Insolroll Motor with Built-In Radio Remote Receiver

ults for ""
Below
is a cache of http://www.insolroll.com/PDFs/BldgAuto_BuiltInRadioMotors.pdf. It's a snapshot of the page taken as our search engine crawled the Web.
The web site itself may have changed. You can check the current page or check for previous versions at the Internet Archive. Yahoo! is not affiliated with the authors of this page or responsible for its content.
Insolroll Motor with Built-In Radio Remote Receiver Insolroll Motor with Built-In
Radio Remote Receiver
637 S. Pierce Ave., Louisville, CO 80027 USA
800-447-5534 / Fax 303-665-1209
www.insolroll.com
RR-8
-Attachment of a three-prong AC plug allows motor to be operated by plugging it into a
standard outlet
-All wiring must conform to the National Electrical Code and local codes
-The operator can be wired in parallel (unlike normal AC tubular motors)
It is recommended that provisions be made to cut power individually when wiring motors with
built-in radio receivers. This can be in the form of an inline off/on switch, a disconnect plug,
or access to the operator cable for use of an installers power cable with off/on switch. The
ability to cut the power to each motor individually is required to easily program the receiver in
the operator
-Mount motor heads at least 18 inches from each other to prevent RF interference
-Always install the power cable with a drip loop to prevent water penetration
-Each motor has 14 capable addresses
-Individual, sub-group and all operation can be
accomplished
-The motor has a built-in thermal cut-off. Allow motor to
cool for approx. 20 minutes if you cannot get motor to
run in either direction
-Battery: 3V Lithium CR 2430 in Transmitter Radio Remote Control Systems
Transmitter Overview
637 S. Pierce Ave., Louisville, CO 80027 USA
800-447-5534 / Fax 303-665-1209
www.insolroll.com
RR-9
5 Channel
In-Wall Wireless
Wall Switch
5 Channel
Hand Held Transmitter
Single Channel
In-Wall Wireless
Wall Switch
Single Channel
Hand Held Transmitter
Single Channel
Surface Mount
Wireless Wall Switch
Transmitter must be within 70 ft of motor heads
Each transmitter can control an unlimited number of motors
4 Channel Transmitter has 5 channel group capability
Transmitter/Wall switches work in conjunction with:
Built-In Radio Receiver Motor
Eolis Receiver
Centralis Receiver
Soliris 1 Channel Transmitter
Transmitter works in
conjunction with Soliris
Receiver and Soliris
Sensor
Radio Remote Control with Chronis Timer
Chronis Timer is a wireless digital timer
compatible with all new radio receivers
(Centralis, Eolis, Soliris and Built-In Radio
Receiver Motor) Insolroll 110 Volt Tubular Motor
Limit Switch Adjustment Instructions
637 S. Pierce Ave., Louisville, CO 80027 USA
800-447-5534 / Fax 303-665-1209
www.insolroll.com
) 1) Identify which limit adjustment screw controls the up limit and which controls the down limit (see
above diagrams). It is important to note arrows by the limit adjustment screw refer to the tubes rotation.
Thus if the material comes off the tube on the back side and limit adjust screws face the front (as per
diagram 2), the limit adjustment screw facing up controls the down limit and vice versa.
) 2) Turning an adjustment screw clockwise will increase the maximum travel in the direction that it
controls, and turning it counterclockwise will decrease the maximum travel.

) 3) To set a limit, run the motor in the selected direction.

) 4) If the motor stops on its own before reaching the desired stop, turn the appropriate limit screw positive
(clockwise). Every 2 to 3 turns of the adjustment screw will allow the motor to travel about 1 inch
further. After every few turns of the limit adjustment screw, use the control switch to run the motor to the
new limited position. (If the motor does not stop on its own before reaching the desired limit, go to step
6.)

) 5) When you are approximately at the desired limit position, use the control switch to run the motor away
from the limit 2 to 3 feet, and then return to limit. This will allow you to see precisely where the limit is
set. Make small adjustments and repeat.

) 6) If the motor does not stop on its own at least 6 inches before the desired limit position, stop the motor
with the control switch. Then turn the adjustment screw in the negative (counterclockwise) direction.
Confirm that the motor is stopped at the limit as per step 4 and 5. If the motor is not stopped at the limit,
continue turning the limit adjustment screw counterclockwise (up to 120 turns may be required).

NOTE: The motor has a built in thermal cutoff. If after several minutes of use the motor will not run in
E either direction, allow the motor to cool down approximately 20 minutes.
Material rolls down on same side as limits Material rolls down on opposite si de as limits
S-10 RED
BLACK
GREEN
WHITE
RTS DRY-CONTACT INTERFACE
Operating Instructions
SOMFY SYSTEMS, INC. 3/02
C
SOMFY SYSTEMS, INC.
47 Commerce Drive
Cranbury, NJ 08512
SOMFY CANADA
6315 Shawson Drive, Unit #1
Mississauga, Ontario L5T1J2
SOMFY MEXICO S.A. De C.V.
Calle 3 No.47, Loc.E-5
Fracc Ind. Alce Blanco
Nau.,Edo. de Mex C.P. 53370,Mex
SOMFY SYSTEMS, INC. reserves the right to change,
update or improve this document without prior notice.
Battery Holder
Programming Button
NOTE: Please Consult RTS Motor Instructions for Specific Product Details.
1.
2.
3.
4.
5.
Place the RTS Motor in Programming Mode as described in the individual product operating
instructions.
Press the programming button on the RTS Interface to program it in the memory of the RTS Motor.
To activate an UP command, a momentary contact (relay) closure is required between the WHITE and
GREEN wires.
To activate a DOWN command, a contact closure is required between the BLACK and GREEN wires.
To activate a STOP command or Intermediate Position, a contact closure is required between the RED
and GREEN wires.
The RTS dry-contact Interface (Catalog 6300454) can be used to communicate between home automation
or other third party systems and SOMFYs RTS Motors and Inteo line of controls. 637 S. Pierce Ave., Louisville, CO 80027 USA
800-447-5534 / Fax 303-665-1209
www.insolroll.com
Insolroll 5 Channel RTS Interface Module
(dry contact, RS232 or IR inputs)
SA 23
1) Range is 65' to shades.
2) That number is deminished
when the box is located anywhere
near metal or steel.
3) 5 Channel RTS modules must
be located 12" apart.
1 5/8"
5 3/8"
5 1/8" A. INITIAL SETUP
1. Connect a 9v DC transformer (included) to the plug on the top of the control box. The bottom LED will light to indicate power.
2. Be careful not to mount or enclose Interface on or in metal, as this may effect radio reception.
3. Set the RTS Receiver or motor into its Programming Mode. Refer to the installation instructions of the relevant RTS receiver or motor for this
procedure. NOTE: for initial programming provide power only to the motor or control being programmed.
4. Select the channel to be memorized by pressing the SET button on the RTS Interface until the corresponding LED blinks. Briefly press the
programming (PGM) button (1 sec. max). Channel 5 is indicated by all LEDs blinking.
5. The RTS Receiver or motor will respond in its appropriate manor, as outlined in the specific operating instructions.
6. Repeat the steps above for each channel or product to be memorized.
B. DRY CONTACT INPUTS
1. Wire dry-contact relay outputs to the indicated terminals at the bottom of the RTS Interface control box.
2. To activate an UP command, a minimum 0.5 second closure is required between the UP and COM terminals. The top LED on the top of the
control box will blink to indicate signal is sent.
3. To activate a DOWN command, a minimum 0.5 second closure is required between the DOWN and COM terminals.
4. To activate a STOP command, a closure is required between all three terminals.
5. NOTE: There needs to be a 1.5 second delay between successive commands.
C. INFRARED OPERATION
1. The RTS Interface is compatible with Somfys Single & 8 Channel transmitters. Connect an infrared sensor to the indicated terminal on the
bottom of the Interface control board.
2. Each individual motor is activated by first aiming the transmitter at the sensor and pressing the desired unit number on the transmitter and then
pressing the UP or DOWN buttons. Press the center button to STOP the window treatment at any time.
3. NOTE: There needs to be a 1.5 second delay between successive directional commands or address ranges.
D. RS232 OPERATION
1.
The Somfy RS232 interface uses the following communications settings:
1200 Baud, 8 Data Bits, 1 Stop Bit, No Parity
2. The commands are as follows: (Case sensitive, ASCII)
U1
S1
D1
UP, STOP and DOWN commands for Unit 1
U2
S2
D2
UP, STOP and DOWN commands for Unit 2
U3
S3
D3
UP, STOP and DOWN commands for Unit 3
U4
S4
D4
UP, STOP and DOWN commands for Unit 4
U5
S5
D5
UP, STOP and DOWN commands for Unit 5
3. NOTE: There needs to be a 1.5 second delay between successive commands.
OPERATION
Ref. No. 2500554 REV. A
SOMFY SYSTEMS, INC. 9/04
C
SO