INSTRUMENT TRANSFORMERS 16
419
LOW VOLTAGE CURRENT TRANSFORMERS
600 Volt Class - Indoor Type
420
LOW VOLTAGE POTENTIAL TRANSFORMERS
600 Volt Class - Indoor Type
422
BUSHING CURRENT TRANSFORMERS
600 Volt Class
425
MEDIUM VOLTAGE CURRENT & POTENTIAL TRANSFORMERS
5KV to 38kV - Indoor type
426
CONTROL POWER TRANSFORMERS
5KV to 38kV - Indoor type
427
CURRENT TRANSDUCERS
600 Volt Class
428
INSTRUMENT TRANSFORMERS CURRENT TRANSFORMERS
16
420
www.GEMultilin.com
Applications Energy management Load surveys Sub metering
Features Window sizes from 0.75 x 0.75 to 12 x 30 inches Ratios from 100:5A to 10,000:5A Voltage output available Weather proof model available UL Recognized and CSA Approved
Applications Three phase metering and motor overload protection
Features Over 50 models available Saves space and reduces installation time Zero sequence core in the same package available for most models Ratios from 50:5A to and up UL Recognized and CSA Approved
Applications Designed for use in the secondary of main current transformers to
change the ratio for metering or relaying applications
Features Several models available Wound primary up to 50A IEEE or IEC metering and relay class Summation CTs up to six secondaries UL Recognized and CSA Approved
Split Core Current Transformers
Auxiliary Current Transformers
Three Phase Current Transformers Applications Designed for specific mount applications in medium voltage switchgear
Features Wide range of window sizes Ratios 50:5A to 6000:5A 1 Amp secondaries are available Multi ratios model available Designed to meet IEEE C57. 13 UL listed and CSA Approved
Applications For use with ammeters in panelboards, control panels and
engine generators
Features Wide range of window sizes Ratios 50:5A to 2000:5A 1 Amp secondaries are available Supplied with leads or terminals Integral feet or mounting brackets available UL Listed and CSA Approved
Applications For metering and relaying applications in low voltage
switchboards, switchgear and motor control
Features Wide range of window sizes Ratios 50:5A to 6000:5A 1 Amp secondaries are available Supplied with leads or terminals Multi ratios model available Designed to meet IEEE C57. 13 or IEC 60044-1 UL listed and CSA Approved
Current Transformers
Current Transformers
Current Transformers
CURRENT TRANSFORMERS
16
421
www.GEMultilin.com LOW VOLTAGE INSTRUMENT TRANSFORMERS
16
422
www.GEMultilin.com
Applications To sense zero sequence ground fault currents
Features Window sizes up to 30x 10 inches are available Ratios 50:5A and up Special ratios and physical sizes built to customer specifications UL Recognized and CSA Approved
Applications For ammeters, wattmeters, and cross current compensation
applications
Features Wide range of window sizes Ratios 50:5A to 6000:5A 1 Amp secondaries are available Supplied with leads or terminals Integral feet or mounting brackets available UL Listed and CSA Approved
Applications Designed to match the ground fault input of GE Multilin motor
protection relays
Features Window sizes 3.75 , 5.75 or 8.13 Ratio 50:0.025A 60 Hz IEC versions also available UL and CUL recognized
Current Transformers
Ground Fault Sensors
Ground Fault Sensors Type HGF LOW VOLTAGE INSTRUMENT TRANSFORMERS
16
423
www.GEMultilin.com
LOW VOLTAGE INSTRUMENT TRANSFORMERS
Applications Designed for operation of meters and instruments Utility metering large window
Features Designed for outdoor service Compression type terminals Rations from 200:5A to 4000:5A Dual ratio models available Engraved aluminum name plate Meet ANSI C12 size and mounting
Applications Designed for operation of meters and instruments Utility metering small window
Features Designed for outdoor service Encapsulated in cast polyurethane resin Compression type terminals Ratios from 100:5A to 800:5A Dual ratio models available Engraved aluminum name plate Meet ANSI C12 size and mounting
Applications Designed for operation of meters and instruments Utility metering Mounts directly on busbars or padmount transformer spade
Features Window sizes 3.46 x 4.16 Ratios 200:5 to 4000:5 Meet ANSI C12 size and mounting
Current Transformers
Current Transformers
Current Transformers LOW VOLTAGE INSTRUMENT TRANSFORMERS
16
424
www.GEMultilin.com
Applications For single phase voltage measurement in AC power system
Features Resin cast moulded plastic cases Integral fuses available on some models Designed to meet IEEE C57.13 50Hz design available UL Recognized and CSA Approved
Applications For three phase voltage measure in AC power system
Features Resin cast moulded plastic cases Integral fuses available on some models Designed to meet IEEE C57.13 50Hz design available UL Recognized and CSA Approved
Applications Designed for outdoor service, generating meter instruments
and relays Utility metering
Features Housed in a resin filled plastic case Compression type terminals 50Hz design available Transparent plastic terminals cover Engraved aluminum nameplate Designed to meet IEEE C57.13
Voltage Transformers
Voltage Transformers
JVA Voltage Transformers BUSHING CURRENT TRANSFORMERS
16
425
www.GEMultilin.com
Applications For use over bushings of power transformers and dead
tank circuit breakers For metering and relaying applications
Features Indoor or outdoor service 600 class to IEEE C57.13 or IEC 60044-1 Ratios 600: 50:5 to 25000:5 Single and multi ratios available Optional ground shield available
Applications Designed to customers specifications for metering and
relaying applications High voltage circuit breakers and power transformers
Features 600 class to IEEE C57.13 - 1993 Single and multi ratios designs available Leads or terminals available Designs for use in oil are available
Applications Designed for mounting and stacking over the bushings of
large generators For metering and relaying applications
Features Ratios up to 40,000:5A 1 Amp secondaries and IEC design available 600V class 50 or 60Hz Shield winding available
Cast Resin Unit
Taped Unit
Board Mounted Unit MEDIUM VOLTAGE INSTRUMENT TRANSFORMERS
16
426
www.GEMultilin.com
Applications Indoor voltage transformer for metering and relaying applications in
AC power systems
Features Vacuum cast polyurethane resin Designed to meet IEEE C57.13 5kV to 38kV with BIL rating up to 200kV UL Recognized and CSA Approved
Applications Indoor current transformer for metering and relaying applications in
AC power systems
Features Vacuum cast polyurethane resin Designed to meet IEEE C57.13 15kV with BIL rating up to 110kV UL Recognized and CSA Approved
Applications Indoor current transformer for metering and relaying applications in AC
power systems.
Features Vacuum cast using polyurethane resin Designed to meet IEEE C57.13 5kV to 8.7kV with BIL rating up to 60kV UL Recognized and CSA Approved
Voltage Transformers
Current Transformers
Current Transformers CONTROL POWER TRANSFORMERS
16
427
www.GEMultilin.com
Applications To provide control power in medium voltage switchgear
Features Vacuum cast primary coil using epoxy resin Single phase rating from 5 kVA to 15 kVA Voltage rating 5 to 15 kV and BIL rating to 95 kV BIL
Applications To provide control power in medium voltage switchgear Generator neutral grounding transformer
Features Vacuum cast primary and secondary coils using epoxy resin Single phase rating from 25 kVA to 75 kVA Voltage rating 5 to 38kV and BIL rating to 150 kV BIL
Applications To provide control power in medium voltage switchgear
Features Vacuum cast using epoxy resin Three phase rating from 15 kVA to 150 kVA Voltage rating 5 to 38kV and BIL rating to 150 kV BIL Horizontal and vertical mounting available in some models
Single Phase Cast Coil transformers
Single Phase Cast Coil transformers
Three Phase Cast Coil transformers CURRENT TRANSDUCERS
16
428
www.GEMultilin.com
Applications Process control Industrial measurement
Features Models available for 5 to 600 primary AC current Output Options: 0-5 Vdc, 0-10 Vdc, and 4-20 mA Self powered, two wire option UL recognized
Current Transducers