WESCHLER INSTRUMENTS
WESCHLER INSTRUMENTS
Hioki Chart Recorders
2 or 4 Channel Memory Recorder High-speed electronic recorders with powerful trigger functions. Use for low-speed/long-term continuous recording or capturing high-speed transients. Input:
NEW
SPECIFICATIONS
2 analog, isolated + 8 logic (8807-01) 4 analog, isolated + 8 logic (8808-01) Range: 10 mV to 100 V/division, 13 ranges (10 division f.s.) Max. Voltage: 450V differential, 450V common mode Accuracy, BW: ±0.5%, DC to 50 kHz ± 3 dB Input: 1M, isolated BNC conncetor Trigger Source: Analog in, logic in, A-B, external, timer, manual, logical AND/OR Analog Trigger: Level, window, voltage drop, RMS level, waveform Functions Memory recorder, recorder, RMS & memory recorder (DC & 50/60 Hz only) Memory Time Axis: 200 µs to 5 minutes/division, 19 settings (1 division =80 samples) Memory Capacity: 256 k words/ch (using CH1) 128 k words/ch (using CH1 & CH2) Data storage: Type II PC card slot (for SRAM cards to 32 MB, flash ATA cards to 528 MB) Interfaces: RS-232C, PC card fax modem Display: 5.7-inch STN color LCD Printer Option: 112 mm (4.4 in) x 18 m (59.06 ft), thermal paper roll Other functions: DMM function (numeric display), Scaling, Parameter calculations, Cursor readout, etc. Power: AA batteries, AC adapter, rechargeable battery Dimensions: 8.0" x 6.7" x 2.1" (203x170x52mm) Supplied with AA batteries, shoulder belt & Waveform viewer software High Speed Memory Recorder
· Up to 20M samples/second · Expandable to 64 channels · Large internal memory · 10.4-inch high resolution color TFT display
8807
ORDERING INFORMATION
2 Channel Memory Recorder 4 Channel Memory Recorder Detachable Printer (requires AC adapter) Analog Input Leads (1 channel, 1.5m, alligator clips) Clamp-on Probe 10-500A, 40Hz-3kHz 100-240V AC Adapter (50/60 Hz) for 8807/8 Rechargeable Battery (3 hour use) Carrying Case RS-2332 Cable (1.5m) 8835
HI/8807-01 HI/8808-01 HI/8922 HI/9197 HI/9018-10 HI/9418-10 HI/9447 HI/9391 HI/9612
· 4/8 analog + 16 logic inputs · 6.4-inch color TFT liquid crystal display · 4M word memory · Built-in printer uses 110mm paper · RS-232, LAN & GPIB interfaces
SPECIFICATIONS
10 mV to 50 V/div., 12 ranges (10 div. f.s.) with 8936 Analog Input Frequency: DC to 400 kHz ± 3 dB (with 8936 Analog Input) Memory Time Axis: 100 µs to 5 minutes/division, 20 settings (1 division =100 samples); external sampling (500 kS/s, minimum sampling period 2 µs) Measurement Memory recorder, Recorder, Functions: RMS recorder (50/60 Hz or DC only) Memory Capacity 4 M words x 1 channel to 500 k words x 8 channels Data Storage: FD drive, Type III PC card slot (SRAM/flash ATA/hard disk card) Other Functions: FFT, waveform parameter calculations, memory segmentation, cursor readouts, etc Power: 100-120 V AC (50/60 Hz), 10-28 V DC using the 9439 DC Power Adapter Dimensions: 11.2" x 8.7" x 5.2" (285x220x132mm) Supplied with Power cord, Recording paper(1 roll), Dust cover, Roll paper attachment(2), PC card protector, Wave viewer software. Order input modules (voltage, temperature, FFT, strain, F/V, charge), input leads, probes, data storage & interface separately. Measurement Range: Measurement Range: Input Options:
117
WESCHLER INSTRUMENTS · www.weschler.com · 800-903-9870 · fax: 800-903-9590 · info@weschler.com
4 or 8 Channel Memory Recorder
8860
SPECIFICATIONS
5 mV to 20 V/division, 12 ranges (20 divisions f.s.) 2ch, 12-bit, 20MS/s; 2ch, 16-bit, 2MS/s; 1ch Voltage/RMS, 12-bit, 1MS/s; 16ch Voltage/TC Trigger Types: Level, window, period, glitch, slope, logic pattern, voltage drop, external Memory Time Axis: 5ms to 5min/div, 25 settings or external sampling Memory Resolution: 100 points/div; zoom X2, X10 Memory Capacity: 32M word, expandable to 1G word Data Storage: FD drive, MO drive, HDD drive, Type II PC card slot (flash ATA) External Interfaces: USB1.1, Ethernet 10/100T, GPIB, HTTP, FTP, SVGA monitor Other Functions: FFT, waveform comparison, waveform calculations, clock, memory backup, sync out Power: 100-240 VAC, 140VA (300VA with A4 printer option) Dimensions: 13.0" x 10.75" x 7.25" (330x273x185mm) Specify up to four input modules, memory, data storage, interface & printer options. Test Leads and Carrying Case available separately.
WESCHLER INSTRUMENTS
Fuji Strip Chart Recorders
· Inkjet printing technology without physical contact with the paper · Low-cost · Lightweight, durable, and trouble-free 100mm recorder · Available in one- or two-channel continuous trace · Continuous analog trending on the same axis · Prints periodic data, scale line, alarm condition, burnout, and parameter data · Manufactured in an ISO 9001 Facility
ORDERING INFORMATION
To OrderInsert Number Code for Each Letter to Select Catalog Number. Order Example: PHE1-X-Y-32-5Y-OEV A - B - C - D - E - F A Recording Points PHE1 1 continuous recording point PHE2 2 continuous recording points Input Signal for Ch. 1 X B Thermocouple R R Thermocouple S S Thermocouple K K Thermocouple E E Thermocouple J J Thermocouple T T Thermocouple N N Thermocouple W W Thermocouple L L Thermocouple U U Thermocouple P PN Thermocouple H Pt100 RTD A DC 1-5V B DC 4-20mA with shunt resistor C DC 10-50mA with shunt resistor M DC ±50mV Q DC ±500mV V DC ±5V F DC ±50V Input Signal for Ch. 2 Y None X B Thermocouple R R Thermocouple S S Thermocouple K K Thermocouple E E Thermocouple J J Thermocouple T T Thermocouple N N Thermocouple W W Thermocouple L L Thermocouple U U Thermocouple P PN Thermocouple H Pt100 RTD A DC 1-5V B DC 4-20mA with shunt resistor C DC 10-50mA with shunt resistor M DC ±50mV Q DC ±500mV V DC ±5V F DC ±50V Power Supply 32 100V/120V AC, 50/60Hz 42 200V/240V AC, 50/60Hz Scale Range 5Y One channel 55 Two channels Alarm Output 0EV None 1EV 1-ch. recorder, 2-point/no external control AEV 1-ch. recorder, 2-point/with external control 2EV 2-ch. recorder, 4-point/no external control BEV 2-ch. recorder, 4-point/with external control
B
SPECIFICATIONS
Input Points: Input Signals: 1 or 2 continuous recording TC: B, R, S, K, E, J, T, N, W, L, U, PN RTD: Pt 100 DC Voltage: 50mV, 500mV, 5V, 50V range DC Current: 4 to 20mA, converted into voltage with 10 or 250 shunt resistor TC, RTD and DC Voltage: ±10V DC or less (50mV, 500mV range) DC Voltage Input: ±100V DC or less (5V, 50V range) Inkjet type, 3 colors 1 or 2 continuous Effective width: 100mm, Z-folding type, length15.08m 2 sec. minimum (chart speed dependent) Indicating accuracy ±0.2% 10, 20, 24, 30, 50, 120, 200, 300, 400, 1000, 1200, 1500mm/hour, set from the keyboard 100 to 120 VAC or 200 to 240 VAC, 50/60Hz 5.67 x 5.67 x 6.89in. (144 x 144 x 175mm)
Max. Allowable Input Voltage:
Recording Method: Recording Points: Chart Paper: Recording Cycle: Recording Accuracy: Chart Speed: Power Supply: Dimensions (WxHxD):
WESCHLER INSTRUMENTS · www.weschler.com · 800-903-9870 · fax: 800-903-9590 · info@weschler.com
· Three-year warranty
PHE
C
D
E
F
118
WESCHLER INSTRUMENTS
Amprobe Portable Strip Chart Recorders
Single Channel
· Single-Phase AC Volts or Amps · Expandable Voltage Scale for Improved Resolution (Scale Does Not Start at Zero) PAV-3
SPECIFICATIONS
Features AC Voltage single phase 60Hz AC Current single phase 60Hz Measurement Rate Chart paper speed Rolls paper back after recording Chart paper (30 foot) Chart paper (60 foot) PAV3X-T 95-130 / 190-260 V N/A 60s, 5s, 2.5s 1", 12" or 24" per hour yes 835X3A 835X3A-6 PAVA783-12 PAVA83-T 95-130 / 190-260 / 380-520 V 0-10 / 50 / 250 / 500 A 5 sec 60s, 5s, 2.5s 12" per hour 1", 12" or 24" per hour N/A Yes 835X3A-6 for Volts 850A for Ampers N/A 835X3A-6 for Volts 850A-6 for Amps
Supplied with 120V Power Cord, Clamp-on Current Transducer and/or Voltage Input Leads
OPTIONAL ACCESSORIES (for LAV and PAV models)
Part Number AB/A47L AB/CT50-1 AB/CT50-2 AB/A50-1 Line splitter (Energizer) 5000A Clamp-on Current Transformer (50 to 1) 3000A Clamp-on Current Transformer (50 to 1) 600A Clamp-on Current Transformer (10 to 1)
ORDERING INFORMATION
AB/PAV3X-T AB/PAVA83-12 AB/PAVA83-T Single Channel ACV Recorder Single Channel ACV or ACA, 12"/HR Single Channel ACV or ACA, w take up
Multi-Channel
· Single Phase or Three Phase · 3 Recording Speeds (12"/hr, 6"/hr, 1"/hr) · Rerolls Paper After Recording (-T Models)
LAV21 RMS and LAV21 RMS T Number of phases recorded Single phase voltage simultaneously and current AC Voltage 0-150 / 300 / 600 V AC Current 0-15 / 60 / 150 / 300 A Chart paper, 30 foot roll 300SVA Chart paper, 60 foot roll 300SVA-6 ("-T" models only) (for LAV21 RMS-T only) Rolls paper back after recording LAV21 RMS-T only
Features
LAV3 RMS and LAV3 RMS T Three phase voltage (can record single phase) 0-150 / 300 / 600 V N/A 830AV600 830AV600-6 (for LAV3 RMS-T only) LAV3 RMS-T only
LAA3 RMS and LAA3 RMS T Three phase current (can record single phase) N/A 0-15 / 60 / 150 / 300 A 300SVA 300SVA-6 (for LAA3 RMS-T only) LAA3 RMS-T only
Supplied with 120V Power Cord, 300A Clamp-on Current Transducers and/or Voltage Leads
ORDERING INFORMATION
AB/LAV21RMS AB/LAV21RMS-T AB/LAV3RMS AB/LAV3RMS-T AB/LAA3RMS AB/LAA3RMS-T Recorder, single phase ACV & ACA Recorder, single phase ACV & ACA, w/ take up Recorder, 1Ø or 3Ø, ACV Recorder, 1Ø or 3Ø, ACV, w/ take up Recorder 1Ø or 3Ø, ACA Recorder 1Ø or 3Ø, ACA, w/ take up
119
WESCHLER INSTRUMENTS · www.weschler.com · 800-903-9870 · fax: 800-903-9590 · info@weschler.com
SPECIFICATIONS
LAV-21
WESCHLER INSTRUMENTS
Hioki Strip Chart Recorders Partlow Chart Recorder
· 1 or 2 Trend Pen Versions
(optional)
· Up to 2 Process or Limit Alarms for Each Pen · Simple Operation and Set-Up · Universal Inputs and Power Supply
8206-10
· NEMA 3 Standard (NEMA 4X Option) · Optional PC Configuration Port · RS-485 Communications Option · Two Year Warranty
· AC or DC voltage to 500V · AC current to 1000A · 1 or 2 channels · 5 paper speeds · View input level on analog LCD display
MRC5000
SPECIFICATIONS
Input Range: TC: J, K, T, R, S RTD: 100 Platinum, 0.00385 //°C Current DC: 0 to 20mA, 4 to 20mA Voltage DC: 0 to 25mV, 0 to 50mV, 10 to 50mV, 0 to 5V, 1 to 5V 10" User-configured: 8 hr, 12 hr, 24 hr, 48 hr, 7 day 0.5% of chart span reference accuracy 90 264VAC 50/60Hz. 18VA max. consumption 14" x 14" x 3.8" (355.6 x 355.6 x 96.5mm)
8205-10 SPECIFICATIONS
Input: DC /AC Voltage: AC Current: Sampling period: Bandwidth: Paper Speed: Accuracy: Power: Dimensions: Supplied Accessories: Voltage or current, 1 channel 0.1-500V f.s., 12 ranges 10-1000A f.s., 7 ranges (with optional clamp) 10ms 20Hz - 30kHz, ±3dB 20cm/minute to 2cm/hour, 5 ranges Voltage: ±2% f.s. Current: ±4% f.s. (using 9651 clamp) 100-240VAC (50/60Hz) or 9.5-14VDC 9.9"W x 4.8"H x 3.9"D 1 roll recording paper, carrying case, input leads
Chart Size: Chart Rotation: Recording Accuracy: Power Requirements: Dimensions (WxHxD):
ORDERING INFORMATION
To OrderInsert Number Code for Each Letter to Select Catalog Number. Order Example: PA/51 110211 A B C D E F G H
8206-10 SPECIFICATIONS
Input: AC Voltage: AC Current: Sampling period: Bandwidth: Paper Speed: Accuracy: Power: Dimensions: Supplied Accessories: Voltage and current, 2 channels alternate recording 100/200/500V extended scale, 3 ranges 10-1000A f.s., 7 ranges (with optional clamp) 10ms 30Hz to 30kHz, ±3dB 60cm/hour to 2cm/hour, 5 ranges Voltage: ±2% f.s. Current: ±4% f.s. (using 9651 clamp) 100-240VAC (50/60Hz) or 9.5-14VDC 9.9"W x 4.8"H x 3.9"D 1 roll recording paper, carrying case, input leads
ORDERING INFORMATION
HK/8205-10 HK/8206-10 HK/9650 HK/9651 HK/9668 HK/9235 HK/9236-01 One Channel Micro HiCorder Two Channel Micro HiCorder Clamp-on Sensor, 100A f.s., 40Hz-1kHz, 3m length Clamp-on Sensor, 500A f.s., 40Hz-1kHz, 3m length Clamp-on Sensor, 1000A f.s., 40Hz-1kHz, 3m length Recording paper (15m, 10 rolls) Recording paper, Climate-resistant (15m, 10 rolls)
A Pen 1 PA/51 Recorder only PA/52 Recording Controller B Pen 2 0 None 1 Recorder only C Pen 1 Outputs 0 None 1 One Relay D Pen 2 Outputs 0 None 1 One Relay E Digital Communications 0 None 1 Configurator Port F Case 1 Standard-NEMA3 2 Door Lock G Voltage 1 Standard (90264V AC) 3 Standard, with 24V DC Transmitter Power Supply H Option Suffix Blank None
PA/54
High/Low Limit
2 4 2
Recording Controller High/Low Limit Two Relays
2
Two Relays
2 3 3
RS-485 Com (Modbus RTU) Configurator Port & RS-485 Com NEMA 4X
5 7
Standard, with CE Approval Standard, with CE and Transmitter Power Supply
Alarms and communications connectivity option One hundred 0-100°F, 24-hour charts are provided with each instrument.
AA
120
WESCHLER INSTRUMENTS · www.weschler.com · 800-903-9870 · fax: 800-903-9590 · info@weschler.com
WESCHLER INSTRUMENTS
Hoyt Dataloggers
· Miniature, standalone modules · Battery powered · Non-volatile solid state memory · Programmable start time · PC setup & data retrieval
NEW
Hioki Data Loggers
· Miniature size · 16,000 or 32,000 reading storage · Data is retained even when the batteries are dead · Power saving function
Volt101
QuadTemp
Model Temperature HK/3632-20 HK/3633-20 Range -20 to 70.0°C -40 to 180.0°C 16k 16k
Memory* Feature Waterproof with built-in sensor External/internal sensor, waterproof Alternately record on two channels
Maximum sample interval is 12 hours. Operating temperature is -40 to +80°C,