Intelligent metering and control devices
ed with the authors of this page or responsible for its content.
Intelligent metering and control devices
Applications Summary
Power Quality Analysis
Discover the sources of power quality events,
harmonics, and voltage sags/swells. Analyze
problems and avoid repeat interruptions.
Cost Allocation & Billing
Determine cost centers, identify opportunities for
demand control and check energy consumption
patterns. Use comprehensive multi-year
scheduling and time-of-use activity profiles.
Demand & Power Factor Control
Avoid penalties with automated load shedding,
scheduling, peak shaving or capacitor bank
control.
Load Studies & Circuit Optimization
Determine the capacity of your electric network
and run at peak efficiency. Perform load trending.
Equipment Monitoring & Control
Improve process yields and extend equipment life.
Meter all your utilities including gas, steam, water
and more.
Preventative Maintenance
Set up alarms to warn of pending problems. Log
events and alarms for all critical conditions.
Features Summary
Measurements
Revenue certified
Instantaneous voltage, current, frequency,
power factor
Energy: bi-directional, absolute, net.
Demand: sliding window, predicted, thermal
Harmonics: individual & total harmonic
distortion up to the 63rd
Sag/swell recording
Communications
Optional built-in modem with ModemGate
to allow modem access for 31 other devices
Optional 10Base-T or 10Base-FL Ethernet
port with EtherGate
for direct data transfer
from Ethernet to RS-485
Modbus
RTU and DNP 3.0 protocol support
On-Board Data Logging
Scheduled or event-driven logging of up to
320 parameters
Sequence-of-events & min/max logging
Setpoints for Control and Alarms
Setpoint on any parameter or condition
1 second or 1 cycle operation
Digital Inputs and Outputs
4 optional analog inputs
8 digital inputs
Up to 30 addition I/O points can be ordered
For use by industrial sites, commercial facilities,
utilities, power marketers, and energy service
companies, the ION 7700 offers incredible
flexibility and functionality.
It combines high-accuracy, revenue certified
power and energy measurements, plus an
extensive variety of I/O combinations for
universal metering. Detailed power quality
analysis features keep you informed about your
power distribution system.
Integrate the meter with our ION Enterprise
software or other energy management and
SCADA systems through multiple
communication channels and protocols.
Patented ION technology lets you customize
metering or analysis functions at your
workstation, without any hard-wiring. Just
graphically link a few drag-and-drop icons, or
select default setups, and you're ready to go.
Intelligent metering
and control devices
ION 7700
2
www.pwrm.com
Front Panel Display
The ION 7700 can be enhanced with an optional
MGT, (Modular Graphics Terminal). The MGT
features bright back lighting and adjustable
contrast.
A wide selection of character sizes enhance
visibility under difficult lighting conditions or at
long distances. It provides a choice of 24
customizable screens, (you choose the
parameters and the format) and offers password
protection.
Metering
The ION 7700 offers a comprehensive set of
high-accuracy metering and recording functions.
Energy
The unit is fully bi-directional and meters energy
in four quadrants. It provides active, reactive and
apparent energy parameters and can integrate
any instantaneous power parameter to supply
measurements like Volt-Hours, Amp-Hours, etc.
Energy registers can be logged automatically on
a programmed schedule.
kWh delivered
kWh received
kWh net (delivered- received)
kWh total (delivered + received)
kVARh, kVAh delivered
kVARh, kVAh received
kVARh, kVAh net (delivered - received)
kVARh, kVAh total (delivered + received)
Volt-hours
Amp-hours
Integration of any instantaneous measurement
Demand
The ION 7700 supports all standard demand
calculation methods, including block, sliding
window (rolling interval), thermal (exponential),
and predicted demand. It can be configured to
measure demand on any instantaneous value and
can record peak (maximum) and minimum
demand with accurate date and time stamps to
the second. Peak demand registers can be reset
manually (password protected) or logged and
reset automatically on a programmed schedule.
kW demand, min/max
kVAR demand, min/max
kVA demand, min/max
Amps demand, min/max
Volts demand, min/max
Demand on any instantaneous measurement
Time-Of-Use
2 year internal calendar
Up to 15 daily tariff profiles
Programmable triggers
Separate energy & demand accumulators
Instantaneous
The ION 7700 offers a comprehensive array of
instantaneous (real-time) measurements,
including a choice of high accuracy, 1 second or
high-speed, 1 cycle measurements, including
true RMS, per phase and total for:
Voltage
Current
Active power (kW)
Reactive power (kVAR)
Apparent power (kVA)
Power factor
Frequency
Voltage and current unbalance
Phase reversal
Universal Metering
Accepts input pulses from gas, water, steam, or
other metering equipment. Converts pulses into
actual consumption values.
Power Quality Metering
Waveform Recording
It can simultaneously capture all voltage and
current channels.
Sub-cycle disturbance capture
Up to 14 cycles at 128 samples/cycle
Up to 96 cycles at 16 samples/cycle
Record back-to-back waveforms for up to
several seconds
Display and compare multiple waveforms in
ION ENTERPRISE software
Outage Detection
Advanced setpoint capabilities permit the
detection, recording, and real-time reporting of
outages, including duration, date, time, and
relation to other system conditions.
Out-of-Limit Detection
The meter offers accurate and reliable setpoint
capabilities for the detection, recording, and real-
time reporting of frequency variations, voltage or
current phase imbalances, loss of voltage or
current phase, power factor variations,
overvoltages or undervoltages, etc.
Energy Display
Multiple display formats are available, including bar
graphs with min/max indicators
View Time-Of-Use data via the front panel
ION 7700
3
www.pwrm.com
Performance Indicators
The unit can be configured to meter a wide range
of utility performance indicators, including:
Total outage time (in seconds)
Out-of-tolerance duration for total harmonic
distortion, voltage, frequency, power factor
and hundreds of other definable indices
Harmonic Distortion Metering
Complete harmonic distortion metering,
recording and real-time reporting, up to the 63rd
harmonic, for all voltage and current inputs.
Individual harmonics
Total even harmonics
Total odd harmonics
Total harmonics (even + odd)
K-factor on current inputs
Disturbance Detection
High-speed setpoint capabilities allow reliable
detection and recording of events, sequence-of-
events, and alarm conditions, including
magnitude, duration and equipment status.
Internal waveform recorders are completely
configurable and can record all voltage and
current inputs simultaneously. Control the
number of pre-event and post-event cycles
recorded. Trigger waveform recording with
events, external inputs, or manual control.
Sag/Swell Detection
Monitor and record disturbances caused by poor
power quality.
Magnitude and duration data suitable for
plotting on voltage tolerance curves
Determine the amount of excess or deficient
energy during the disturbance
Per phase triggers for waveform recording or
control operations
Symmetrical Components
Zero, negative and positive sequences including
phase & magnitude for voltage & current inputs.
Identify harmful voltage & current unbalances in
equipment before they cause damage.
Transient Capture
Detect and record sub-cycle transients as
short as 130ms @60Hz (156ms @50Hz)
Analyze transients by plotting them on a
voltage tolerance (e.g. CBEMA) curve using
PC-based ION ENTERPRISE software
Data & Event Recording
The meter can be equipped with up to 4 MB of
meter-based nonvolatile memory, ensuring
important data is never lost, even in the event of
communication or power loss.
Load Profiling
The ION 7700 incorporates 320 channels via 20
data recorders. Channel assignments are
configurable for historical trend recording of
energy, demand, voltage, current, power quality,
or any other measured parameter. Trigger
recorders on a time interval basis, a calendar
schedule, by alarm/event condition, or manually.
High-Speed Data Recording
Use high-speed burst recording (as fast as 1-
cycle intervals) to store detailed characteristics of
disturbances or outages. Trigger recording by a
user-defined setpoint, or from external
equipment. Gated recording logs data only
during the critical event so that memory is
conserved.
Coincident Min/Max Recording
Log the values of key parameters or equipment
conditions coincident with an extreme condition,
complete with date/time stamping. For example,
record all feeder voltages and currents at the
moment a peak demand condition occurs.
Power Quality Recording
Use ION ENTERPRISE software to automatically
upload disturbance waveforms, sag/swell data,
and harmonic distortion measurements from the
meter to the secure database for detailed visual
analysis at your workstation.
Time Synchronization and GPS
A real-time clock allows internal events and data
records to be date-stamped and time-stamped to
millisecond resolution. The clock can be
synchronized to either of t