3KP70 MAN SB.1

d>
3KP70 MAN SB.1 3000PLUS
WITH
5D70 I
NSTRUCTION
M
ANUAL
V. SB.2
Daytronic Corporation
2211 Arbor Blvd. Dayton, OH 45439 (800) 668-4745
Tel: (937) 293-2566 Fax: (937) 293-2586 www.daytronic.com
Copyright © 2005, Daytronic Corporation. All rights reserved.
No part of this document may be reprinted, reproduced, or used in any form or by any electronic,
mechanical, or other means, including photocopying and recording, or in any information storage
and retrieval system, without permission in writing from Daytronic Corporation.
All specifications are subject to change without notice.
V
ERSION
SB.2
M
ANUAL
P
ART
N
O
. 92322
3000PLUS P
ANEL
M
ETER
WITH
M
ODEL
5D70
DC S
TRAIN
G
AGE
C
ONDITIONER
M
ODULE
I
NSTRUCTION
M
ANUAL 3KP70 - ii
3000PLUS
WITH
5D70 I
NSTRUCTION
M
ANUAL
V. SB.2
Daytronic Corporation
2211 Arbor Blvd. Dayton, OH 45439 (800) 668-4745
Tel: (937) 293-2566 Fax: (937) 293-2586 www.daytronic.com
PLEASE NOTE
This manual treats the setup and use of a 3000PLUS meter in which a
Daytronic
Model 5D70 DC Strain Gage Conditioner Module
has been properly installed. If your 3000PLUS is equipped with a 5D Series
conditioner model other than the 5D70, the corresponding instruction manu-
al should be consulted.
ALWAYS TURN OFF THE 3000PLUS BEFORE REMOVING ITS INSTALLED 5D
SERIES CONDITIONER MODULE, OR INSTALLING A DIFFERENT MODULE
IN THE 3000PLUS CHASSIS. DO NOT REPLACE THE INSTALLED CONDI-
TIONER MODULE WHILE THE 3000PLUS IS ON. 3KP70 - iii
3000PLUS
WITH
5D70 I
NSTRUCTION
M
ANUAL
V. SB.2
Daytronic Corporation
2211 Arbor Blvd. Dayton, OH 45439 (800) 668-4745
Tel: (937) 293-2566 Fax: (937) 293-2586 www.daytronic.com
1
I
NTRODUCTION
T
ABLE OF
C
ONTENTS
1.
A
General Description and Specifications ........................................................................ 3KP70 - 1.1
1.
B
Physical Layout ......................................................................................................................... 3KP70 - 1.5
1.
C
Panel Mounting ......................................................................................................................... 3KP70 - 1.6
1.
D
Data and Status Display ........................................................................................................ 3KP70 - 1.7
1.
E
Front-Panel Button Functions ............................................................................................... 3KP70 - 1.9
1.
F
Installing and Running the 3000Plus Configurator Software ............................. 3KP70 - 1.11
2.
A
Power Connections ................................................................................................................ 3KP70 - 2.1
2.
B
Serial Communications Connections ............................................................................. 3KP70 - 2.2
2.
C
Transducer Connections ...................................................................................................... 3KP70 - 2.3
2.
D
Analog Output Connections ............................................................................................... 3KP70 - 2.4
2.
E
Logic I/O Connections ............................................................................................................ 3KP70 - 2.5
3
F
RONT
-P
ANEL
C
ONFIGURATION AND
C
ALIBRATION
3.
A
Introduction ................................................................................................................................. 3KP70 - 3.1
3.
B
Front-Panel Setup Procedure ............................................................................................. 3KP70 - 3.4
4
S
OFTWARE
C
ONFIGURATION AND
C
ALIBRATION
4.
A
Using the 3000Plus Configurator Software ................................................................... 3KP70 - 4.1
4.
B
Summary of Configurator Menus ..................................................................................... 3KP70 - 4.3
4.
C
Overview of OFF-LINE Configuration ............................................................................ 3KP70 - 4.4
4.
D
Overview of ON-LINE Configuration ............................................................................ 3KP70 - 4.5
4.
E
Software Calibration of the 3000PLUS with 5D70 ..................................................... 3KP70 - 4.7
5
O
PERATING
C
ONSIDERATIONS
5.
A
Sending a Command to the 3000PLUS ........................................................................ 3KP70 - 5.1
5.
B
Capturing a Signal Peak ........................................................................................................ 3KP70 - 5.1
5.
C
Applying a Signal Hold ........................................................................................................... 3KP70 - 5.5
5.
D
Applying a Tare Offset ............................................................................................................ 3KP70 - 5.5
5.
E
Limit Monitoring ........................................................................................................................ 3KP70 - 5.7
5.
F
Applying a Positive or Negative Calibration Shunt .................................................... 3KP70 - 5.9
2
C
ONNECTIONS
A
PPENDIX
A
S
UMMARY OF
M
NEMONIC
C
OMMANDS
A.
1 Command and Response Syntax .................................................................................... 3KP70 - A.1
A.
2 Model 5D70 Setup and Interrogation Commands ................................................... 3KP70 - A.2
A.
3 Model 5D70 Imperative Commands ............................................................................... 3KP70 - A.3
(contd) 3KP70 - iv
3000PLUS
WITH
5D70 I
NSTRUCTION
M
ANUAL
V. SB.2
Daytronic Corporation
2211 Arbor Blvd. Dayton, OH 45439 (800) 668-4745
Tel: (937) 293-2566 Fax: (937) 293-2586 www.daytronic.com
I
LLUSTRATIONS
T
ABLES
Table 1
Model 5D70 Full-Scale Ranges (Nominal) and
Accuracy per Excitation Setting ................................................................................................. 3KP70 - 1.4
Table 2
Practical 5D70 Range (RNG) Settings ............................................................. 3KP70 - B.1
A
PPENDIX
B 5D70
A
BSOLUTE
C
ALIBRATION
C
ALCULATIONS
................................................................................. 3KP70 - B.1
A.
4 3000PLUS Setup and Interrogation Commands ...................................................... 3KP70 - A.4
A.
5 3000PLUS Imperative Commands .................................................................................. 3KP70 - A.6
Fig. 1
3000PLUS Dimensions .................................................................................................... 3KP70 - 1.3
Fig. 2
3000PLUS Front Panel Elements ................................................................................ 3KP70 - 1.5
Fig. 3
3000PLUS / 5D70 Module Rear Panel Elements ................................................ 3KP70 - 1.5
Fig. 4
3000PLUS Panel Mounting ............................................................................................ 3KP70 - 1.6
Fig. 5
Panel Cutout Dimensions ............................................................................................... 3KP70 - 1.6
Fig. 6
3000PLUS Power Connections .................................................................................... 3KP70 - 2.1
Fig. 7
RS232 Interface Connections ....................................................................................... 3KP70 - 2.2
Fig. 8
Model 5D70 Transducer Connections
Fig. 8.a
4-Wire Strain Gage Cabling (under 20 ft. in length) ................................... 3KP70 - 2.3
Fig. 8.b
8-Wire Strain Gage Cabling (20 ft. or longer) ............................................... 3KP70 - 2.3
Fig. 9
Analog Output Connections .......................................................................................... 3KP70 - 2.4
Fig. 10 3000PLUS Logic I/O Connections
Fig. 10.a Logic Inputs with Switch Closure, Using External Supply ....................... 3KP70 - 2.5
Fig. 10.b Logic Input with Active TTL Logic ...................................................................... 3KP70 - 2.6
Fig. 10.c Logic Outputs (Relay and TTL) ........................................................................... 3KP70 - 2.6
Fig. 11 3000PLUS Configurator Live Output Window .................................................... 3KP70 - 4.6
Fig. 12 Typical Asymmetry ............................................................................................................ 3KP70 - 4.8
Fig. 13 Absolute Calibration Page for Installed Model 5D70 ......................................... 3KP70 - 4.9
Fig. 14 Two-Point Calibration Page for Installed Model 5D70 ..................................... 3KP70 - 4.11
Fig. 15 Typical Positive Peak Capture ...................................................................................... 3KP70 - 5.2
Fig. 16 Typical Positive Peak Reset ........................................................................................... 3KP70 - 5.3
Fig. 17 Peak Defeat Input Threshold ......................................................................................... 3KP70 - 5.3
Fig. 18 Peak Trend Monitoring Using Adjustable Leak Rate .......................................... 3KP70 - 5.4
Fig. 19 Application of Tare Offset ................................................................................................ 3KP70 - 5.6
Fig. 20 3000PLUS Limit Zones ..................................................................................................... 3KP70 - 5.7 3KP70 - 1.1
3000PLUS
WITH
5D70 I
NSTRUCTION
M
ANUAL
V. SB.2
Daytronic Corporation
2211 Arbor Blvd. Dayton, OH 45439 (800) 668-4745