UB-530 Breakout Panel






















Part Number MN/UB530.IOM
Revision 2


UB-530
Breakout Panel
Installation and Operation Manual




Copyright © Comtech EF Data, 2000-2003. All rights reserved. Printed in the USA.
Comtech EF Data, 2114 West 7th Street, Tempe, Arizona 85281 USA, 480.333.2200, FAX: 480.333.2161.





UB-530
Breakout Panel
Installation and Operation Manual


Part No. MN/UB530.IOM
Revision 2
June 2, 2004
Comtech EF Data is an ISO 9001
Registered Company. ii
Customer Support
Contact the Comtech EF Data Customer Support Department for:

Product support or training
Information on upgrading or returning a product
Reporting comments or suggestions concerning manuals

A Customer Support representative may be reached at:

Comtech EF Data
Attention: Customer Support Department
2114 West 7th Street
Tempe, Arizona 85281 USA

480.333.2200 (Main Comtech EF Data Number)
480.333.4357 (Customer Support Desk)
480.333.2161 FAX

or, E-Mail can be sent to the Customer Support Department at:

service@comtechefdata.com

Contact us via the web at
www.comtechefdata.com
.

1. To return a Comtech EF Data product (in-warranty and out-of-warranty) for
repair or replacement:

2. Request a Return Material Authorization (RMA) number from the Comtech EF
Data Customer Support Department.

3. Be prepared to supply the Customer Support representative with the model
number, serial number, and a description of the problem.

4. To ensure that the product is not damaged during shipping, pack the product in
its original shipping carton/packaging.

5. Ship the product back to Comtech EF Data. (Shipping charges should be
prepaid.)

For more information regarding the warranty policies, see Warranty Policy, p. viii.
iii
Table of Contents


Chapter 1. Introduction ......................................................................................................................................... 1-1

Chapter 2. Connectors and Switches .................................................................................................................... 2-1

2.1 Switches .......................................................................................................................................................... 2-2

2.2 Connectors....................................................................................................................................................... 2-2


Figures
Figure 1-1. UB-530 Breakout Panel...................................................................................................................... 1-1
Figure 2-1. UB-530 Front and Rear View............................................................................................................. 2-1
Figure 2-2. UB-530 to UB-300 Adapter for 25-Pin V.35 Connector (J3)..............................................................2-9

Tables
Table 2-1. UB-530 Configuration Switch Selections............................................................................................ 2-2
Table 2-2. UB-530 Breakout Panel Connectors .................................................................................................... 2-2
Table 2-3. Adapter Pinout for UB-530 to UB-300 Connection..........................................................................2-130
Breakout Panel
Revision 2
Preface
MN/UB530.IOM
iv
About this Manual

This manual provides installation and operation information for the Comtech EF Data
UB-530 Breakout Panel. This a technical document intended for earth station engineers,
technicians, and operators responsible for the operation and maintenance of the breakout
panel.
Conventions and References
Cautions, Warnings, and Important Notes
CAUTION

CAUTION indicates a hazardous situation that, if not avoided, may result in
minor or moderate injury. CAUTION may also be used to indicate other
unsafe practices or risks of property damage.

WARNING

WARNING indicates a potentially hazardous situation that, if not avoided,
could result in death or serious injury.

IMPORTANT

Indicates information critical for proper equipment function.
Metric Conversion
Metric conversion information is located on the inside back cover of this manual. This
information is provided to assist the operator in cross-referencing English to Metric
conversions.
Trademarks
Windows
is a trademark of the Microsoft Corporation.

Other product names mentioned in this manual may be trademarks or registered
trademarks of their respective companies and are hereby acknowledged.
Reporting Comments or Suggestions Concerning this Manual
Comments and suggestions regarding the content and design of this manual will be
appreciated. To submit comments, please contact the Comtech EF Data Technical
Publication Department: techpub@comtechefdata.com Breakout Panel
Revision 2
Preface
MN/UB530.IOM
v
Overview of Changes to Previous Edition
Changes made to Revision 1 include:

General
Changed EIA- to RS- designators.
Removed references to AC/DC power.
Chapter 1
Added reference to Standard 37-pin for RS-422 connector.`
Chapter 2
Revised pin tables.

Electrical Safety
The UB-530 Breakout Panel does not require electrical power nor does it incorporate any
fuses.
Environmental
The breakout panel must not be operated in an environment where the unit is exposed to
extremes of temperature outside the ambient range 0 to 50°C (32° to 122°F),
precipitation, condensation, or humid atmospheres above 95% RH, altitudes (un-
pressurised) greater than 2000 metres, excessive dust or vibration, flammable gases,
corrosive or explosive atmospheres.

Operation in vehicles or other transportable installations that are equipped to provide a
stable environment is permitted. If such vehicles do not provide a stable environment,
safety of the equipment to EN60950 may not be guaranteed.
Installation
Installation:

The installation and connection to the line supply must be made in compliance to local or
national wiring codes and regulations.

International Symbols:

Symbol Definition
Symbol
Definition
~
Alternating Current


Protective Earth

Fuse Chassis Ground
Telecommunications Terminal Equipment Directive Breakout Panel
Revision 2
Preface
MN/UB530.IOM
vi
In accordance with the Telecommunications Terminal Equipment Directive 91/263/EEC,
this equipment should not be directly connected to the Public Telecommunications
Network.
EMC (Electromagnetic Compatibility)
In accordance with European Directive 89/336/EEC, the breakout panel has been shown,
by independent testing, to comply with the following standards:

Emissions:
EN 55022 Class B - Limits and methods of measurement of radio
interference characteristics of Information Technology Equipment.

(Also tested to FCC Part 15 Class B)

Immunity:
EN 50082 Part 1 - Generic immunity standard, Part 1: Domestic,
commercial and light industrial environment.

Additionally, the breakout panel has been shown to comply with the following standards:


EN 61000-3-2
Harmonic Currents Emission
EN 61000-3-3
Voltage Fluctuations and Flicker
EN 61000-4-2
ESD Immunity
EN 61000-4-4
EFT Burst Immunity
EN 61000-4-5
Surge Immunity
EN 61000-4-6
RF Conducted Immunity
EN 61000-4-8
Power frequency Magnetic Field Immunity
EN 61000-4-9
Pulse Magnetic Field Immunity
EN 61000-4-11
Voltage Dips, Interruptions, and Variations Immunity
EN 61000-4-13
Immunity to Harmonics

In order that the breakout panel continues to comply with
these standards, observe the following instructions:


Connections to the transmit and receive IF ports (Type N or Type F connectors)
should be made using a good quality coaxial cable - for example 50
or 75 .

All 'D' type connectors attached to the rear panel must have back-shells that provide
continuous metallic shielding. Cable with a continuous outer shield (either foil or
braid, or both) must be used, and the shield must be bonded to the backshell.

The equipment must be operated with its cover on at all times. If it becomes necessary
to remove the cover, the user should ensure that the cover is correctly re-fitted before
normal operation commences.

IMPORTANT
Breakout Panel
Revision 2
Preface
MN/UB530.IOM
vii
Safety Compliance
EN 60950
This equipment meets the Safety of Information Technology Equipment specification as
defined in EN60950.
Low Voltage Directive (LVD)
The following information is applicable for the European Low Voltage Directive
(EN60950):

<HAR>

Type of power cord required for use in the European Community.
!

CAUTION: Double-pole/Neutral Fusing.
ACHTUNG: Zweipolige bzw. Neutralleiter-Sicherung.

International Symbols:

Symbol Definition

Symbol
Definition

Alternating Current.


Protective Earth.

Fuse.


Chassis Ground.


Note: For additional symbols, refer to Cautions listed earlier in this preface.
Applicable testing is routinely performed as a condition of manufacturing on all units to
ensure compliance with safety requirements of EN60950.
Breakout Panel
Revision 2
Preface
MN/UB530.IOM
viii
Warranty Policy
This Comtech EF Data pro