INSTRUCTION MANUAL MODEL 1583-09 Data Splitter

ue>the Internet Archive. Yahoo! is not affiliated with the authors of this page or responsible for its content.
INSTRUCTION MANUAL MODEL 1583-09 Data Splitter
INSTRUCTION MANUAL
MODEL 1583-09 Data Splitter

Data, drawings, and other material contained herein are proprietary to
Cross Technologies, Inc., but may be reproduced or duplicated without the
prior permission of Cross Technologies, Inc. for purposes of operating the
equipment.
When ordering parts from Cross Technologies, Inc., be sure to include the
equipment model number, equipment serial number, and a description of
the part.
First Edition,
May 1997
Rev 0
March 2006
Rev A
C
ROSS
T
ECHNOLOGIES INC.
6170 SHILOH ROAD
ALPHARETTA, GEORGIA 30005
(770) 886-8005 (PHONE)
(770) 886-7964 (FAX)
1-888-900-5588 (TOLL FREE)
www.crosstechnologies.com
info@crosstechnologies.com INSTRUCTION MANUAL
MODEL 1583-09 Data Splitter
TABLE OF CONTENTS
PAGE
Warranty

2
1.0 General
3
1.1 Equipment Description
3
1.2 Technical Characteristics
3
2.0 Installation
4
2.1 Input & Output Connectors
4
2.2 Indicators
5
2.3 Mechanical
5
2.4 Installation/Operation
5
WARRANTY - The following warranty applies to all Cross Technologies, Inc. products.
All Cross Technologies, Inc. products are warranted against defective materials and
workmanship for a period of one year after shipment to customer. Cross Technologies,
Inc.s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc.s
option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall
not be liable for any special, indirect, or consequential damages. This warranty does not
cover parts or equipment which have been subject to misuse, negligence, or accident by the
customer during use. All shipping costs for warranty repairs will be prepaid by the
customer. There are not other warranties, express or implied, except as stated herein.
CROSS TECHNOLOGIES, INC.
6170 SHILOH ROAD
ALPHARETTA, GEORGIA 30005
(770) 886-8005 (PHONE)
(770) 886-7964 (FAX)
1-888-900-5588 (TOLL FREE)
www.crosstechnologies.com
info@crosstechnologies.com
1583-09 Manual, Rev A
Page 2
03/15/2006 INSTRUCTION MANUAL
1583-09 DATA SPLITTER
1.0 General
1.1 Equipment Description
The 1583-09 Data Splitter provides 9 RS232C outputs of the data signal (pin 2 of the DB9 connector). One of the outputs is
a hard wired pass through of the input which can be used for very important functions or to further split the data. Dual
power supplies provide redundant power to the 1583-09 with front panel LEDs indicating proper power supply operation.
The unit is housed in a 1 3/4, rack mount chassis and all data connectors are DB9, female.
MODEL 1583
C
ROSS
T
ECHNOLOGIES INC.
POWER
DATA SPLITTER
1
2
FIGURE 1.0 1583-09 DATA SPLITTER
1.2
Technical Specifications
Data Characteristics
Input/Output RS232C
Data rate
128 kB/s max
Number of outputs
1 - Hard wired loop of the input
8 - Buffered RS232C outputs
Connector
DB9, female
Indicators
POWER CH1 LED
Turns green when power is applied to number 1 input
on the rear panel
POWER CH2 LED
Turns green when power is applied to number 2 input
on the rear panel
Other
Mechanical
19 inch standard chassis 1.75high X 7.5 deep
Power
115 ± 10 VAC, 60Hz, 10 watts
1583-09 Manual, Rev A
Page 3
03/15/2006 2.0 Installation
2.1 Input/Output Connectors
T</b>he following are the input and output connectors.
FAC1
MONITORS & CONTROLS
1
14
1,2,34,5,6-NOT USED
3,7,10 GROUND
8 - MAN O.C.
9 - REMOTE O.C.
11 - SW 1 MONITOR
12 - SW 2 MONITOR
13 - ALARM 1 O.C.
14 - ALARM 2 O.C.
FAC2
J3
J4A
J4B
J5A
J5B
TOP - DATA OUT A
BOT - DATA OUT B
TOP - DATA OUT C
BOT - DATA OUT D
J6A
J6B
J7A
J7B
TOP - DATA OUT E
BOT - DATA OUT F
TOP - DATA OUT G
BOT - DATA OUT H
J9A
J9B
J8A
J8B
TOP - DATA 2 IN
BOT - OFF LINE DATA
TOP - DATA 1 IN
BOT - DATA OUT
AC1
GND
AC2
POWER IN 1
J8A-DATA IN
J8B-HARD WIRED
DATA OUT
1/4 A FUSE 1 1/4 A FUSE 2
J5A-DATA-C
J4A-DATA-A
J7A-DATA OUT-G
J6A-DATA OUT-E
POWER IN 2
J5A-DATA OUT-D
J4A-DATA OUT-B
J7A-DATA OUT-H
J6A-DATA OUT-F
FIGURE 2.0 1583-09 REAR PANEL

TABLE 2.0 INPUT / OUTPUT CONNECTORS
J4, J5, J6, J7, J8, - DATA CONNECTORS (FIGURE 2.1)
Function
Pin #
Description
DATA
2
RS232C Data
GROUND
1,5
Ground
NO CONNECTION
3,4,6,7,8,9 No Connection
AC1, AC2 - POWER IN - Provides AC inputs for dual power supplies.
FAC1, FAC2 - 1/4 AMP FUSES - 1/4 AMP fast blow 115 VAC fuses for the dual power supplies.
5 4 3 2 1
9 8 7 6
FIGURE
2.1 DB9 PINOUT
1583-09 Manual, Rev A
Page 4
03/15/2006 2.2 Indicators
The following are the front panel indicators. There are no controls to adjust.
MODEL 1583
DATA SPLITTER
POWER
1
C
ROSS
T
ECHNOLOGIES, INC.
2
C
ROSS
T
ECHNOLOGIES, INC.
FIGURE 2.2 1583-09 INDICATORS
TABLE 2.1 FRONT PANEL INDICATORS
Item
Description
POWER CH1 LED
Turns green when power is applied to number 1 input on the rear panel
POWER CH2 LED
Turns green when power is applied to number 2 input on the rear panel
2.3 Mechanical
The 1583-09 is rack mounted by attaching the front panel to a rack through the four holes at the edges of the panel.
2.4 Installation/Operation
1. Install the 1583-09 in the equipment rack.
1.1. Elevated operating ambient - If installed in a closed or multi-unit rack assembly, the operating ambient of the
rack may be greater than the room ambient. Thereofre, considerations should be given to the Tmra.
1.2. Reduced air flow - Installation of the equipment in a rack should be such that the amount of air flow required
for safe operation of the equipment is not compromised.
1.3. Mechanical loading - Mounting of equipment in a rack should be such that a hazardous condition is not
achieved due to uneven loading.
1.4. Circuit overloading - Consideration should b e given to the connection of the equipment to the supply circuit
and the effect that overloading of cicuits could have on overcurrent protection and supply wiring. Appropriate
consideration of equipment nameplate ratings should be given supply connections.
1.5. Reliable earthing - Reliable earthing of rack mounted euipment should be maintained. Particular attention
should be given to supply connections other than direct connection to the Branch (use of power strips).
2. Connect data to the RS232C DB-9 DATA INPUT (J8A) and DATA OUTPUT connectors (J5A,B, J6A,B, J7A,B,J8B).
Note that J8B is a hard wired loop of the input and will always pass data even when power is off.
3. Connect power via two power cords.
4. Check that data is present at all data outputs.
1583-09 Manual, Rev A
Page 5
03/15/2006