channels · 5 paper speeds · View input level on analog LCD display MRC5000 SPECIFICATIONS
Input Range: TC: J, K, T, R, S RTD: 100 Platinum, 0.00385 //°C Current DC: 0 to 20mA, 4 to 20mA Voltage DC: 0 to 25mV, 0 to 50mV, 10 to 50mV, 0 to 5V, 1 to 5V 10" User-configured: 8 hr, 12 hr, 24 hr, 48 hr, 7 day 0.5% of chart span reference accuracy 90 ­264VAC 50/60Hz. 18VA max. consumption 14" x 14" x 3.8" (355.6 x 355.6 x 96.5mm) 8205-10 SPECIFICATIONS
Input: DC /AC Voltage: AC Current: Sampling period: Bandwidth: Paper Speed: Accuracy: Power: Dimensions: Supplied Accessories: Voltage or current, 1 channel 0.1-500V f.s., 12 ranges 10-1000A f.s., 7 ranges (with optional clamp) 10ms 20Hz - 30kHz, ±3dB 20cm/minute to 2cm/hour, 5 ranges Voltage: ±2% f.s. Current: ±4% f.s. (using 9651 clamp) 100-240VAC (50/60Hz) or 9.5-14VDC 9.9"W x 4.8"H x 3.9"D 1 roll recording paper, carrying case, input leads Chart Size: Chart Rotation: Recording Accuracy: Power Requirements: Dimensions (WxHxD): ORDERING INFORMATION
To Order­Insert Number Code for Each Letter to Select Catalog Number. Order Example: PA/51 110211 A B C D E F G H 8206-10 SPECIFICATIONS
Input: AC Voltage: AC Current: Sampling period: Bandwidth: Paper Speed: Accuracy: Power: Dimensions: Supplied Accessories: Voltage and current, 2 channels alternate recording 100/200/500V extended scale, 3 ranges 10-1000A f.s., 7 ranges (with optional clamp) 10ms 30Hz to 30kHz, ±3dB 60cm/hour to 2cm/hour, 5 ranges Voltage: ±2% f.s. Current: ±4% f.s. (using 9651 clamp) 100-240VAC (50/60Hz) or 9.5-14VDC 9.9"W x 4.8"H x 3.9"D 1 roll recording paper, carrying case, input leads ORDERING INFORMATION
HK/8205-10 HK/8206-10 HK/9650 HK/9651 HK/9668 HK/9235 HK/9236-01 One Channel Micro HiCorder Two Channel Micro HiCorder Clamp-on Sensor, 100A f.s., 40Hz-1kHz, 3m length Clamp-on Sensor, 500A f.s., 40Hz-1kHz, 3m length Clamp-on Sensor, 1000A f.s., 40Hz-1kHz, 3m length Recording paper (15m, 10 rolls) Recording paper, Climate-resistant (15m, 10 rolls) A Pen 1 PA/51 Recorder only PA/52 Recording Controller B Pen 2 0 None 1 Recorder only C Pen 1 Outputs 0 None 1 One Relay D Pen 2 Outputs 0 None 1 One Relay E Digital Communications 0 None 1 Configurator Port F Case 1 Standard-NEMA3 2 Door Lock G Voltage 1 Standard (90­264V AC) 3 Standard, with 24V DC Transmitter Power Supply H Option Suffix Blank None PA/54 High/Low Limit 2 4 2 Recording Controller High/Low Limit Two Relays 2 Two Relays 2 3 3 RS-485 Com (Modbus RTU) Configurator Port & RS-485 Com NEMA 4X 5 7 Standard, with CE Approval Standard, with CE and Transmitter Power Supply Alarms and communications connectivity option One hundred 0-100°F, 24-hour charts are provided with each instrument. AA 120
WESCHLER INSTRUMENTS · www.weschler.com · 800-903-9870 · fax: 800-903-9590 · info@weschler.com WESCHLER INSTRUMENTS
Hoyt Dataloggers
· Miniature, standalone modules · Battery powered · Non-volatile solid state memory · Programmable start time · PC setup & data retrieval NEW Hioki Data Loggers
· Miniature size · 16,000 or 32,000 reading storage · Data is retained even when the batteries are dead · Power saving function Volt101
QuadTemp
Model Temperature HK/3632-20 HK/3633-20 Range -20 to 70.0°C -40 to 180.0°C 16k 16k Memory* Feature Waterproof with built-in sensor External/internal sensor, waterproof Alternately record on two channels Maximum sample interval is 12 hours. Operating temperature is -40 to +80°C,