INSTRUMENT TRANSFORMERS
h the authors of this page or responsible for its content.
INSTRUMENT TRANSFORMERS
16
419
LOW VOLTAGE CURRENT TRANSFORMERS
600 Volt Class - Indoor Type
420
LOW VOLTAGE POTENTIAL TRANSFORMERS
600 Volt Class - Indoor Type
422
BUSHING CURRENT TRANSFORMERS
600 Volt Class
425
MEDIUM VOLTAGE CURRENT & POTENTIAL TRANSFORMERS
5KV to 38kV - Indoor type
426
CONTROL POWER TRANSFORMERS
5KV to 38kV - Indoor type
427
CURRENT TRANSDUCERS
600 Volt Class
428
INSTRUMENT TRANSFORMERS
CURRENT TRANSFORMERS
16
420
www.GEMultilin.com
Applications
Energy management
Load surveys
Sub metering
Features
Window sizes from 0.75 x 0.75 to 12 x 30 inches
Ratios from 100:5A to 10,000:5A
Voltage output available
Weather proof model available
UL Recognized and CSA Approved
Applications
Three phase metering and motor overload protection
Features
Over 50 models available
Saves space and reduces installation time
Zero sequence core in the same package available for most models
Ratios from 50:5A to and up
UL Recognized and CSA Approved
Applications
Designed for use in the secondary of main current transformers to
change the ratio for metering or relaying applications
Features
Several models available
Wound primary up to 50A
IEEE or IEC metering and relay class
Summation CTs up to six secondaries
UL Recognized and CSA Approved
Split Core Current Transformers
Auxiliary Current Transformers
Three Phase Current Transformers
Applications
Designed for specific mount applications in medium voltage switchgear
Features
Wide range of window sizes
Ratios 50:5A to 6000:5A
1 Amp secondaries are available
Multi ratios model available
Designed to meet IEEE C57. 13
UL listed and CSA Approved
Applications
For use with ammeters in panelboards, control panels and
engine generators
Features
Wide range of window sizes
Ratios 50:5A to 2000:5A
1 Amp secondaries are available
Supplied with leads or terminals
Integral feet or mounting brackets available
UL Listed and CSA Approved
Applications
For metering and relaying applications in low voltage
switchboards, switchgear and motor control
Features
Wide range of window sizes
Ratios 50:5A to 6000:5A
1 Amp secondaries are available
Supplied with leads or terminals
Multi ratios model available
Designed to meet IEEE C57. 13 or IEC 60044-1
UL listed and CSA Approved
Current Transformers
Current Transformers
Current Transformers
CURRENT TRANSFORMERS
16
421
www.GEMultilin.com
LOW VOLTAGE INSTRUMENT TRANSFORMERS
16
422
www.GEMultilin.com
Applications
To sense zero sequence ground fault currents
Features
Window sizes up to 30x 10 inches are available
Ratios 50:5A and up
Special ratios and physical sizes built to customer specifications
UL Recognized and CSA Approved
Applications
For ammeters, wattmeters, and cross current compensation
applications
Features
Wide range of window sizes
Ratios 50:5A to 6000:5A
1 Amp secondaries are available
Supplied with leads or terminals
Integral feet or mounting brackets available
UL Listed and CSA Approved
Applications
Designed to match the ground fault input of GE Multilin motor
protection relays
Features
Window sizes 3.75 , 5.75 or 8.13
Ratio 50:0.025A 60 Hz
IEC versions also available
UL and CUL recognized
Current Transformers
Ground Fault Sensors
Ground Fault Sensors Type HGF
LOW VOLTAGE INSTRUMENT TRANSFORMERS
16
423
www.GEMultilin.com
LOW VOLTAGE INSTRUMENT TRANSFORMERS
Applications
Designed for operation of meters and instruments
Utility metering large window
Features
Designed for outdoor service
Compression type terminals
Rations from 200:5A to 4000:5A
Dual ratio models available
Engraved aluminum name plate
Meet ANSI C12 size and mounting
Applications
Designed for operation of meters and instruments
Utility metering small window
Features
Designed for outdoor service
Encapsulated in cast polyurethane resin
Compression type terminals
Ratios from 100:5A to 800:5A
Dual ratio models available
Engraved aluminum name plate
Meet ANSI C12 size and mounting
Applications
Designed for operation of meters and instruments
Utility metering
Mounts directly on busbars or padmount transformer spade
Features
Window sizes 3.46 x 4.16
Ratios 200:5 to 4000:5
Meet ANSI C12 size and mounting
Current Transformers
Current Transformers
Current Transformers
LOW VOLTAGE INSTRUMENT TRANSFORMERS
16
424
www.GEMultilin.com
Applications
For single phase voltage measurement in AC power system
Features
Resin cast moulded plastic cases
Integral fuses available on some models
Designed to meet IEEE C57.13
50Hz design available
UL Recognized and CSA Approved
Applications
For three phase voltage measure in AC power system
Features
Resin cast moulded plastic cases
Integral fuses available on some models
Designed to meet IEEE C57.13
50Hz design available
UL Recognized and CSA Approved
Applications
Designed for outdoor service, generating meter instruments
and relays
Utility metering
Features
Housed in a resin filled plastic case
Compression type terminals
50Hz design available
Transparent plastic terminals cover
Engraved aluminum nameplate
Designed to meet IEEE C57.13
Voltage Transformers
Voltage Transformers
JVA Voltage Transformers
BUSHING CURRENT TRANSFORMERS
16
425
www.GEMultilin.com
Applications
For use over bushings of power transformers and dead
tank circuit breakers
For metering and relaying applications
Features
Indoor or outdoor service
600 class to IEEE C57.13 or IEC 60044-1
Ratios 600: 50:5 to 25000:5
Single and multi ratios available
Optional ground shield available
Applications
Designed to customers specifications for metering and
relaying applications
High voltage circuit breakers and power transformers
Features
600 class to IEEE C57.13 - 1993
Single and multi ratios designs available
Leads or terminals available
Designs for use in oil are available
Applications
Designed for mounting and stacking over the bushings of
large generators
For metering and relaying applications
Features
Ratios up to 40,000:5A
1 Amp secondaries and IEC design available
600V class 50 or 60Hz
Shield winding available
Cast Resin Unit
Taped Unit
Board Mounted Unit
MEDIUM VOLTAGE INSTRUMENT TRANSFORMERS
16
426
www.GEMultilin.com
Applications
Indoor voltage transformer for metering and relaying applications in
AC power systems
Features
Vacuum cast polyurethane resin
Designed to meet IEEE C57.13
5kV to 38kV with BIL rating up to 200kV
UL Recognized and CSA Approved
Applications
Indoor current transformer for metering and relaying applications in
AC power systems
Features
Vacuum cast polyurethane resin
Designed to meet IEEE C57.13
15kV with BIL rating up to 110kV
UL Recognized and CSA Approved
Applications
Indoor current transformer for metering and relaying applications in AC
power systems.
Features
Vacuum cast using polyurethane resin
Designed to meet IEEE C57.13
5kV to 8.7kV with BIL rating up to 60kV
UL Recognized and CSA Approved
Voltage Transformers
Current Transformers
Current Transformers
CONTROL POWER TRANSFORMERS
16
427
www.GEMultilin.com
Applications
To provide control power in medium voltage switchgear
Features
Vacuum cast primary coil using epoxy resin
Single phase rating from 5 kVA to 15 kVA
Voltage rating 5 to 15 kV and BIL rating to 95 kV BIL
Applications
To provide control power in medium voltage switchgear
Generator neutral grounding transformer
Features
Vacuum cast primary and secondary coils using epoxy resin
Single phase rating from 25 kVA to 75 kVA
Voltage rating 5 to 38kV and BIL rating to 150 kV BIL
Applications
To provide control power in medium voltage switchgear
Features
Vacuum cast using epoxy resin
Three phase rating from 15 kVA to 150 kVA
Voltage rating 5 to 38kV and BIL rating to 150 kV BIL
Horizontal and vertical mounting available in some models
Single Phase Cast Coil transformers
Single Phase Cast Coil transformers
Three Phase Cast Coil transformers
CURRENT TRANSDUCERS
16
428
www.GEMultilin.com
Applications
Process control
Industrial measurement
Features
Models available for 5 to 600 primary AC current
Output Options: 0-5 Vdc, 0-10 Vdc, and 4-20 mA
Self powered, two wire option
UL recognized
Current Transducers