COLOR MR

hoo! is not affiliated with the authors of this page or responsible for its content.
COLOR MR
GettinG Started
Welcome to a more colorful world brought to you by Color Kinetics.
This guide contains important information not only for operating
your new iColor® MR g2, but also for using it safely. For your
protection, read it carefully before embarking on your colorful
adventure. This guide will show you how to get the most out of your
Color Kinetics lighting.
iColor MR g2 color changing lamp fits most standard, low voltage
MR16 lighting fixtures, including: track, cable, rail, and pendent
styles. Color Kinetics PDS-70mr 24V power/data supply provides
power and data to the iColor MR g2.
included in thiS Box
(1) iColor MR g2 with interchangeable frosted lens
Installation Guide and Warranty Card
additional itemS needed
PDS-70mr 24V Power/Data Supply, (109-000018-00 Series)
MR16 fixture--track, cable, rail, pendent, etc. (No Transformer)
optional itemS
iColor MR g2 Accessory/Adapter ring (101-000050-00)
Scope of thiS uSer Guide
The goal of this user guide is to explain in easily understandable
language the necessary steps to install iColor MR g2 and assure peak
performance. Its intended use is for reference only, by a fully qualified
electrician or technician. This document should never be considered a
substitute for any provision of a regulation or state and/or local code.
owner/uSer reSponSiBilitieS
I
t is the responsibility of the contractor, installer, purchaser, owner,
and user to install, maintain, and operate iColor MR g2 in such
a manner as to comply with all state and local laws, ordinances,
regulations, and the American National Standards Institute
Safety Code.
identification and warninGS of Safety hazardS
In accordance with ANSI Z535.4-2002 the following system of
identifying the severity of the hazards associated with the products
is used:

danger
Imminently hazardous situation which, if not avoided,
will result in death or serious injury. warning
Potentially hazardous situation that, if not avoided,
could result in death or serious injury. caution
Potentially hazardous situation that, if not avoided, may
result in minor or moderate injury or property damage.
danger
: Ensure that main power source (AC line) is off before
installing or wiring iColor MR g2 and PDS-70mr 24V power/data
supply. Failure to adhere to these instructions will result in death or
serious injury.
warning
: iColor MR g2 and PDS-70mr 24V power/data supply
must be installed by a qualified electrician or technician in
accordance with NEC and relevant local codes. Failure to comply
could result in death, serious injury, or property damage.
warning
: Do not attempt to install or use iColor MR g2 or
PDS-70mr 24V until you read and understand the installation
instructions. Failure to adhere to these instructions could result in
serious injury or property damage.
warning
: Do not use iColor MR g2 if any fixture cables are
damaged. Doing so can result in death, serious injury, or property
damage.
caution
: iColor MR g2 works only with PDS-70mr 24V. Using the
iColor MR g2 without the PDS-70mr, or using the PDS-70mr along
with another transformer will result in product failure.
caution
: Use appropriate low voltage, MR16 lighting fixture,
without transformer, and follow manufacturers installation instructions
and safety precautions. Failure to do so will result in product
damage and void the warranty.
caution
: iColor MR g2 has no serviceable parts. Do not attempt to
open
the lights. Doing so will result in property damage and void
the warranty.
caution
: Ensure that fixture tracks, cables, rails, etc. are securely
attached, properly mounted, and free of excessive vibration. Failure
to do so will result in property damage and void the warranty.
caution
: Do not use sharp tools near or on the fixture lens or
cables. Doing so will result in property damage and void the
warranty.
caution
: Do not hot swap. Ensure that power supply is off before
connecting or disconnecting fixtures. Hot swapping will result in
property damage and void the warranty.
caution
: iColor MR g2 may not fit all MR16 lighting fixtures. Verify
fit prior to installation. Optional adapter rings are available to
reduce the overall dimension of the lamp.
caution
: Do not install any other type of MR16 lamp onto the same
light fixture--track, rail, cable--with the iColor MR g2. Doing so will
damage the PDS-70mr and void the warranty.
caution
: Risk of electric shock - use in dry locations only.
caution
: This device is not intended for use with emergency exit
fixtures or emergency exit lights.
note
: The instructions and precautions set forth in this user guide
are not necessarily all-inclusive, all conceivable, or relevant to all
applications as Color Kinetics cannot anticipate all conceivable or
unique situations.
plan the inStallation
T
he nature of iColor MR g2 installation requires in-depth planning
to ensure timely, successful installation and operation with minimal
complications and down time.
inStallation conSiderationS
Consult an Electrical Inspector to approve all wiring plans.
Refer to local and state codes for installation compliance.
Select an appropriate low voltage, MR16 lighting fixture and
follow the manufacturers instructions for installation and wiring.
iColor MR g2 will not work on fixtures with transformers.
Create a Mapping Grid. Use this grid to record light addresses
and power supply locations for easy reference.
Not intended for use in with inclosed or constricted air flow
fixtures, see temperature specifications on page 2.
Environmental temperatures. Refer to specifications on page 2.
Employ Color Kinetics Application Engineering Services.
inStallinG icolor mr g2
Step 1: determine the location of the power Supply
Determine a location out of direct view for the power supply(s).
One PDS-70mr 24V power/data supply is needed for every 14
iColor MR g2 lights.
The power/data supply can be located up to 50 feet (15 m)
from the farthest light.
Refer to the PDS-70mr 24V User Guide for complete installation
instructions.
Step 2: inStall low voltaGe liGht fixtureS
iColor MR g2 lamps plug into standard, low voltage, MR16
lighting fixtures--track, cable, rail, pendent, etc.
Following the manufacturer's installation instructions, install the
low voltage, MR16 fixture, adhering to all safety precautions.
Use only with light fixture without step-down transformer. The
PDS-70mr is the step-down transformer in low voltage MR16
light systems.
iColor MR g2 will not work with low voltage, MR16 fixtures that
have individually attached transformers.
Step 3: wire low voltaGe liGht fixture to pdS-70mr
Using wire nuts, attach 14-18 AWG, 2-conductor, jacketed cable,
or hook-up wire in conduit applications, to the fixture wires.
Pull the attached cable, wires, into the PDS-70mr.
Connect the wires to the large 2-pin terminal block connector.
note
: The PDS-70mr connector circuitry is non-polar; therefore,
either wire can be connected to either terminal.
Provide strain relief for the cable by using a cord grip, Romex
cable clamp, or threaded conduit attached directly to the box or
to a threaded hub. See Fig. 1
Step 4: wire optional acceSSorieS from 24v aux
The 24V Auxiliary Power Out connector can be used to power
certain Color Kinetics accessories such as, iPlayer 2, ColorDial,
Controller Keypad, and Ethernet Controller Keypad. The maximum
load on the auxiliary output is 10 watts. Refer to the accessory
user guide for wiring instructions. See Fig 1.
Step 5: connect data
Data is connected to the iColor MR g2 via the PDS-70mr 24V
power/data supply.
Data connections vary depending on the type data used with the
appropriate PDS-70mr 24V. Refer the figures below.
- Fig. 2: Preprogrammed control
- Fig. 3: DMX control
- Fig. 4: Ethernet control
The PDS-70mr with Preprogrammed control does not require
external data input. Lighting effects are selected using the on-board
controls.
®
Color Kinetics Incorporated
10 Milk Street, suite 1100
Boston, MA 02108
Tel 888 Full RGB
Tel 617 423 9999
Fax 617 423 9998
info@colorkinetics.com
www.colorkinetics.com
icolor mr g2
item# 101-000049-02
item# 101-000049-06 (narrow optics)
This product is protected by one or more of the following patents: U.S. Patent
Nos. 6,016,038, 6,150,774 and other patents listed at http://colorkinetics.com/
patents/. Other patents pending.
©2004-2006 Color Kinetics Incorporated. All rights reserved. Chromacore,
Chromasic, Color Kinetics, the Color Kinetics logo, ColorBlast, ColorBlaze,
ColorBurst, ColorCast, ColorPlay, ColorScape, Direct Light, iColor, iColor Cove,
iPlayer, Optibin, Powercore, QuickPlay, Sauce, the Sauce logo, and Smartjuice are
registered trademarks and DIMand, EssentialWhite, eW, IntelliWhite, iW, and Light
Without Limits are trademarks of Color Kinetics Incorporated.
All other brand or product names are trademarks
or registered trademarks of their respective owners.
PUB-000112-00 Rev 04
Specifications subject to change without notice.
i
COLOR MR

g
2
i n s t a l l a t i o n

g u i d e
caution
:
Ensure the power is off before installing iColor
MR g2 lights. Failure to do so can result in property damage.
warning
: iColor MR g2 light systems should be installed by a
qualified electrician or technician in accordance with NEC and
relevant local codes.
DMX/ETHERNET
IN
DMX
OUT
24V Auxiliary Power Out
Maximum output: 10W max.
24V Output
to Lights
To optional accessories
such as, iPlayer 2, ColorDial,
or Controller Keypads
To Low voltage,
2-wire track
(without transformer)
or MR-16 fixtures
wired in parallel
fig. 1:
light connection
OUT