Smoke Alarm
Year
Limited
Warranty
An ISO 9001 2000 Certified Company
Items: 4480
480
480C (Canada)
484
484C (Canada)
FireX photoelectric smoke alarms
respond to slow burning, visible
smoke caused by smoldering fires.
Designed for use in kitchens and
furnace rooms, they reduce nuisance
alarms caused by cooking fumes or
high humidity.
With state-of-the-art production
testing equipment and installer
focused innovations, FireX products
have earned their reputation as the
most preferred alarms among
contractors.
Advanced photoelectric design Fast detection of slow, smoldering fires.
Installation design and features similar to other FireX smoke alarms Contractor familiarity
with installation.
Interconnects with most FireX smoke, carbon monoxide and heat alarms Compatible with
other contractor preferred FireX products (except item 480).
Lighted Power/Alarm LED Confirms unit is receiving power and provides visual indication of ini-
tiating alarm in interconnected systems.
Incorporates FireX installer-focused innovations Fastest and easiest installation available.
Factory sealed housing Prevents tampering and provides outstanding durability.
The FireX
480(C), 484(C), and 4480 are photoelectric smoke alarms. These units have an 85 deci-
bel horn, test button, and lighted power/alarm LED indicators. The 4480 and 484(C) AC smoke
alarms can be interconnected with FireX ionization as well as photoelectric smoke alarms for the
best smoke detection system.
4480 120V AC Direct Wire with Battery Back-up for single or multiple station use. The 4480 is
interconnectable with up to 12 FireX AC/DC smoke alarms and 6 FireX heat or carbon
monoxide alarms for a total of not more than 18 FireX devices. This unit has two separate
lighted LEDS green power-on LED confirms constant AC power and the red LED displays
alarm/battery status.
484
120V AC Direct Wire for single or multiple station use. The 484 is interconnectable with up
to 12 FireX AC smoke alarms. A green lighted LED blinks once per minute to confirm
constant AC power and once per second when in alarm.
480
9V DC Battery Powered with a green lighted LED that blinks once per minute to confirm
DC power and once per second in alarm. Alarm features a 30 day low battery indicator.
These FireX smoke alarms should be placed in single-family households or in each individual living
unit of multiple-family buildings. All smoke alarms should be replaced every 10 years.
120V AC
Direct Wire
with Battery
Back-up
120V AC
Direct Wire
9V DC
Battery
Powered
S
TA
TE
OF CALIFORNIA
STATE FIRE MARSHAL
L I
S T I N G
S E R V I C E
480
484
4480
Smoke Alarm
Photoelectric
Smoke Alarms
Technical Specifications
Ordering Data
Installation
Architectural Specifications
191 E. North Avenue
Carol Stream Illinois 60188 USA
Customer Service Telephone 1.800.951.5526
Customer Service Facsimile 1.630.260.7299
iccacustomerservice@invensys.com
www.FireXsafety.com
2007 Invensys Controls
For Technical Service
Telephone 1.800.445.8299
Facsimile 1.630.260.7243
technicalservice@invensys.com
3505 Laird Road Unit #14
Mississauga Ontario L5L 5Y7 Canada
Customer Service Telephone 1.800.387.7978
Customer Service Facsimile 1.905.828.1265
iccacustomerservice@invensys.com
Invensys
and FireX
are trademarks of Invensys
plc., its subsidiaries or affiliated companies.
The 4480 shall be 1-3/8 high and 5 wide, powered by a 120V AC, 60 Hz source
with a 9 volt battery back-up. Nominal sensitivity shall be measured by U.L. at obs.
2.3 .95%/ft. A green continuous power on indicator shall be a built-in light emit-
ting diode (LED) in the standby condition; a second red blinking LED shall indicate
that a sufficient 9-volt battery back-up is present; when activated, the initiating
alarm red LED shall flash while the interconnected alarms remain extinguished. A
7 day low battery signal shall be included.
The 484(C) shall be 1-3/16 high and 4-7/8 wide powered by a 120V AC, 60 Hz
source. Nominal sensitivity shall be measured by U.L. at obs. 2.2 1.2%/ft. and by
U.L.C. at obs. 2.2 .75%/ft. A power-on indicator shall be a built-in LED which
blinks once per minute in the standby condition; when activated, the initiating
alarm LED shall flash while the interconnected alarms remain extinguished.
The 4480 and the 484(C) shall be rated at no more than 0.5W in standby and have
100% solid state alarm circuits over an input range of 100-130V AC. The alarm
shall mount to a single gang box, 4 octagon junction box, or a square-to-round
drywall ring without screw removal. It shall have a Quick Connect wiring harness.
The 480(C) shall be 1 high and 4 wide powered by a 9V DC battery source.
Nominal sensitivity shall be measured by U.L. at obs. 2.2 1.2%/ft. and by
U.L.C. at obs. 2.2 .75%/ft. 100% solid state alarm circuits over an input range of
6.8-10V DC. A power-on indicator shall be a built-in LED which blinks once per
minute in the standby condition and a 30 day low battery signal shall be included.
All FireX photoelectric smoke alarms shall have a photoelectric sensor. Operating
temperature range shall be between 40 and 100癋 (4-38癈) and relative humid-
ity range between 10%-93%. The test switch shall electronically activate the
chamber to simulate smoke and check for proper operation. The electric horn shall
have a level of 85 decibels at 10 feet and all units have a separate mounting
bracket. Items 4480, 484, 480 shall meet the requirements of U.L. 217 and items
484(C) and 480(C) shall meet the requirements of U.L.C. S531.
4480 / 484 / 484C
480 / 480C
Individual Carton
5-1/8" x 5-1/8" x 1-1/2"
4-1/8" x 4-1/8" x 1-1/2"
Dimensions
13cm x 13cm x 3.8cm
10.5cm x 10.5cm x 3.8cm
Master Carton
12
12
Quantity
Master Carton
10-3/4" x 10-1/2" x 5-3/4"
9-3/8" x 8-3/4" x 4-7/8"
Dimensions
27.3cm x 26.7cm x 14.6cm
23.8cm x 22.2cm x 12.4cm
Master Carton
4480 - 6.4 lbs. / 2.9 kg.
480(C) - 3.5 lbs. / 1.6 kg.
Weight
484(C) - 4.5 lbs. / 2 kg.
Pallet Quantity
864
2160
Pallet Dimensions 40"L x 48"W x 40.5"D
48"L x 40"W x 48.3"D
102cm x 122cm x 103cm
122cm x 102cm x 123cm
This smoke alarm should be installed in accordance with NFPAs Standard
72 (National Fire Protection Association, Batterymarch Park, Quincy, MA
02269) and any local codes that apply. For the AC and AC/DC direct wire
smoke alarms, use #18 AWG minimum solid or stranded wire. When inter-
connecting, maximum wire length between any two is 1,500 feet for #18
AWG or 4,000 feet for #14 AWG (20 OHMS loop resistance). DO NOT con-
nect to any other type or model of heat or smoke alarm. Connect smoke
and heat alarms to a single AC branch circuit. If local codes do not permit,
be sure the neutral wire is common to both phases.
5/07 150-1358F
120V AC
Direct Wire
with Battery
Back-up
120V AC
Direct Wire
9V DC
Battery
Powered
WHITE
WHITE
WHITE
YELLOW
YELLOW
BLACK
BLACK
BLACK
TO NEUTRAL
TO 120 VAC
4480
484
484C
480(C)
Product Weight
8 oz.
5.5 oz.
4.2 oz.
Operating
Temperature
40癋 to 100癋
(4癈 to 38癈)
Interconnect
Quantity
Up to 18 FireX alarms, up to 12 of which can be
smoke alarms. FireX smoke alarm items 12000
(model FADCM), 5000 and 4618 (model FADC),
4518 (model ADC), 4418 (model AD), 4580 (model
FAPD), 4480 (model PAD), 4671 (model TPCI), 484
(model PG), 406 (model G), FireX heat alarm 5700
(model ADH), FireX CO alarm 10000 (model COE).
Up to 18 FireX alarms, up to 12 of which
can be smoke alarms. FireX smoke alarm
items 12000C (model FADCM), 12400C
(model GCM), 4518C (model ADC), 4671C
(model TPCI), 418C and 406C (model G-
18), FireX CO alarms 10000C (model
COE), 10400C (model COEA).
Electrical
Rating
120V AC, 60 Hz,
50mA max.
with 9V DC
battery back-up
120V AC, 60 Hz, 50mA max.
9V DC
battery
Alarm Point
2.30.95%/ft.
obs.
2.21.2%/ft. obscuration (US)
2.2.75%/ft. obscuration (Canada)
Horn Output
85 decibels at 10 feet
Listing
UL 217
UL 217
ULC S531
UL 217
Detection Type
Photoelectric
Humidity Range
10% to 93% relative humidity
* Heat alarm item. Interconnectable up to 12 FireX AC/DC smoke alarms and
6 FireX heat alarms.
Shipping Specifications
Item No.
Model No.
Agency Listing
Packaging
4480
PAD
UL
carton
480
PB
UL
carton
480C
PB
CUL
carton
484
PG
UL
carton
484C
PG
ULC
carton